Network Working Group                                       S. Waldbusser
Request for Comments: 2819                            Lucent Technologies
STD: 59                                                          May 2000
Obsoletes: 1757
Category: Standards Track
        
         Remote Network Monitoring Management Information Base
        

Status of this Memo

このメモの位置付け

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

この文書は、インターネットコミュニティのためのインターネット標準トラックプロトコルを指定し、改善のための議論と提案を要求します。このプロトコルの標準化状態と状態への「インターネット公式プロトコル標準」(STD 1)の最新版を参照してください。このメモの配布は無制限です。

Copyright Notice

著作権表示

Copyright (C) The Internet Society (2000). All Rights Reserved.

著作権(C)インターネット協会(2000)。全著作権所有。

Abstract

抽象

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines objects for managing remote network monitoring devices.

このメモは、TCP / IPベースのインターネットでネットワーク管理プロトコルと共に使用するための管理情報ベース(MIB)の一部を画定します。特に、遠隔ネットワーク監視装置を管理するためにオブジェクトを定義します。

This memo obsoletes RFC 1757. This memo extends that specification by documenting the RMON MIB in SMIv2 format while remaining semantically identical to the existing SMIv1-based MIB.

このメモは、このメモは、既存でSMIv1ベースMIBと意味的に同じままSMIv2の形式でRMON MIBを記録することによって、その仕様を拡張してRFC 1757を時代遅れ。

Table of Contents

目次

   1 The SNMP Management Framework ..............................   2
   2 Overview ...................................................   3
   2.1 Remote Network Management Goals ..........................   4
   2.2 Textual Conventions ......................................   5
   2.3 Structure of MIB .........................................   5
   2.3.1 The Ethernet Statistics Group ..........................   6
   2.3.2 The History Control Group ..............................   6
   2.3.3 The Ethernet History Group .............................   6
   2.3.4 The Alarm Group ........................................   7
   2.3.5 The Host Group .........................................   7
   2.3.6 The HostTopN Group .....................................   7
   2.3.7 The Matrix Group .......................................   7
   2.3.8 The Filter Group .......................................   7
   2.3.9 The Packet Capture Group ...............................   8
   2.3.10 The Event Group .......................................   8
   3 Control of Remote Network Monitoring Devices ...............   8
   3.1  Resource  Sharing  Among Multiple Management Stations ...   9
   3.2 Row Addition Among Multiple Management Stations ..........  10
   4 Conventions ................................................  11
   5 Definitions ................................................  12
   6 Security Considerations ....................................  94
   7 Acknowledgments ............................................  95
   8 Author's Address ...........................................  95
   9 References .................................................  95
   10 Intellectual Property .....................................  97
   11 Full Copyright Statement ..................................  98
        
1. The SNMP Management Framework
1. SNMP管理フレームワーク

The SNMP Management Framework presently consists of five major components:

SNMP Management Frameworkは現在、5つの主要コンポーネントから構成されています。

o An overall architecture, described in RFC 2571 [1].

RFC 2571に記載され、全体的なアーキテクチャ、O [1]。

o Mechanisms for describing and naming objects and events for the purpose of management. The first version of this Structure of Management Information (SMI) is called SMIv1 and described in STD 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4]. The second version, called SMIv2, is described in STD 58, RFC 2578 [5], RFC 2579 [6] and RFC 2580 [7].

管理の目的のためにオブジェクトとイベントを記述し、命名するためのメカニズムO。管理情報(SMI)のこのような構造の最初のバージョンはSTD 16、[2]でSMIv1と呼ばれ、STD 16、RFC 1155に記載され、RFC 1212 [3]及びRFC 1215 [4]。第二のSMIv2と呼ばれるバージョン、STD 58、RFC 2578に記載されている[5]、RFC 2579 [6]およびRFC 2580 [7]。

o Message protocols for transferring management information. The first version of the SNMP message protocol is called SNMPv1 and described in STD 15, RFC 1157 [8]. A second version of the SNMP message protocol, which is not an Internet standards track protocol, is called SNMPv2c and described in RFC 1901 [9] and RFC

管理情報を転送するためのOメッセージプロトコル。 SNMPメッセージプロトコルの最初のバージョンは、[8]のSNMPv1と呼ばれ、STD 15、RFC 1157に記載されています。第二のインターネット標準プロトコルを追跡しないSNMPメッセージプロトコルのバージョン、SNMPv2cのと呼ばれ、RFC 1901年に記載されている[9]及びRFC

1906 [10]. The third version of the message protocol is called SNMPv3 and described in RFC 1906 [10], RFC 2572 [11] and RFC 2574 [12].

1906 [10]。メッセージプロトコルの第三のバージョンのSNMPv3と呼ばれ、RFC 1906年に記載されている[10]、RFC 2572 [11]およびRFC 2574 [12]。

o Protocol operations for accessing management information. The first set of protocol operations and associated PDU formats is described in STD 15, RFC 1157 [8]. A second set of protocol operations and associated PDU formats is described in RFC 1905 [13].

管理情報にアクセスするためのOプロトコル操作。プロトコル操作と関連PDU形式の第一セットは、STD 15、RFC 1157に記載されている[8]。プロトコル操作と関連PDU形式の第2のセットは、RFC 1905 [13]に記載されています。

o A set of fundamental applications described in RFC 2573 [14] and the view-based access control mechanism described in RFC 2575 [15].

O RFC 2573 [14]とビューベースアクセス制御メカニズムに記載の基本的なアプリケーションのセットは、RFC 2575 [15]に記載します。

A more detailed introduction to the current SNMP Management Framework can be found in RFC 2570 [22].

現在のSNMP Management Frameworkへの、より詳細な紹介は、RFC 2570 [22]に記載されています。

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the mechanisms defined in the SMI.

管理対象オブジェクトが仮想情報店を介してアクセスされ、管理情報ベースまたはMIBと呼ばれます。 MIBのオブジェクトは、SMIで定義されたメカニズムを使用して定義されています。

This memo specifies a MIB module that is compliant to the SMIv2. A MIB conforming to the SMIv1 can be produced through the appropriate translations. The resulting translated MIB must be semantically equivalent, except where objects or events are omitted because no translation is possible (use of Counter64). Some machine readable information in SMIv2 will be converted into textual descriptions in SMIv1 during the translation process. However, this loss of machine readable information is not considered to change the semantics of the MIB.

このメモはSMIv2に対応であるMIBモジュールを指定します。 SMIv1に従うMIBは、適切な翻訳を介して製造することができます。得られた翻訳されたMIBには翻訳(Counter64のの使用)が可能ではないので、オブジェクトまたはイベントが省略されている場合を除いて、意味的に等価でなければなりません。 SMIv2のいくつかの機械読み取り可能な情報には、翻訳プロセスの間、SMIv1の原文の記述に変換されます。しかし、機械読み取り可能な情報のこの損失がMIBの意味論を変えると考えられません。

2. Overview
2.概要

Remote network monitoring devices, often called monitors or probes, are instruments that exist for the purpose of managing a network. Often these remote probes are stand-alone devices and devote significant internal resources for the sole purpose of managing a network. An organization may employ many of these devices, one per network segment, to manage its internet. In addition, these devices may be used for a network management service provider to access a client network, often geographically remote.

多くの場合、モニターまたはプローブと呼ばれるリモートネットワーク監視装置は、ネットワークを管理する目的のために存在する機器です。多くの場合、これらのリモートプローブは、スタンドアロン型のデバイスであり、ネットワークを管理する唯一の目的のために重要な内部リソースを割きます。組織は、インターネットを管理するために、ネットワークセグメントごとに、これらのデバイスの多くを使用することができます。また、これらのデバイスは、多くの場合、地理的に離れた、クライアントのネットワークにアクセスするためのネットワーク管理サービスプロバイダのために使用することができます。

The objects defined in this document are intended as an interface between an RMON agent and an RMON management application and are not intended for direct manipulation by humans. While some users may tolerate the direct display of some of these objects, few will tolerate the complexity of manually manipulating objects to accomplish row creation. These functions should be handled by the management application.

この文書で定義されたオブジェクトはRMONエージェントとRMON管理アプリケーションとの間のインターフェースとして意図されており、人間によって直接操作のために意図されていません。一部のユーザーは、これらのオブジェクトのいくつかの直接的な表示を許容できるが、いくつかは、行作成を達成するために、手動で操作するオブジェクトの複雑さを許容します。これらの機能は、管理アプリケーションによって処理されなければなりません。

While most of the objects in this document are suitable for the management of any type of network, there are some which are specific to managing Ethernet networks. These are the objects in the etherStatsTable, the etherHistoryTable, and some attributes of the filterPktStatus and capturBufferPacketStatus objects. The design of this MIB allows similar objects to be defined for other network types. It is intended that future versions of this document and additional documents will define extensions for other network types.

この文書に記載されているオブジェクトのほとんどは、任意のタイプのネットワークの管理に適しているが、イーサネットネットワークの管理に固有のものもあります。これらはetherStatsTableの、etherHistoryTable内のオブジェクト、およびfilterPktStatusのとcapturBufferPacketStatusオブジェクトのいくつかの属性です。このMIBのデザインは、同様のオブジェクトは、他のネットワークタイプのために定義することができます。このドキュメントの将来のバージョンと追加のドキュメントが他のネットワークの種類の拡張子を定義することが意図されています。

There are a number of companion documents to the RMON MIB. The Token Ring RMON MIB [19] provides objects specific to managing Token Ring networks. The RMON-2 MIB [20] extends RMON by providing RMON analysis up to the application layer. The SMON MIB [21] extends RMON by providing RMON analysis for switched networks.

RMON MIBへのコンパニオン文書の数があります。トークンリングRMON MIB [19]トークンリングネットワークを管理する特定のオブジェクトを提供します。 RMON-2 MIB [20]は、アプリケーション層までRMON分析を提供することによって、RMONを拡張します。 SMON MIB [21]交換ネットワークのためのRMON分析を提供することによって、RMONを拡張します。

2.1. Remote Network Management Goals
2.1. リモートネットワーク管理の目標

o Offline Operation There are sometimes conditions when a management station will not be in constant contact with its remote monitoring devices. This is sometimes by design in an attempt to lower communications costs (especially when communicating over a WAN or dialup link), or by accident as network failures affect the communications between the management station and the probe.

オフライン運用O管理ステーションは、その遠隔監視装置との一定の接触しない条件が時々あります。ネットワーク障害は、管理ステーションとプローブとの間の通信に影響を与え、これは(WANまたはダイヤルアップリンクを介して通信する場合は特に)通信コストを低減するための試みで、または偶然に設計することによって時々あります。

        For this reason, this MIB allows a probe to be configured to
        perform diagnostics and to collect statistics continuously, even
        when communication with the management station may not be
        possible or efficient.  The probe may then attempt to notify the
        management station when an exceptional condition occurs.  Thus,
        even in circumstances where communication between management
        station and probe is not continuous, fault, performance, and
        configuration information may be continuously accumulated and
        communicated to the management station conveniently and
        efficiently.
        

o Proactive Monitoring Given the resources available on the monitor, it is potentially helpful for it continuously to run diagnostics and to log network performance. The monitor is always available at the onset of any failure. It can notify the management station of the failure and can store historical statistical information about the failure. This historical information can be played back by the management station in an attempt to perform further diagnosis into the cause of the problem.

O積極的なモニタリングは、モニタ上で利用可能なリソースを考えると、それは継続的に診断を実行すると、ネットワークのパフォーマンスをログに記録するため、それが潜在的に有用です。モニターは、任意の故障の開始時に常に利用可能です。これは、障害の管理ステーションに通知することができ、故障に関する履歴統計情報を格納することができます。この履歴情報は、問題の原因をさらに診断を実行するための試みで、管理ステーションで再生することができます。

o Problem Detection and Reporting The monitor can be configured to recognize conditions, most notably error conditions, and continuously to check for them. When one of these conditions occurs, the event may be logged, and management stations may be notified in a number of ways.

Oの問題の検出と監視の報告が最も顕著な条件、エラー条件を認識するように構成することができ、かつ継続的にそれらをチェックします。これらの条件のいずれかが発生すると、イベントが記録されることがあり、および管理ステーションは、いくつかの方法で通知してもよいです。

o Value Added Data Because a remote monitoring device represents a network resource dedicated exclusively to network management functions, and because it is located directly on the monitored portion of the network, the remote network monitoring device has the opportunity to add significant value to the data it collects. For instance, by highlighting those hosts on the network that generate the most traffic or errors, the probe can give the management station precisely the information it needs to solve a class of problems.

O付加価値データ遠隔監視装置は、ネットワーク管理機能に特化したネットワークリソースを表し、そしてそれは、ネットワークの監視対象部分の上に直接配置されているので、リモートネットワーク監視装置は、データに有意な価値を付加する機会を有しているので収集されます。例えば、ほとんどのトラフィックやエラーを生成するネットワーク上のそれらのホストを強調することで、プローブは正確にそれが問題のクラスを解決するために必要な情報を、管理ステーションを与えることができます。

o Multiple Managers An organization may have multiple management stations for different units of the organization, for different functions (e.g. engineering and operations), and in an attempt to provide disaster recovery. Because environments with multiple management stations are common, the remote network monitoring device has to deal with more than own management station, potentially using its resources concurrently.

O複数のマネージャは、組織は、異なる機能(例えば、エンジニアリングおよび操作)のために、およびディザスタリカバリを提供する試みにおいて、組織の異なる単位のための複数の管理ステーションを有していてもよいです。複数の管理ステーションとの環境が共通しているので、リモートネットワーク監視装置は、潜在的にそのリソースを同時に使用して、独自の管理ステーションよりも多くに対処しなければなりません。

2.2. Textual Conventions
2.2. テキストの表記法

Two new data types are introduced as a textual convention in this MIB document, OwnerString and EntryStatus.

二つの新しいデータ型がこのMIBドキュメント、OwnerStringとEntryStatusでのテキストの表記法として紹介されています。

2.3. Structure of MIB
2.3. MIBの構造

The objects are arranged into the following groups:

オブジェクトは、以下のグループに配置されています。

- ethernet statistics

- イーサネット統計

- history control

- 履歴制御

- ethernet history

- イーサネットの歴史

- alarm

- 警報

- host

- ホスト

- hostTopN

- hostTopN

- matrix

- 行列

- filter

- フィルタ

- packet capture

- パケットキャプチャ

- event

- イベント

These groups are the basic unit of conformance. If a remote monitoring device implements a group, then it must implement all objects in that group. For example, a managed agent that implements the host group must implement the hostControlTable, the hostTable and the hostTimeTable. While this section provides an overview of grouping and conformance information for this MIB, the authoritative reference for such information is contained in the MODULE-COMPLIANCE and OBJECT-GROUP macros later in this MIB.

これらのグループは、適合性の基本的な単位です。遠隔監視装置がグループを実装している場合、それはそのグループ内のすべてのオブジェクトを実装する必要があります。たとえば、ホストのグループを実装し、管理エージェントがhostControlTable、ホストテーブルとホスト時間テーブルを実装する必要があります。このセクションでは、このMIBのグループ化および適合情報の概要を提供するが、そのような情報のための正式の参照は、後でこのMIBのMODULE-COMPLIANCEおよびオブジェクト・グループマクロに含まれています。

All groups in this MIB are optional. Implementations of this MIB must also implement the system group of MIB-II [16] and the IF-MIB [17]. MIB-II may also mandate the implementation of additional groups.

このMIB内のすべてのグループはオプションです。このMIBの実装はまた、MIB-II [16]およびIF-MIB [17]のシステムグループを実装しなければなりません。 MIB-IIはまた、追加のグループの実施を義務付けることがあります。

These groups are defined to provide a means of assigning object identifiers, and to provide a method for implementors of managed agents to know which objects they must implement.

これらのグループは、オブジェクト識別子を割り当てる手段を提供するために、彼らは実装しなければならないどのオブジェクトを知るために、管理エージェントの実装のための方法を提供するために定義されています。

2.3.1. The Ethernet Statistics Group
2.3.1. イーサネット統計グループ

The ethernet statistics group contains statistics measured by the probe for each monitored Ethernet interface on this device. This group consists of the etherStatsTable.

イーサネット統計グループは、このデバイスの監視対象の各イーサネットインターフェイス用のプローブで測定された統計情報が含まれています。このグループはetherStatsTableの構成されています。

2.3.2. The History Control Group
2.3.2. 履歴制御グループ

The history control group controls the periodic statistical sampling of data from various types of networks. This group consists of the historyControlTable.

履歴制御グループは、ネットワークの様々なタイプのデータを定期的に統計的サンプリングを制御します。このグループは、historyControlTableの構成されています。

2.3.3. The Ethernet History Group
2.3.3. イーサネットのHistoryグループ

The ethernet history group records periodic statistical samples from an ethernet network and stores them for later retrieval. This group consists of the etherHistoryTable.

イーサネット履歴グループは、Ethernetネットワークからの定期的な統計サンプルを記録し、後の検索のためにそれらを格納します。このグループは、etherHistoryTableから構成されています。

2.3.4. The Alarm Group
2.3.4. アラームグループ

The alarm group periodically takes statistical samples from variables in the probe and compares them to previously configured thresholds. If the monitored variable crosses a threshold, an event is generated.

アラームグループは、定期的にプローブ内の変数から統計的サンプルを取り、以前に設定したしきい値にそれらを比較します。監視対象の変数がしきい値を超えた場合、イベントが生成されます。

A hysteresis mechanism is implemented to limit the generation of alarms. This group consists of the alarmTable and requires the implementation of the event group.

ヒステリシス機構は、アラームの発生を制限するために実装されています。このグループは、アラームテーブルで構成され、イベントグループの実装を必要とします。

2.3.5. The Host Group
2.3.5. ホストグループ

The host group contains statistics associated with each host discovered on the network. This group discovers hosts on the network by keeping a list of source and destination MAC Addresses seen in good packets promiscuously received from the network. This group consists of the hostControlTable, the hostTable, and the hostTimeTable.

ホストグループは、ネットワーク上で発見された各ホストに関連付けられている統計情報が含まれています。このグループは、無差別にネットワークから受信した良好なパケットで見られるソースおよび宛先MACアドレスのリストを維持することによって、ネットワーク上のホストを発見します。このグループはhostControlTable、ホストテーブル、およびホスト時間テーブルで構成されています。

2.3.6. The HostTopN Group
2.3.6. HostTopNグループ

The hostTopN group is used to prepare reports that describe the hosts that top a list ordered by one of their statistics. The available statistics are samples of one of their base statistics over an interval specified by the management station. Thus, these statistics are rate based. The management station also selects how many such hosts are reported. This group consists of the hostTopNControlTable and the hostTopNTable, and requires the implementation of the host group.

hostTopNグループは、その統計のいずれかによって順序付けられたリストのトップホストを記述する報告書を作成するために使用されます。利用可能な統計は、管理ステーションで指定された間隔でそのベース統計の一つのサンプルです。したがって、これらの統計は、レートベースです。管理ステーションは、多くのそのようなホストが報告されている方法を選択します。このグループはhostTopNControlTableとhostTopNTableで構成され、ホストグループの実装を必要とします。

2.3.7. The Matrix Group
2.3.7. マトリックス・グループ

The matrix group stores statistics for conversations between sets of two addresses. As the device detects a new conversation, it creates a new entry in its tables. This group consists of the matrixControlTable, the matrixSDTable and the matrixDSTable.

二つのアドレスのセット間の会話のための行列グループの店舗統計。デバイスが新しい会話を検出したとして、それは、そのテーブルに新しいエントリを作成します。このグループはmatrixControlTable、matrixSDTable及びますmatrixDSTableで構成されています。

2.3.8. The Filter Group
2.3.8. フィルタグループ

The filter group allows packets to be matched by a filter equation. These matched packets form a data stream that may be captured or may generate events. This group consists of the filterTable and the channelTable.

フィルタ群は、パケットがフィルタ式にマッチすることを可能にします。これらの一致したパケットを捕捉することができるか、イベントを生成することができるデータ・ストリームを形成します。このグループはfilterTableとchannelTableで構成されています。

2.3.9. The Packet Capture Group
2.3.9. パケットキャプチャグループ

The Packet Capture group allows packets to be captured after they flow through a channel. This group consists of the bufferControlTable and the captureBufferTable, and requires the implementation of the filter group.

パケットキャプチャグループは、それらがチャネルを通って流れた後にパケットが捕捉されることを可能にします。このグループはbufferControlTableとcaptureBufferTableからなり、フィルタ・グループの実装を必要とします。

2.3.10. The Event Group
2.3.10. イベントグループ

The event group controls the generation and notification of events from this device. This group consists of the eventTable and the logTable.

イベント・グループは、このデバイスからのイベントの生成と通知を制御します。このグループは、イベントテーブルとログ表から構成されています。

3. Control of Remote Network Monitoring Devices
リモートネットワーク監視装置の3.コントロール

Due to the complex nature of the available functions in these devices, the functions often need user configuration. In many cases, the function requires parameters to be set up for a data collection operation. The operation can proceed only after these parameters are fully set up.

これらのデバイスで利用可能な機能の複雑な性質のために、機能が多くの場合、ユーザ設定を必要とします。多くの場合、関数は、データ収集動作のために設定すべきパラメータが必要です。操作は、これらのパラメータが完全に設定された後にのみ進むことができます。

Many functional groups in this MIB have one or more tables in which to set up control parameters, and one or more data tables in which to place the results of the operation. The control tables are typically read-write in nature, while the data tables are typically read-only. Because the parameters in the control table often describe resulting data in the data table, many of the parameters can be modified only when the control entry is invalid. Thus, the method for modifying these parameters is to invalidate the control entry, causing its deletion and the deletion of any associated data entries, and then create a new control entry with the proper parameters. Deleting the control entry also gives a convenient method for reclaiming the resources used by the associated data.

このMIBの多くの官能基は、一つ以上の制御パラメータを設定するには、テーブル、および1つまたは操作の結果を配置する複数のデータテーブルを持っています。制御テーブルは、一般的に読み書きされている自然の中を、データテーブルは、通常、読み取り専用されています。制御テーブルのパラメータは、多くの場合、データテーブルに結果のデータを記述するので、パラメータの多くは、制御エントリが無効である場合にのみ変更することができます。したがって、これらのパラメータを変更するための方法は、欠失および任意の関連データ項目の削除を引き起こし、制御エントリを無効化し、その後適切なパラメータで新しい制御エントリを作成することです。制御エントリを削除すると、関連するデータが使用するリソースを取り戻すための便利な方法を提供します。

Some objects in this MIB provide a mechanism to execute an action on the remote monitoring device. These objects may execute an action as a result of a change in the state of the object. For those objects in this MIB, a request to set an object to the same value as it currently holds would thus cause no action to occur.

このMIBの一部のオブジェクトは、遠隔監視装置にアクションを実行するための機構を提供します。これらのオブジェクトは、オブジェクトの状態の変化の結果としてアクションを実行することができます。このMIBでそれらのオブジェクトの場合は、それが現在保持している値と同じ値にオブジェクトを設定するための要求は、このように何もアクションが起こらないように原因となります。

To facilitate control by multiple managers, resources have to be shared among the managers. These resources are typically the memory and computation resources that a function requires.

複数のマネージャによって制御を容易にするために、リソースは、管理者間で共有する必要があります。これらのリソースは通常、関数が必要とメモリと計算資源です。

3.1. Resource Sharing Among Multiple Management Stations
3.1. 複数の管理ステーション間のリソースの共有

When multiple management stations wish to use functions that compete for a finite amount of resources on a device, a method to facilitate this sharing of resources is required. Potential conflicts include:

複数の管理ステーションは、デバイス上のリソースの有限量を競うの機能を使用したい場合は、このリソースの共有を容易にするための方法が必要です。潜在的な競合が含まれます:

o Two management stations wish to simultaneously use resources that together would exceed the capability of the device. o A management station uses a significant amount of resources for a long period of time. o A management station uses resources and then crashes, forgetting to free the resources so others may use them.

O 2つの管理ステーションは、同時に一緒にデバイスの能力を超えてしまうのリソースを使用したいです。 O管理ステーションは、時間の長い期間のためのリソースを大量に使用しています。 O管理ステーションはリソースを使用して、他の人がそれらを使用することができますように、リソースを解放するために忘れて、クラッシュします。

A mechanism is provided for each management station initiated function in this MIB to avoid these conflicts and to help resolve them when they occur. Each function has a label identifying the initiator (owner) of the function. This label is set by the initiator to provide for the following possibilities:

メカニズムは、これらの競合を避けるために、彼らが発生したときにそれらを解決するために、このMIBで機能を開始し、各管理ステーションのために提供されます。各関数は、関数の開始剤(所有者)を識別するラベルを有します。このラベルは、以下の可能性を提供するために、イニシエータによって設定されます。

o A management station may recognize resources it owns and no longer needs. o A network operator can find the management station that owns the resource and negotiate for it to be freed. o A network operator may decide to unilaterally free resources another network operator has reserved. o Upon initialization, a management station may recognize resources it had reserved in the past. With this information it may free the resources if it no longer needs them.

O管理ステーションは、それが所有しているリソースと、もはや必要性を認識することができます。 Oネットワークオペレータは、リソースを所有している管理ステーションを見つけ、それが解放されるために交渉することができます。 Oネットワークオペレータは、別のネットワークオペレータが予約した一方的にリソースを解放するように決定することができます。 O初期化時に、管理ステーションは、それが過去に予約していたリソースを認識することができます。それは、もはやそれらを必要とする場合は、この情報を使えば、リソースを解放しないことがあります。

Management stations and probes should support any format of the owner string dictated by the local policy of the organization. It is suggested that this name contain one or more of the following: IP address, management station name, network manager's name, location, or phone number. This information will help users to share the resources more effectively.

管理ステーションおよびプローブは、組織のローカルポリシーによって決定所有者文字列のいずれかの形式をサポートする必要があります。 IPアドレス、管理局名、ネットワーク管理者の名前、場所、または電話番号:この名前は、次の一つ以上を含んでいることを示唆しています。この情報は、ユーザーがより効率的にリソースを共有するのに役立ちます。

There is often default functionality that the device or the administrator of the probe (often the network administrator) wishes to set up. The resources associated with this functionality are then owned by the device itself or by the network administrator, and are intended to be long-lived. In this case, the device or the administrator will set the relevant owner object to a string starting with 'monitor'. Indiscriminate modification of the monitor-owned configuration by network management stations is discouraged. In fact, a network management station should only modify these objects under the direction of the administrator of the probe.

デバイスまたはプローブ(多くの場合、ネットワーク管理者)の管理者が設定したいデフォルトの機能がしばしばあります。この機能に関連付けられているリソースは、デバイス自体によって、またはネットワーク管理者によって所有され、かつ長寿命であることを意図しています。この場合には、デバイスまたは管理者が「モニタ」で始まる文字列に関連する所有者オブジェクトを設定します。ネットワーク管理ステーションによってモニターが所有するコンフィギュレーションの無差別変更はお勧めしません。実際には、ネットワーク管理ステーションは、プローブの管理者の指示の下でこれらのオブジェクトを変更する必要があります。

Resources on a probe are scarce and are typically allocated when control rows are created by an application. Since many applications may be using a probe simultaneously, indiscriminate allocation of resources to particular applications is very likely to cause resource shortages in the probe.

プローブ上のリソースが不足していると制御行がアプリケーションによって作成されたとき、典型的に割り当てられています。多くのアプリケーションが同時にプローブを使用している場合がありますので、特定のアプリケーションへのリソースの無差別配分は、プローブ内のリソース不足を引き起こす可能性が非常に高いです。

When a network management station wishes to utilize a function in a monitor, it is encouraged to first scan the control table of that function to find an instance with similar parameters to share. This is especially true for those instances owned by the monitor, which can be assumed to change infrequently. If a management station decides to share an instance owned by another management station, it should understand that the management station that owns the instance may indiscriminately modify or delete it.

ネットワーク管理ステーションは、モニタに機能を利用したい場合には、第1の類似のパラメータが共有するとインスタンスを見つけるために、その機能の制御テーブルをスキャンすることが推奨されます。仮定することができるモニターが所有するそれらのインスタンスは、まれにしか変更するために、これは特にそうです。管理ステーションは、別の管理ステーションが所有するインスタンスを共有することを決定した場合、それはインスタンスを所有している管理ステーションが無差別にそれを変更したり、削除し得ることを理解すべきです。

It should be noted that a management application should have the most trust in a monitor-owned row because it should be changed very infrequently. A row owned by the management application is less long-lived because a network administrator is more likely to re-assign resources from a row that is in use by one user than from a monitor-owned row that is potentially in use by many users. A row owned by another application would be even less long-lived because the other application may delete or modify that row completely at its discretion.

非常にまれにしか変更されなければならないので、管理アプリケーションは、モニターが所有する行の中で最も信頼を持つべきであることに留意すべきです。ネットワーク管理者は、多くのユーザーが使用して潜在的にあるモニターが所有する行からよりも、一人のユーザーによって使用されている行から再割り当てるリソースへの可能性が高いので、管理アプリケーションによって所有された行は、あまり長寿命です。他のアプリケーションは、完全にその裁量で、その行を削除または修正することができるので、他のアプリケーションが所有する行があっても少ない長寿命であろう。

3.2. Row Addition Among Multiple Management Stations
3.2. 複数の管理ステーションの中で列付加

The addition of new rows is achieved using the method described in RFC 1905 [13]. In this MIB, rows are often added to a table in order to configure a function. This configuration usually involves parameters that control the operation of the function. The agent must check these parameters to make sure they are appropriate given restrictions defined in this MIB as well as any implementation specific restrictions such as lack of resources. The agent implementor may be confused as to when to check these parameters and when to signal to the management station that the parameters are invalid. There are two opportunities:

新しい行の追加は、RFC 1905 [13]に記載の方法を用いて達成されます。このMIBでは、行は、多くの場合、機能を設定するには、次の表に追加されます。この構成は、通常機能の動作を制御するパラメータを含んでいます。エージェントは、これらのパラメータは、彼らがこのMIBで定義された適切な特定の制限だけでなく、そのようなリソースの不足など任意の実装固有の制限があることを確認するチェックしなければなりません。エージェントの実装は、これらのパラメータをチェックするときに、いつパラメータが無効であることを管理ステーションに信号にと混同されてもよいです。 2つの機会があります。

o When the management station sets each parameter object.

O管理ステーションは、各パラメータのオブジェクトを設定します。

o When the management station sets the entry status object to valid.

O管理ステーションは、有効にエントリステータスオブジェクトを設定する場合。

If the latter is chosen, it would be unclear to the management station which of the several parameters was invalid and caused the badValue error to be emitted. Thus, wherever possible, the implementor should choose the former as it will provide more information to the management station.

後者が選択される場合、それは無効であり、エラーBadValueが放出される原因となったいくつかのパラメータの管理ステーションに不明であろう。それは管理ステーションへのより多くの情報を提供するようこのように、可能な限り、実装者は元を選択する必要があります。

A problem can arise when multiple management stations attempt to set configuration information simultaneously using SNMP. When this involves the addition of a new conceptual row in the same control table, the managers may collide, attempting to create the same entry. To guard against these collisions, each such control entry contains a status object with special semantics that help to arbitrate among the managers. If an attempt is made with the row addition mechanism to create such a status object and that object already exists, an error is returned. When more than one manager simultaneously attempts to create the same conceptual row, only the first can succeed. The others will receive an error.

複数の管理ステーションは、SNMPを使用して同時に設定情報を設定しようとすると問題が発生する可能性があります。これは、同じ制御テーブル内の新しい概念的な行の追加を伴う場合、管理者は、同一のエントリを作成しようとし、衝突してもよいです。これらの衝突を防ぐために、各そのような制御エントリは、経営者の間で仲裁するのに役立ち、特別なセマンティクスを持つステータスオブジェクトが含まれています。試みが、このような状況オブジェクトを作成する行加算機構で作られ、そのオブジェクトが既に存在する場合、エラーが返されます。複数の管理者が同時に同じ概念的な列を作成しようとすると、最初は成功することができます。他の人はエラーが発生します。

When a manager wishes to create a new control entry, it needs to choose an index for that row. It may choose this index in a variety of ways, hopefully minimizing the chances that the index is in use by another manager. If the index is in use, the mechanism mentioned previously will guard against collisions. Examples of schemes to choose index values include random selection or scanning the control table looking for the first unused index. Because index values may be any valid value in the range and they are chosen by the manager, the agent must allow a row to be created with any unused index value if it has the resources to create a new row.

管理者は新しい制御エントリを作成したい場合は、その行のインデックスを選択する必要があります。これは、うまくいけば、インデックスは、別のマネージャで使用されている可能性を最小限に抑え、さまざまな方法でこのインデックスを選択することができます。インデックスが使用されている場合は、先に述べたメカニズムは、衝突を防ぐだろう。インデックス値を選択する方式の例としては、ランダム選択または最​​初の未使用のインデックスを探している制御テーブルをスキャンが含まれます。インデックス値が範囲内の任意の有効な値であってもよいし、それらが管理者によって選ばれているので、それは新しい行を作成するためのリソースを持っている場合、エージェントは行が未使用のインデックス値を使用して作成することを可能にする必要があります。

Some tables in this MIB reference other tables within this MIB. When creating or deleting entries in these tables, it is generally allowable for dangling references to exist. There is no defined order for creating or deleting entries in these tables.

このMIB内のこのMIBの参照他のテーブルの一部のテーブル。これらのテーブルのエントリを作成または削除すると、それが存在するの参照をダングリングのための一般的に許容されます。これらのテーブルのエントリを作成または削除のための定義された順序はありません。

4. Conventions
4.表記

The following conventions are used throughout the RMON MIB and its companion documents.

次の規則は、RMON MIBとその仲間ドキュメント全体で使用されています。

Good Packets

グッドパケット

Good packets are error-free packets that have a valid frame length. For example, on Ethernet, good packets are error-free packets that are between 64 octets long and 1518 octets long. They follow the form defined in IEEE 802.3 section 3.2.all.

グッドパケットが有効なフレームの長さを持っているエラーのないパケットです。たとえば、イーサネット上で、良いパケットは64個のオクテット長と1518オクテット長い間されているエラーのないパケットがあります。彼らは、IEEE 802.3セクション3.2.allで定義された形式に従ってください。

Bad Packets

不良パケット

Bad packets are packets that have proper framing and are therefore recognized as packets, but contain errors within the packet or have an invalid length. For example, on Ethernet, bad packets have a valid preamble and SFD, but have a bad CRC, or are either shorter than 64 octets or longer than 1518 octets.

悪いパケットは適切なフレーミングを持っているので、パケットとして認識されているが、パケット内のエラーが含まれているか、無効な長さを持つパケットです。たとえば、イーサネット上で、不正なパケットは1518オクテットより長いより短い64オクテットかのいずれかを有効プリアンブルとSFDを持っていますが、悪いCRCを持っている、またはされています。

5. Definitions
5.定義
 RMON-MIB DEFINITIONS ::= BEGIN
        
     IMPORTS
         MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
         NOTIFICATION-TYPE, mib-2, Counter32,
         Integer32, TimeTicks                   FROM SNMPv2-SMI
        

TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC

SNMPv2の-TC FROM DisplayStringのTEXTUAL-CONVENTION、

MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF;

MODULE-COMPLIANCE、OBJECT-GROUP、NOTIFICATION-GROUPのSNMPv2-CONF FROM;

-- Remote Network Monitoring MIB

- リモートネットワーク監視MIB

rmonMibModule MODULE-IDENTITY LAST-UPDATED "200005110000Z" -- 11 May, 2000 ORGANIZATION "IETF RMON MIB Working Group" CONTACT-INFO "Steve Waldbusser Phone: +1-650-948-6500 Fax: +1-650-745-0671 Email: waldbusser@nextbeacon.com" DESCRIPTION "Remote network monitoring devices, often called monitors or probes, are instruments that exist for the purpose of managing a network. This MIB defines objects for managing remote network monitoring devices."

rmonMibModuleのMODULE-IDENTITY LAST-UPDATED "200005110000Z" - 2000年5月11日ORGANIZATION "IETF RMON MIBワーキンググループ" CONTACT-INFO「スティーブWaldbusser電話:+ 1-650-948-6500ファックス:+ 1-650-745-0671メール:多くの場合、モニターまたはプローブと呼ばれるwaldbusser@nextbeacon.com」説明 『リモートネットワーク監視装置は、ネットワークを管理する目的のために存在する機器である。このMIBは、リモートネットワーク監視デバイスを管理するためにオブジェクトを定義します』。。

     REVISION "200005110000Z"    -- 11 May, 2000
     DESCRIPTION
         "Reformatted into SMIv2 format.
        

This version published as RFC 2819."

このバージョンでは、「RFC 2819として公開します

REVISION "199502010000Z" -- 1 Feb, 1995 DESCRIPTION "Bug fixes, clarifications and minor changes based on implementation experience, published as RFC1757 [18].

REVISION "199502010000Z" - 1995年2月1日DESCRIPTION「バグ修正、明確化およびRFC1757として公開実装経験に基づいて、多少の変更[18]。

Two changes were made to object definitions:

2つの変更オブジェクト定義するために行われました。

1) A new status bit has been defined for the captureBufferPacketStatus object, indicating that the packet order within the capture buffer may not be identical to the packet order as received off the wire. This bit may only be used for packets transmitted by the probe. Older NMS applications can safely ignore this status bit, which might be used by newer agents.

1)新しいステータスビットは、ワイヤをオフに受信したキャプチャバッファ内のパケット順序は、パケットの順序と同一ではないかもしれないことを示す、captureBufferPacketStatusオブジェクトに対して定義されています。このビットは、プローブによって送信されたパケットのために使用することができます。古いNMSアプリケーションは安全に、より新しいエージェントによって使用されるかもしれない。この状態ビットを、無視することができます。

2) The packetMatch trap has been removed. This trap was never actually 'approved' and was not added to this document along with the risingAlarm and fallingAlarm traps. The packetMatch trap could not be throttled, which could cause disruption of normal network traffic under some circumstances. An NMS should configure a risingAlarm threshold on the appropriate channelMatches instance if a trap is desired for a packetMatch event. Note that logging of packetMatch events is still supported--only trap generation for such events has been removed.

2)packetMatchトラップが除去されています。このトラップは、実際には「承認されていない」んでしたし、risingAlarmととfallingAlarmトラップと一緒に、このドキュメントに追加されませんでした。 packetMatchトラップは、いくつかの状況下では、通常のネットワークトラフィックの中断を引き起こす可能性がある、絞ることができませんでした。トラップがpacketMatchイベントのために望まれる場合NMSは適切なchannelMatchesインスタンス上risingAlarmしきい値を設定すべきです。 packetMatchイベントのロギングをまだサポートされていることに注意してください - このようなイベントのためにのみトラップ生成は削除されました。

In addition, several clarifications to individual object definitions have been added to assist agent and NMS implementors:

また、個々のオブジェクト定義には、いくつかの明確化は、エージェントとNMS実装を支援するために追加されました。

- global definition of 'good packets' and 'bad packets'

- 「良いパケット」と「不良パケット」のグローバル定義

- more detailed text governing conceptual row creation and modification

- 概念的な列の作成と変更を管理するより詳細なテキスト

- instructions for probes relating to interface changes and disruptions

- 変更および中断のインターフェイスに関連するプローブのための説明書

- clarification of some ethernet counter definitions

- いくつかのイーサネットカウンタの定義の明確化

- recommended formula for calculating network utilization

- ネットワークの使用率を計算するための推奨式

- clarification of channel and captureBuffer behavior for some unusual conditions

- いくつかの異常な状態のためのチャネルとcaptureBufferの挙動の解明

- examples of proper instance naming for each table"

- 適切なインスタンスの例としては、「テーブルごとに命名します

     REVISION "199111010000Z"    -- 1 Nov, 1991
     DESCRIPTION
         "The original version of this MIB, published as RFC1271."
     ::= { rmonConformance 8 }
        
     rmon    OBJECT IDENTIFIER ::= { mib-2 16 }
        

-- textual conventions

- テキストの表記法

 OwnerString ::= TEXTUAL-CONVENTION
     STATUS current
        
     DESCRIPTION
         "This data type is used to model an administratively
         assigned name of the owner of a resource. Implementations
         must accept values composed of well-formed NVT ASCII
         sequences. In addition, implementations should accept
         values composed of well-formed UTF-8 sequences.
        
         It is suggested that this name contain one or more of
         the following: IP address, management station name,
         network manager's name, location, or phone number.
         In some cases the agent itself will be the owner of
         an entry.  In these cases, this string shall be set
         to a string starting with 'monitor'.
        

SNMP access control is articulated entirely in terms of the contents of MIB views; access to a particular SNMP object instance depends only upon its presence or absence in a particular MIB view and never upon its value or the value of related object instances. Thus, objects of this type afford resolution of resource contention only among cooperating managers; they realize no access control function with respect to uncooperative parties." SYNTAX OCTET STRING (SIZE (0..127))

SNMPアクセス制御は、MIBビューの内容の面で完全に関節結合されます。特定のSNMPオブジェクトのインスタンスへのアクセスは、特定のMIBビューで、決してその価値または関連するオブジェクトインスタンスの値にその存在または不存在に依存します。したがって、このタイプのオブジェクトは、協働マネージャー間のリソースの競合の解決を与えます。彼らは非協力的な関係者に関して一切のアクセス制御機能を実現していない。」構文オクテットSTRING(SIZE(0..127))

 EntryStatus ::= TEXTUAL-CONVENTION
     STATUS current
     DESCRIPTION
         "The status of a table entry.
        
         Setting this object to the value invalid(4) has the
         effect of invalidating the corresponding entry.
         That is, it effectively disassociates the mapping
         identified with said entry.
         It is an implementation-specific matter as to whether
         the agent removes an invalidated entry from the table.
         Accordingly, management stations must be prepared to
         receive tabular information from agents that corresponds
         to entries currently not in use.  Proper
         interpretation of such entries requires examination
         of the relevant EntryStatus object.
        

An existing instance of this object cannot be set to createRequest(2). This object may only be set to createRequest(2) when this instance is created. When this object is created, the agent may wish to create supplemental object instances with default values to complete a conceptual row in this table. Because the creation of these default objects is entirely at the option of the agent, the manager must not assume that any will be created, but may make use of any that are created. Immediately after completing the create operation, the agent must set this object to underCreation(3).

このオブジェクトの既存のインスタンスは、createRequest(2)に設定することができません。このインスタンスが作成されるとき、このオブジェクトはcreateRequest(2)に設定してもよいです。このオブジェクトが作成されると、エージェントはこの表の概念的な列を完了するために、デフォルト値で補足オブジェクトのインスタンスを作成することを望むかもしれません。これらのデフォルトオブジェクトの作成は完全にエージェントのオプションであるため、管理者は、任意のが作成されると仮定してはいけませんが、作成される任意のものを利用してもよいです。すぐに作成操作が完了した後に、エージェントはのunderCreation(3)にこのオブジェクトを設定する必要があります。

When in the underCreation(3) state, an entry is allowed to exist in a possibly incomplete, possibly inconsistent state, usually to allow it to be modified in multiple PDUs. When in this state, an entry is not fully active. Entries shall exist in the underCreation(3) state until the management station is finished configuring the entry and sets this object to valid(1) or aborts, setting this object to invalid(4). If the agent determines that an entry has been in the underCreation(3) state for an abnormally long time, it may decide that the management station has crashed. If the agent makes this decision, it may set this object to invalid(4) to reclaim the entry. A prudent agent will understand that the management station may need to wait for human input and will allow for that possibility in its determination of this abnormally long period.

underCreation(3)状態で、エントリーは、それが複数のPDUに変更することができるように、通常、おそらく不完全、おそらく一貫性のない状態で存在するときに許可されます。この状態では、エントリは完全にアクティブではありません。管理ステーションは、このオブジェクトが有効に進入し、セットの構成が完了(1)又は中止し、(4)無効にするには、このオブジェクトを設定するまでエントリがのunderCreation(3)状態で存在しなければなりません。エージェントはエントリが異常に長時間のunderCreation(3)状態にあったと判断した場合には、管理ステーションがクラッシュしたことを決定することができます。エージェントがこの決定をしたときは、(4)のエントリを再利用するために、無効にこのオブジェクトを設定することがあります。慎重なエージェントは、管理ステーションは、人間の入力を待つ必要があるかもしれないと、この異常に長い期間のその決意でその可能性を可能にすることを理解するであろう。

An entry in the valid(1) state is fully configured and consistent and fully represents the configuration or operation such a row is intended to represent. For example, it could be a statistical function that is configured and active, or a filter that is available in the list of filters processed by the packet capture process.

有効な(1)状態のエントリは、完全に構成され、一貫して完全に構成又は行を表すことを意図している操作を表します。例えば、構成、アクティブされる統計関数、またはパケットキャプチャプロセスによって処理されたフィルタのリストで利用可能であるフィルタであってもよいです。

A manager is restricted to changing the state of an entry in the following ways:

管理者は、次の方法でエントリの状態を変更することに制限されています。

To: valid createRequest underCreation invalid From: valid OK NO OK OK createRequest N/A N/A N/A N/A underCreation OK NO OK OK invalid NO NO NO OK nonExistent NO OK NO OK

To:有効なcreateRequestのunderCreation無効から有効なOK NO OK OK createRequest N / A N / A N / A N / AのunderCreation OK NO OK OKがOK NO OK NO OK、存在しないNO NO NO無効

In the table above, it is not applicable to move the state from the createRequest state to any other state because the manager will never find the variable in that state. The nonExistent state is not a value of the enumeration, rather it means that the entryStatus variable does not exist at all.

上記の表では、管理者がその状態で変数を見つけることはありませんので、他の状態にcreateRequest状態から状態を移動するために適用されていません。存在しない状態ではなく、それがentryStatus変数が全く存在しないことを意味し、列挙の値ではありません。

An agent may allow an entryStatus variable to change state in additional ways, so long as the semantics of the states are followed. This allowance is made to ease the implementation of the agent and is made despite the fact that managers should never exercise these additional state transitions." SYNTAX INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) }

エージェントはentryStatus変数は限り状態のセマンティクスに従っているとして、追加的な方法で状態を変更することを可能にします。この引当金は、エージェントの実装を容易にするために作られており、管理者はこれらの追加状態遷移を行使してはならないという事実にもかかわらず行われている。」SYNTAX INTEGER {有効(1)、createRequest(2)、のunderCreation(3)、無効(4) }

     statistics        OBJECT IDENTIFIER ::= { rmon 1 }
     history           OBJECT IDENTIFIER ::= { rmon 2 }
     alarm             OBJECT IDENTIFIER ::= { rmon 3 }
     hosts             OBJECT IDENTIFIER ::= { rmon 4 }
     hostTopN          OBJECT IDENTIFIER ::= { rmon 5 }
     matrix            OBJECT IDENTIFIER ::= { rmon 6 }
     filter            OBJECT IDENTIFIER ::= { rmon 7 }
     capture           OBJECT IDENTIFIER ::= { rmon 8 }
     event             OBJECT IDENTIFIER ::= { rmon 9 }
     rmonConformance   OBJECT IDENTIFIER ::= { rmon 20 }
        

-- The Ethernet Statistics Group -- -- Implementation of the Ethernet Statistics group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The ethernet statistics group contains statistics measured by the -- probe for each monitored interface on this device. These -- statistics take the form of free running counters that start from -- zero when a valid entry is created. -- -- This group currently has statistics defined only for -- Ethernet interfaces. Each etherStatsEntry contains statistics -- for one Ethernet interface. The probe must create one -- etherStats entry for each monitored Ethernet interface -- on the device.

- イーサネット統計グループ - - イーサネット統計グループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - このデバイスの各モニターインターフェースのためのプローブ - イーサネット統計グループは、によって測定統計情報を含んでいます。これらの - 有効なエントリが作成されたときに、ゼロ - 統計から開始するフリーランニングカウンターの形をとります。 - - イーサネットインターフェイス - このグループは、現在だけのために定義された統計情報を持っています。 1つのイーサネットインターフェイス用 - 各etherStatsEntryは、統計が含まれています。プローブは、1を作成する必要があります - 各監視対象イーサネットインターフェイスのetherStatsをエントリ - デバイス上で。

 etherStatsTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF EtherStatsEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of Ethernet statistics entries."
     ::= { statistics 1 }
        
 etherStatsEntry OBJECT-TYPE
     SYNTAX     EtherStatsEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A collection of statistics kept for a particular
         Ethernet interface.  As an example, an instance of the
         etherStatsPkts object might be named etherStatsPkts.1"
     INDEX { etherStatsIndex }
     ::= { etherStatsTable 1 }
        
 EtherStatsEntry ::= SEQUENCE {
     etherStatsIndex                    Integer32,
     etherStatsDataSource               OBJECT IDENTIFIER,
     etherStatsDropEvents               Counter32,
     etherStatsOctets                   Counter32,
     etherStatsPkts                     Counter32,
     etherStatsBroadcastPkts            Counter32,
     etherStatsMulticastPkts            Counter32,
     etherStatsCRCAlignErrors           Counter32,
     etherStatsUndersizePkts            Counter32,
     etherStatsOversizePkts             Counter32,
     etherStatsFragments                Counter32,
     etherStatsJabbers                  Counter32,
     etherStatsCollisions               Counter32,
     etherStatsPkts64Octets             Counter32,
     etherStatsPkts65to127Octets        Counter32,
     etherStatsPkts128to255Octets       Counter32,
     etherStatsPkts256to511Octets       Counter32,
     etherStatsPkts512to1023Octets      Counter32,
     etherStatsPkts1024to1518Octets     Counter32,
     etherStatsOwner                    OwnerString,
     etherStatsStatus                   EntryStatus
 }
        
 etherStatsIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of this object uniquely identifies this
         etherStats entry."
     ::= { etherStatsEntry 1 }
        

etherStatsDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current

etherStatsDataSourceのOBJECT-TYPE構文オブジェクト識別子MAX-ACCESSはリード作成しますステータス現在

     DESCRIPTION
         "This object identifies the source of the data that
         this etherStats entry is configured to analyze.  This
         source can be any ethernet interface on this device.
         In order to identify a particular interface, this object
         shall identify the instance of the ifIndex object,
         defined in RFC 2233 [17], for the desired interface.
         For example, if an entry were to receive data from
         interface #1, this object would be set to ifIndex.1.
        
         The statistics in this group reflect all packets
         on the local network segment attached to the identified
         interface.
        

An agent may or may not be able to tell if fundamental changes to the media of the interface have occurred and necessitate an invalidation of this entry. For example, a hot-pluggable ethernet card could be pulled out and replaced by a token-ring card. In such a case, if the agent has such knowledge of the change, it is recommended that it invalidate this entry.

エージェントは、インタフェースのメディアに対する基本的な変更が発生した場合は教えてくれと、このエントリの無効化を必要とすることができない可能性があります。例えば、ホットプラグ対応のイーサネットカードを引き抜くことができ、トークンリングカードに置き換えます。エージェントが変更のような知識を持っている場合、このような場合には、それは、このエントリを無効にすることをお勧めします。

         This object may not be modified if the associated
         etherStatsStatus object is equal to valid(1)."
     ::= { etherStatsEntry 2 }
        
 etherStatsDropEvents OBJECT-TYPE
     SYNTAX     Counter32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of events in which packets
         were dropped by the probe due to lack of resources.
         Note that this number is not necessarily the number of
         packets dropped; it is just the number of times this
         condition has been detected."
     ::= { etherStatsEntry 3 }
        

etherStatsOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets).

etherStatsOctets OBJECT-TYPE SYNTAXカウンタユニット「オクテット」MAX-ACCESS read-only説明は「(悪いパケットにおけるものを含む)データのオクテットの総数(フレーミングビットを除くが、FCSオクテットを含む)をネットワーク上で受信されました。

         This object can be used as a reasonable estimate of
         10-Megabit ethernet utilization.  If greater precision is
         desired, the etherStatsPkts and etherStatsOctets objects
         should be sampled before and after a common interval.  The
         differences in the sampled values are Pkts and Octets,
         respectively, and the number of seconds in the interval is
         Interval.  These values are used to calculate the Utilization
         as follows:
        
                          Pkts * (9.6 + 6.4) + (Octets * .8)
          Utilization = -------------------------------------
                                  Interval * 10,000
        
         The result of this equation is the value Utilization which
         is the percent utilization of the ethernet segment on a
         scale of 0 to 100 percent."
     ::= { etherStatsEntry 4 }
        
 etherStatsPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad packets,
         broadcast packets, and multicast packets) received."
     ::= { etherStatsEntry 5 }
        
 etherStatsBroadcastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of good packets received that were
         directed to the broadcast address.  Note that this
         does not include multicast packets."
     ::= { etherStatsEntry 6 }
        
 etherStatsMulticastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of good packets received that were
         directed to a multicast address.  Note that this number
         does not include packets directed to the broadcast address."
     ::= { etherStatsEntry 7 }
        
 etherStatsCRCAlignErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets received that
         had a length (excluding framing bits, but
         including FCS octets) of between 64 and 1518
         octets, inclusive, but had either a bad
         Frame Check Sequence (FCS) with an integral
         number of octets (FCS Error) or a bad FCS with
         a non-integral number of octets (Alignment Error)."
     ::= { etherStatsEntry 8 }
        
 etherStatsUndersizePkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets received that were
         less than 64 octets long (excluding framing bits,
         but including FCS octets) and were otherwise well
         formed."
     ::= { etherStatsEntry 9 }
        
 etherStatsOversizePkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets received that were
         longer than 1518 octets (excluding framing bits,
         but including FCS octets) and were otherwise
         well formed."
     ::= { etherStatsEntry 10 }
        

etherStatsFragments OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION

etherStatsFragmentsのOBJECT-TYPE SYNTAX Counter32ユニット "パケット" MAX-ACCESS read-onlyステータス現在の説明

         "The total number of packets received that were less than
         64 octets in length (excluding framing bits but including
         FCS octets) and had either a bad Frame Check Sequence
         (FCS) with an integral number of octets (FCS Error) or a
         bad FCS with a non-integral number of octets (Alignment
         Error).
        
         Note that it is entirely normal for etherStatsFragments to
         increment.  This is because it counts both runts (which are
         normal occurrences due to collisions) and noise hits."
     ::= { etherStatsEntry 11 }
        

etherStatsJabbers OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

etherStatsJabbers OBJECT-TYPE SYNTAX Counter32ユニット「パケット」MAX-ACCESS read-onlyステータス現在の説明「パケットの総数は長い1518個のオクテット(フレーミングビットを除くが、FCSオクテットは含む)よりもあったが、どちらか悪いフレーム・チェックを持っていた受信しましたオクテットの整数(FCSエラー)またはオクテットの非整数(アラインメントエラー)との悪いFCSを持つシーケンス(FCS)。

         Note that this definition of jabber is different
         than the definition in IEEE-802.3 section 8.2.1.5
         (10BASE5) and section 10.3.1.4 (10BASE2).  These
         documents define jabber as the condition where any
         packet exceeds 20 ms.  The allowed range to detect
         jabber is between 20 ms and 150 ms."
     ::= { etherStatsEntry 12 }
        

etherStatsCollisions OBJECT-TYPE SYNTAX Counter32 UNITS "Collisions" MAX-ACCESS read-only STATUS current DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment.

etherStatsCollisions OBJECT-TYPE SYNTAXカウンタユニットを「衝突」MAX-ACCESS read-only説明「このイーサネットセグメント上の衝突の総数の最良推定値。

         The value returned will depend on the location of the
         RMON probe. Section 8.2.1.3 (10BASE-5) and section
         10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
         station must detect a collision, in the receive mode, if
         three or more stations are transmitting simultaneously.  A
         repeater port must detect a collision when two or more stations are transmitting simultaneously.  Thus a probe
         placed on a repeater port could record more collisions
         than a probe connected to a station on the same segment
         would.
        

Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions.

10BASE-Tを考慮した場合、プローブの場所ははるかに小さい役割を果たしています。 802.3規格IEEEの14.2.1.4(10BASE-T)が(送信と同時に受信)DOとRD回路上の信号の同時存在のような衝突を定義します。それが送信している場合、10BASE-Tステーションは、衝突を検出することができます。従って局と中継器上に配置されたプローブは、同じ数の衝突を報告しなければなりません。

         Note also that an RMON probe inside a repeater should
         ideally report collisions between the repeater and one or
         more other hosts (transmit collisions as defined by IEEE
         802.3k) plus receiver collisions observed on any coax
         segments to which the repeater is connected."
     ::= { etherStatsEntry 13 }
        
 etherStatsPkts64Octets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were 64 octets in length
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 14 }
        
 etherStatsPkts65to127Octets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were between
         65 and 127 octets in length inclusive
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 15 }
        

etherStatsPkts128to255Octets OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only

etherStatsPkts128to255Octets OBJECT-TYPE構文Counter32ユニット "パケット" MAX-ACCESS読み取り専用

     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were between
         128 and 255 octets in length inclusive
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 16 }
        
 etherStatsPkts256to511Octets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were between
         256 and 511 octets in length inclusive
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 17 }
        
 etherStatsPkts512to1023Octets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were between
         512 and 1023 octets in length inclusive
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 18 }
        
 etherStatsPkts1024to1518Octets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of packets (including bad
         packets) received that were between
         1024 and 1518 octets in length inclusive
         (excluding framing bits but including FCS octets)."
     ::= { etherStatsEntry 19 }
        

etherStatsOwner OBJECT-TYPE SYNTAX OwnerString MAX-ACCESS read-create STATUS current

etherStatsOwnerのOBJECT-TYPE SYNTAX OwnerString MAX-ACCESSはリード作成しますステータス現在

     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { etherStatsEntry 20 }
        
 etherStatsStatus OBJECT-TYPE
     SYNTAX     EntryStatus
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The status of this etherStats entry."
     ::= { etherStatsEntry 21 }
        

-- The History Control Group

- 履歴制御グループ

-- Implementation of the History Control group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The history control group controls the periodic statistical -- sampling of data from various types of networks. The -- historyControlTable stores configuration entries that each -- define an interface, polling period, and other parameters. -- Once samples are taken, their data is stored in an entry -- in a media-specific table. Each such entry defines one -- sample, and is associated with the historyControlEntry that -- caused the sample to be taken. Each counter in the -- etherHistoryEntry counts the same event as its similarly-named -- counterpart in the etherStatsEntry, except that each value here -- is a cumulative sum during a sampling period. -- -- If the probe keeps track of the time of day, it should start -- the first sample of the history at a time such that -- when the next hour of the day begins, a sample is -- started at that instant. This tends to make more -- user-friendly reports, and enables comparison of reports -- from different probes that have relatively accurate time -- of day. -- -- The probe is encouraged to add two history control entries -- per monitored interface upon initialization that describe a short -- term and a long term polling period. Suggested parameters are 30 -- seconds for the short term polling period and 30 minutes for -- the long term period.

- 履歴制御グループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - ネットワークの様々な種類のデータのサンプリング - 履歴制御グループは、周期的な統計を制御します。インターフェイス、ポーリング周期、及び他のパラメータを定義する - - 各historyControlTableの格納構成エントリ。 - サンプルが採取されると、そのデータは、エントリに格納されている - メディア固有テーブルに。サンプル、そのたhistoryControlEntryに関連している - - そのような各エントリは、1つを定義するサンプルが採取される原因となりました。内の各カウンタ - サンプリング期間中の累積合計である - ここでは、それぞれの値があることを除いて、etherStatsEntryで対応 - etherHistoryEntryは、その同じ名前のと同じイベントをカウントします。 - - プローブが一日の時間を追跡する場合は、起動する必要があります - 歴史の最初のサンプルを、このようなことを一度に - 日の次の時間が始まる時、サンプルがされて - それで開始しますインスタント。これは、よりにする傾向がある - ユーザーフレンドリーなレポートを、レポートの比較を可能にします - 一日の - 比較的正確な時間を持っている異なるプローブから。 - - 監視対象インターフェイスごとに、初期化時に短い説明 - - および長期のポーリング期間をプローブは、二つの履歴制御エントリを追加することが推奨されます。短期ポーリング期間の秒と30分 - - 長期期間推奨パラメータは30です。

historyControlTable OBJECT-TYPE SYNTAX SEQUENCE OF HistoryControlEntry MAX-ACCESS not-accessible

アクセス不可能たhistoryControlEntry MAX-ACCESS OF historyControlTableのOBJECT-TYPE構文配列

     STATUS     current
     DESCRIPTION
         "A list of history control entries."
     ::= { history 1 }
        
 historyControlEntry OBJECT-TYPE
     SYNTAX     HistoryControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of parameters that set up a periodic sampling of
         statistics.  As an example, an instance of the
         historyControlInterval object might be named
         historyControlInterval.2"
     INDEX { historyControlIndex }
     ::= { historyControlTable 1 }
        
 HistoryControlEntry ::= SEQUENCE {
     historyControlIndex             Integer32,
     historyControlDataSource        OBJECT IDENTIFIER,
     historyControlBucketsRequested  Integer32,
     historyControlBucketsGranted    Integer32,
     historyControlInterval          Integer32,
     historyControlOwner             OwnerString,
     historyControlStatus            EntryStatus
 }
        
 historyControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in the
         historyControl table.  Each such entry defines a
         set of samples at a particular interval for an
         interface on the device."
     ::= { historyControlEntry 1 }
        

historyControlDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the source of the data for which historical data was collected and placed in a media-specific table on behalf of this historyControlEntry. This source can be any interface on this device. In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 2233 [17], for the desired interface. For example, if an entry were to receive data from interface #1, this object would be set to ifIndex.1.

historyControlDataSource OBJECT-TYPE構文オブジェクト識別子MAX-ACCESSはリード作成ステータス現在の説明は「このオブジェクトは履歴データを収集し、このたhistoryControlEntryの代わりにメディア特有のテーブルに置かれたため、データのソースを識別する。このソースは、いずれであってもよいですこのデバイスのインターフェイス。特定のインターフェイスを識別するために、この目的は、所望のインタフェースのために、RFC 2233 [17]で定義されたifIndexオブジェクトのインスタンスを識別しなければならない。例えば、エントリーがインタフェース#1からデータを受信した場合1は、このオブジェクトはifIndex.1に設定されるでしょう。

         The statistics in this group reflect all packets
         on the local network segment attached to the identified
         interface.
        

An agent may or may not be able to tell if fundamental changes to the media of the interface have occurred and necessitate an invalidation of this entry. For example, a hot-pluggable ethernet card could be pulled out and replaced by a token-ring card. In such a case, if the agent has such knowledge of the change, it is recommended that it invalidate this entry.

エージェントは、インタフェースのメディアに対する基本的な変更が発生した場合は教えてくれと、このエントリの無効化を必要とすることができない可能性があります。例えば、ホットプラグ対応のイーサネットカードを引き抜くことができ、トークンリングカードに置き換えます。エージェントが変更のような知識を持っている場合、このような場合には、それは、このエントリを無効にすることをお勧めします。

         This object may not be modified if the associated
         historyControlStatus object is equal to valid(1)."
     ::= { historyControlEntry 2 }
        

historyControlBucketsRequested OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The requested number of discrete time intervals over which data is to be saved in the part of the media-specific table associated with this historyControlEntry.

historyControlBucketsRequested OBJECT-TYPE構文Integer32(1 65535)MAX-ACCESSリード作成ステータス現在の説明「データがこのたhistoryControlEntryに関連付けられたメディア固有テーブルの一部で保存されるべき上の離散時間間隔の要求数。

         When this object is created or modified, the probe
         should set historyControlBucketsGranted as closely to
         this object as is possible for the particular probe
         implementation and available resources."
     DEFVAL { 50 }
     ::= { historyControlEntry 3 }
        

historyControlBucketsGranted OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of discrete sampling intervals over which data shall be saved in the part of the media-specific table associated with this historyControlEntry.

historyControlBucketsGranted OBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS read-only説明「データがこのたhistoryControlEntryに関連付けられたメディア固有テーブルの一部で保存されなければならないその上の離散サンプリング間隔の数。

         When the associated historyControlBucketsRequested
         object is created or modified, the probe
         should set this object as closely to the requested
         value as is possible for the particular
         probe implementation and available resources.  The
         probe must not lower this value except as a result
         of a modification to the associated
         historyControlBucketsRequested object.
        

There will be times when the actual number of buckets associated with this entry is less than the value of this object. In this case, at the end of each sampling interval, a new bucket will be added to the media-specific table.

このエントリに関連付けられたバケットの実際の数は、このオブジェクトの値よりも小さい倍があります。この場合、各サンプリング間隔の終わりに、新しいバケットはメディア対応表に追加されます。

When the number of buckets reaches the value of this object and a new bucket is to be added to the media-specific table, the oldest bucket associated with this historyControlEntry shall be deleted by the agent so that the new bucket can be added.

バケットの数がこのオブジェクトの値に達すると、新しいバケットがメディア特有のテーブルに追加するとき、新しいバケットが追加できるように、本たhistoryControlEntryに関連した最も古いバケットはエージェントによって削除されなければなりません。

When the value of this object changes to a value less than the current value, entries are deleted from the media-specific table associated with this historyControlEntry. Enough of the oldest of these entries shall be deleted by the agent so that their number remains less than or equal to the new value of this object.

このオブジェクトの値が現在の値よりも小さい値に変化したとき、エントリがこのたhistoryControlEntryに関連付けられたメディア固有テーブルから削除されます。その数は、このオブジェクトの新しい値以下ままであるように、これらのエントリの最古の十分はエージェントによって削除されなければなりません。

         When the value of this object changes to a value greater
         than the current value, the number of associated media-
         specific entries may be allowed to grow."
     ::= { historyControlEntry 4 }
        

historyControlInterval OBJECT-TYPE SYNTAX Integer32 (1..3600) UNITS "Seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this historyControlEntry. This interval can be set to any number of seconds between 1 and 3600 (1 hour).

historyControlIntervalのOBJECT-TYPE構文Integer32(1..3600)UNITS「秒」MAX-ACCESSリード作成ステータス現在の説明「データに関連付けられたメディア固有テーブルの一部に各バケットのためにサンプリングされた上秒間隔このたhistoryControlEntry。この間隔は1と3600(1時間)の間の秒の任意の数に設定することができます。

         Because the counters in a bucket may overflow at their maximum value with no indication, a prudent manager will
         take into account the possibility of overflow in any of
         the associated counters.  It is important to consider the
         minimum time in which any counter could overflow on a
         particular media type and set the historyControlInterval
         object to a value less than this interval.  This is
         typically most important for the 'octets' counter in any
         media-specific table.  For example, on an Ethernet
         network, the etherHistoryOctets counter could overflow
         in about one hour at the Ethernet's maximum
         utilization.
        
         This object may not be modified if the associated
         historyControlStatus object is equal to valid(1)."
     DEFVAL { 1800 }
     ::= { historyControlEntry 5 }
        
 historyControlOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { historyControlEntry 6 }
        

historyControlStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this historyControl entry.

historyControlStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESSはリード作成しますステータス現在の説明は「このhistoryControlエントリのステータスを。

         Each instance of the media-specific table associated
         with this historyControlEntry will be deleted by the agent
         if this historyControlEntry is not equal to valid(1)."
     ::= { historyControlEntry 7 }
        

-- The Ethernet History Group

- イーサネット歴史グループ

-- Implementation of the Ethernet History group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Ethernet History group records periodic statistical samples -- from a network and stores them for later retrieval. -- Once samples are taken, their data is stored in an entry -- in a media-specific table. Each such entry defines one

- イーサネット歴史グループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - ネットワークから、および後の検索のためにそれらを格納する - イーサネット履歴グループは、周期的な統計サンプルを記録します。 - サンプルが採取されると、そのデータは、エントリに格納されている - メディア固有テーブルに。このような各エントリは、1つを定義します

-- sample, and is associated with the historyControlEntry that -- caused the sample to be taken. This group defines the -- etherHistoryTable, for Ethernet networks. --

- 試料が採取される原因となった - 試料を、そしてたhistoryControlEntryに関連しています。イーサネットネットワークのために、etherHistoryTable - このグループは定義されています。 -

 etherHistoryTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF EtherHistoryEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of Ethernet history entries."
     ::= { history 2 }
        
 etherHistoryEntry OBJECT-TYPE
     SYNTAX     EtherHistoryEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "An historical sample of Ethernet statistics on a particular
         Ethernet interface.  This sample is associated with the
         historyControlEntry which set up the parameters for
         a regular collection of these samples.  As an example, an
         instance of the etherHistoryPkts object might be named
         etherHistoryPkts.2.89"
     INDEX { etherHistoryIndex , etherHistorySampleIndex }
     ::= { etherHistoryTable 1 }
        
 EtherHistoryEntry ::= SEQUENCE {
     etherHistoryIndex                 Integer32,
     etherHistorySampleIndex           Integer32,
     etherHistoryIntervalStart         TimeTicks,
     etherHistoryDropEvents            Counter32,
     etherHistoryOctets                Counter32,
     etherHistoryPkts                  Counter32,
     etherHistoryBroadcastPkts         Counter32,
     etherHistoryMulticastPkts         Counter32,
     etherHistoryCRCAlignErrors        Counter32,
     etherHistoryUndersizePkts         Counter32,
     etherHistoryOversizePkts          Counter32,
     etherHistoryFragments             Counter32,
     etherHistoryJabbers               Counter32,
     etherHistoryCollisions            Counter32,
     etherHistoryUtilization           Integer32
 }
        

etherHistoryIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only

etherHistoryIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS読み取り専用

     STATUS     current
     DESCRIPTION
         "The history of which this entry is a part.  The
         history identified by a particular value of this
         index is the same history as identified
         by the same value of historyControlIndex."
     ::= { etherHistoryEntry 1 }
        
 etherHistorySampleIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..2147483647)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies the particular
         sample this entry represents among all samples
         associated with the same historyControlEntry.
         This index starts at 1 and increases by one
         as each new sample is taken."
     ::= { etherHistoryEntry 2 }
        
 etherHistoryIntervalStart OBJECT-TYPE
     SYNTAX     TimeTicks
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of sysUpTime at the start of the interval
         over which this sample was measured.  If the probe
         keeps track of the time of day, it should start
         the first sample of the history at a time such that
         when the next hour of the day begins, a sample is
         started at that instant.  Note that following this
         rule may require the probe to delay collecting the
         first sample of the history, as each sample must be
         of the same interval.  Also note that the sample which
         is currently being collected is not accessible in this
         table until the end of its interval."
     ::= { etherHistoryEntry 3 }
        
 etherHistoryDropEvents OBJECT-TYPE
     SYNTAX     Counter32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of events in which packets
         were dropped by the probe due to lack of resources
         during this sampling interval.  Note that this number
         is not necessarily the number of packets dropped, it
         is just the number of times this condition has been detected."
     ::= { etherHistoryEntry 4 }
        
 etherHistoryOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The total number of octets of data (including
         those in bad packets) received on the
         network (excluding framing bits but including
         FCS octets)."
     ::= { etherHistoryEntry 5 }
        
 etherHistoryPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets (including bad packets)
         received during this sampling interval."
     ::= { etherHistoryEntry 6 }
        
 etherHistoryBroadcastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets received during this
         sampling interval that were directed to the
         broadcast address."
     ::= { etherHistoryEntry 7 }
        
 etherHistoryMulticastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets received during this
         sampling interval that were directed to a
         multicast address.  Note that this number does not
         include packets addressed to the broadcast address."
     ::= { etherHistoryEntry 8 }
        
 etherHistoryCRCAlignErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets received during this
         sampling interval that had a length (excluding
         framing bits but including FCS octets) between
         64 and 1518 octets, inclusive, but had either a bad Frame
         Check Sequence (FCS) with an integral number of octets
         (FCS Error) or a bad FCS with a non-integral number
         of octets (Alignment Error)."
     ::= { etherHistoryEntry 9 }
        
 etherHistoryUndersizePkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets received during this
         sampling interval that were less than 64 octets
         long (excluding framing bits but including FCS
         octets) and were otherwise well formed."
     ::= { etherHistoryEntry 10 }
        
 etherHistoryOversizePkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets received during this
         sampling interval that were longer than 1518
         octets (excluding framing bits but including
         FCS octets) but were otherwise well formed."
     ::= { etherHistoryEntry 11 }
        

etherHistoryFragments OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bits but including FCS octets) had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

etherHistoryFragmentsのOBJECT-TYPE構文Counter32 UNITSパケットの合計数は、長さが64オクテット未満(フレーミングビットを除くが、FCSオクテットを含む)は、Aのいずれかを有していたこのサンプリングインターバルの間に受信された「パケット」MAX-ACCESS read-only説明」オクテットの整数(FCSエラー)またはオクテットの非整数(アラインメントエラー)との悪いFCSとの悪いフレームチェックシーケンス(FCS)。

         Note that it is entirely normal for etherHistoryFragments to
         increment.  This is because it counts both runts (which are
         normal occurrences due to collisions) and noise hits."
     ::= { etherHistoryEntry 12 }
        

etherHistoryJabbers OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

etherHistoryJabbers OBJECT-TYPE SYNTAX Counter32ユニットパケットの数が長い1518個のオクテット(フレーミングビットを除き、FCSオクテットを含む)よりもしたこのサンプリングインターバルの間に受信した「パケット」MAX-ACCESS read-onlyステータス現在の説明」、そして持っていたいずれかの悪いですオクテットの整数(FCSエラー)またはオクテットの非整数(アラインメントエラー)との悪いFCSを持つフレームチェックシーケンス(FCS)。

         Note that this definition of jabber is different
         than the definition in IEEE-802.3 section 8.2.1.5
         (10BASE5) and section 10.3.1.4 (10BASE2).  These
         documents define jabber as the condition where any
         packet exceeds 20 ms.  The allowed range to detect
         jabber is between 20 ms and 150 ms."
     ::= { etherHistoryEntry 13 }
        

etherHistoryCollisions OBJECT-TYPE SYNTAX Counter32 UNITS "Collisions" MAX-ACCESS read-only STATUS current DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment during this sampling interval.

etherHistoryCollisions OBJECT-TYPE SYNTAXカウンタユニットを「衝突」MAX-ACCESS read-only説明「このサンプリングインターバルの間に、このイーサネットセグメント上の衝突の総数の最良推定値。

         The value returned will depend on the location of the
         RMON probe. Section 8.2.1.3 (10BASE-5) and section
         10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
         station must detect a collision, in the receive mode, if
         three or more stations are transmitting simultaneously.  A
         repeater port must detect a collision when two or more stations are transmitting simultaneously.  Thus a probe
         placed on a repeater port could record more collisions
         than a probe connected to a station on the same segment
         would.
        

Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions.

10BASE-Tを考慮した場合、プローブの場所ははるかに小さい役割を果たしています。 802.3規格IEEEの14.2.1.4(10BASE-T)が(送信と同時に受信)DOとRD回路上の信号の同時存在のような衝突を定義します。それが送信している場合、10BASE-Tステーションは、衝突を検出することができます。従って局と中継器上に配置されたプローブは、同じ数の衝突を報告しなければなりません。

         Note also that an RMON probe inside a repeater should
         ideally report collisions between the repeater and one or
         more other hosts (transmit collisions as defined by IEEE
         802.3k) plus receiver collisions observed on any coax
         segments to which the repeater is connected."
     ::= { etherHistoryEntry 14 }
        
 etherHistoryUtilization OBJECT-TYPE
     SYNTAX     Integer32 (0..10000)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The best estimate of the mean physical layer
         network utilization on this interface during this
         sampling interval, in hundredths of a percent."
     ::= { etherHistoryEntry 15 }
        

-- The Alarm Group

- アラームグループ

-- Implementation of the Alarm group is optional. The Alarm Group -- requires the implementation of the Event group. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Alarm group periodically takes statistical samples from -- variables in the probe and compares them to thresholds that have -- been configured. The alarm table stores configuration -- entries that each define a variable, polling period, and -- threshold parameters. If a sample is found to cross the -- threshold values, an event is generated. Only variables that -- resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, -- Counter32, Counter64, Gauge32, or TimeTicks) may be monitored in -- this way. --

- アラームグループの実装はオプションです。アラームグループは - イベントグループの実装を必要とします。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - アラームグループは、定期的に統計的なサンプルを取る - プローブ内の変数としているしきい値にそれらを比較する - 設定されて。アラームテーブルは設定 - 各変数を定義するエントリ、ポーリング周期、及び - 閾値パラメータ。サンプルを交差することが分かっている場合 - 閾値を、イベントが生成されます。 INTEGERのASN.1プリミティブ型(INTEGER、構文Integer32、 - Counter32の、Counter64の、Gauge32、または時間刻み)に解決 - 唯一の変数は - このような方法で監視することができます。 -

-- This function has a hysteresis mechanism to limit the generation -- of events. This mechanism generates one event as a threshold -- is crossed in the appropriate direction. No more events are -- generated for that threshold until the opposite threshold is -- crossed. -- -- In the case of a sampling a deltaValue, a probe may implement -- this mechanism with more precision if it takes a delta sample -- twice per period, each time comparing the sum of the latest two -- samples to the threshold. This allows the detection of threshold -- crossings that span the sampling boundary. Note that this does -- not require any special configuration of the threshold value. -- It is suggested that probes implement this more precise algorithm.

- イベントの - この機能は、発生を制限するヒステリシス機構を有します。この機構は、閾値として一つのイベントを生成する - 適切な方向に交差しています。交差 - これ以上のイベントがされている - 反対のしきい値がされるまで、そのしきい値のために生成されません。 - - より精度でこの機構を、それがデルタサンプルを取る場合 - - 2倍の周期ごとに、最新の両者の和を比較するたびに - に試料採取deltaValue、プローブ実装することができる場合にはしきい値。サンプリング境界をまたぐ交差点 - これは、しきい値の検出を可能にします。しきい値の特別な設定を必要としない - これがないことに注意してください。 - プローブは、このより正確なアルゴリズムを実装することが示唆されます。

 alarmTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF AlarmEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of alarm entries."
     ::= { alarm 1 }
        
 alarmEntry OBJECT-TYPE
     SYNTAX     AlarmEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of parameters that set up a periodic checking
         for alarm conditions.  For example, an instance of the
         alarmValue object might be named alarmValue.8"
     INDEX { alarmIndex }
     ::= { alarmTable 1 }
        
 AlarmEntry ::= SEQUENCE {
     alarmIndex                    Integer32,
     alarmInterval                 Integer32,
     alarmVariable                 OBJECT IDENTIFIER,
     alarmSampleType               INTEGER,
     alarmValue                    Integer32,
     alarmStartupAlarm             INTEGER,
     alarmRisingThreshold          Integer32,
     alarmFallingThreshold         Integer32,
     alarmRisingEventIndex         Integer32,
     alarmFallingEventIndex        Integer32,
     alarmOwner                    OwnerString,
     alarmStatus                   EntryStatus
 } alarmIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in the
         alarm table.  Each such entry defines a
         diagnostic sample at a particular interval
         for an object on the device."
     ::= { alarmEntry 1 }
        

alarmInterval OBJECT-TYPE SYNTAX Integer32 UNITS "Seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in the case of deltaValue sampling - the interval should be set short enough that the sampled variable is very unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval.

OBJECT-TYPE構文Integer32のUNITS「秒」alarmInterval MAX-ACCESSはリード作成しますステータス現在の説明は「データをサンプリングし、立ち上がりと立ち下がりのしきい値と比較される秒の間隔。この変数を設定するときは、介護がで取られるべきですdeltaValueサンプリングの場合 - 単一サンプリング間隔中1 - 間隔は、サンプリングされた変数以上2 ^ 31で増減するのが非常に低いであることを十分に短く設定されるべきです。

         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 2 }
        

alarmVariable OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled.

たalarmVariable OBJECT-TYPE構文オブジェクト識別子MAX-ACCESSはリード作成ステータス現在の説明「特定の変数のオブジェクト識別子をサンプリングする。INTEGER(INTEGER、Integer32の、Counter32の、Counter64ののASN.1プリミティブ型に解決のみ変数ゲージ、またはTimeTicksの)がサンプリングされてもよいです。

         Because SNMP access control is articulated entirely
         in terms of the contents of MIB views, no access
         control mechanism exists that can restrict the value of
         this object to identify only those objects that exist
         in a particular MIB view.  Because there is thus no
         acceptable means of restricting the read access that
         could be obtained through the alarm mechanism, the
         probe must only grant write access to this object in those views that have read access to all objects on
         the probe.
        

During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4).

供給変数名が選択されたMIBビューで利用できない場合、設定された動作の間、エラーBadValueを返さなければなりません。いつでも確立alarmEntryの変数名が選択されたMIBビューでもはや利用できない場合、プローブは、(4)無効なこのalarmEntryの状態を変更する必要があります。

         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 3 }
        

alarmSampleType OBJECT-TYPE SYNTAX INTEGER { absoluteValue(1), deltaValue(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), the value of the selected variable will be compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue(2), the value of the selected variable at the last sample will be subtracted from the current value, and the difference compared with the thresholds.

alarmSampleType OBJECT-TYPE SYNTAX INTEGER {absoluteValueで(1)、deltaValue(2)} MAX-ACCESSリード作成ステータス現在の説明「選択された変数をサンプリングし、しきい値と比較する値を計算する方法を。場合は、この値オブジェクトがabsoluteValueでは、(1)、選択された変数の値をサンプリング間隔の終わりにしきい値と直接比較されている。このオブジェクトの値がdeltaValue(2)である場合、最後のサンプルにおける選択された変数の値現在の値から減算し、差をしきい値と比較されるであろう。

         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 4 }
        

alarmValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period.

alarmValue OBJECT-TYPE構文Integer32 MAX-ACCESS read-only説明「最後のサンプリング期間の統計値。サンプルタイプがdeltaValueである場合、例えば、この値は開始時のサンプルとの間の差であり、そして期間の終わり。サンプルタイプがabsoluteValueである場合、この値は期間の終了時にサンプリングされた値となります。

         This is the value that is compared with the rising and
         falling thresholds.
        
         The value during the current sampling period is not
         made available until the period is completed and will
         remain available until the next period completes."
     ::= { alarmEntry 5 }
        

alarmStartupAlarm OBJECT-TYPE SYNTAX INTEGER { risingAlarm(1), fallingAlarm(2), risingOrFallingAlarm(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single rising alarm will be generated. If the first sample after this entry becomes valid is less than or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single falling alarm will be generated.

alarmStartupAlarmのOBJECT-TYPE SYNTAX INTEGER {risingAlarm(1)とfallingAlarm(2)、risingOrFallingAlarm(3)} MAX-ACCESSはリード作成ステータス現在の説明「このエントリが最初に有効に設定されているときに送信することができる。第一場合、アラームこのエントリが有効になった後、試料はrisingThreshold以上であるとalarmStartupAlarmこのエントリの後の最初のサンプルが有効になった場合(3)、その後、単一上昇アラームが生成される。以下であるrisingAlarm(1)又はrisingOrFallingAlarmに等しいです。またはfallingThresholdとalarmStartupAlarmに等しいとfallingAlarmに等しい(2)かrisingOrFallingAlarm(3)、単一下降アラームが生成されます。

         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 6 }
        

alarmRisingThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3).

現在のサンプリング値がこのしきい値以上で、場合alarmRisingThreshold OBJECT-TYPE構文Integer32 MAX-ACCESSはリード作成ステータス現在の説明「サンプリングされた統計値のしきい値を。最後のサンプリングインターバルの値がこのしきい値未満でした、単一のイベントが生成される。このエントリの後の最初のサンプルがこの閾値以上であると関連alarmStartupAlarmはrisingAlarm(1)又はrisingOrFallingAlarmに等しい有効となる場合にも、単一のイベントが生成される(3)。

         After a rising event is generated, another such event will not be generated until the sampled value
         falls below this threshold and reaches the
         alarmFallingThreshold.
        
         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 7 }
        

alarmFallingThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3).

現在のサンプリング値がこのしきい値以下であり、かつ場合alarmFallingThreshold OBJECT-TYPE構文Integer32 MAX-ACCESSはリード作成ステータス現在の説明「サンプリングされた統計値のしきい値を。最後のサンプリングインターバルの値がこのしきい値より大きかったです、単一のイベントが生成される。このエントリの後の最初のサンプルがこのしきい値以下であると関連alarmStartupAlarmはとfallingAlarmに等しい有効となる場合にも、単一のイベントが生成される(2)かrisingOrFallingAlarm(3)。

         After a falling event is generated, another such event
         will not be generated until the sampled value
         rises above this threshold and reaches the
         alarmRisingThreshold.
        
         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 8 }
        

alarmRisingEventIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index.

alarmRisingEventIndexのOBJECT-TYPE構文Integer32(0 65535)MAX-ACCESSリード作成ステータス現在の説明「上昇しきい値を超えたときに使用されるeventEntryそれのインデックス。このインデックスの特定の値によって識別されるeventEntryそれを同じれますeventIndexオブジェクトの同じ値によって識別される。イベントテーブル内に対応するエントリがない場合、何の関連が存在しない。具体的には、この値がゼロの場合、ゼロが有効なイベントインデックスでないように、関連付けられているイベントは、生成されません。

         This object may not be modified if the associated alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 9 }
        

alarmFallingEventIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The index of the eventEntry that is used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index.

alarmFallingEventIndexのOBJECT-TYPE構文Integer32(0 65535)MAX-ACCESSリード作成ステータス現在の説明「下降しきい値を超えたときに使用されるeventEntryそれのインデックス。このインデックスの特定の値によって識別されるeventEntryそれを同じれますeventIndexオブジェクトの同じ値によって識別される。イベントテーブル内に対応するエントリがない場合、何の関連が存在しない。具体的には、この値がゼロの場合、ゼロが有効なイベントインデックスでないように、関連付けられているイベントは、生成されません。

         This object may not be modified if the associated
         alarmStatus object is equal to valid(1)."
     ::= { alarmEntry 10 }
        
 alarmOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { alarmEntry 11 }
        
 alarmStatus OBJECT-TYPE
     SYNTAX     EntryStatus
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The status of this alarm entry."
     ::= { alarmEntry 12 }
        

-- The Host Group

- ホストグループ

-- Implementation of the Host group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The host group discovers new hosts on the network by -- keeping a list of source and destination MAC Addresses seen -- in good packets. For each of these addresses, the host group

- ホストグループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - 良いパケットで - 見て、送信元と宛先MACアドレスのリストを維持する - ホストグループをすることによって、ネットワーク上の新しいホストを検出します。これらのアドレスのそれぞれについて、ホストグループ

-- keeps a set of statistics. The hostControlTable controls -- which interfaces this function is performed on, and contains -- some information about the process. On behalf of each -- hostControlEntry, data is collected on an interface and placed -- in both the hostTable and the hostTimeTable. If the -- monitoring device finds itself short of resources, it may -- delete entries as needed. It is suggested that the device -- delete the least recently used entries first.

- 統計のセットを保持します。 hostControlTableは、制御 - この機能がオンに行われるインターフェイス、および含まれる - プロセスに関する情報を。それぞれの代わりに - たhostControlEntry、データは、インターフェイス上で収集され、配置 - ホストテーブルとホスト時間テーブルの両方で。監視装置リソースの自体が短い見つけ、それが可能 - - 場合は、必要に応じてエントリを削除します。最初の最低使用エントリを削除する - デバイスがあることが示唆されます。

-- The hostTable contains entries for each address discovered on -- a particular interface. Each entry contains statistical -- data about that host. This table is indexed by the -- MAC address of the host, through which a random access -- may be achieved.

- 特定のインタフェース - ホストテーブルには、上で発見された各アドレスのエントリが含まれています。そのホストに関するデータ - 各エントリは、統計が含まれています。達成することができる - ランダムアクセスがそれを通してホストのMACアドレス、 - この表はによって指標付けされます。

-- The hostTimeTable contains data in the same format as the -- hostTable, and must contain the same set of hosts, but is -- indexed using hostTimeCreationOrder rather than hostAddress. -- The hostTimeCreationOrder is an integer which reflects -- the relative order in which a particular entry was discovered -- and thus inserted into the table. As this order, and thus -- the index, is among those entries currently in the table, -- the index for a particular entry may change if an -- (earlier) entry is deleted. Thus the association between -- hostTimeCreationOrder and hostTimeEntry may be broken at -- any time.

- ホスト時間テーブルは、同じ形式のデータが含まれている - ホストテーブル、およびホストの同じセットを含まなければならないが、ある - HOSTADDRESSはなくhostTimeCreationOrder使用して索引付け。 - 従って、テーブルに挿入 - 特定のエントリが発見された相対的な順序 - hostTimeCreationOrderを反映する整数です。このため、したがってよう - インデックス、現在のテーブルにそれらのエントリの中にある - (以前の)エントリ削除された - 場合は、特定のエントリのインデックスが変化してもよいです。従って間の関連付け - いつ - hostTimeCreationOrderとhostTimeEntryはで破断することができます。

-- The hostTimeTable has two important uses. The first is the -- fast download of this potentially large table. Because the -- index of this table runs from 1 to the size of the table, -- inclusive, its values are predictable. This allows very -- efficient packing of variables into SNMP PDU's and allows -- a table transfer to have multiple packets outstanding. -- These benefits increase transfer rates tremendously.

- ホスト時間テーブルには、2つの重要な用途があります。この潜在的に大きなテーブルの高速ダウンロード - 最初です。このテーブルのインデックステーブルのサイズに1から実行、 - - ので込み、その値は予測しています。 SNMP PDUのに変数の効率的な梱包とができます - - これは非常にすることができますテーブルの転送は、優れた複数のパケットを持っています。 - これらの利点は、転送速度を飛躍的に向上させます。

-- The second use of the hostTimeTable is the efficient discovery -- by the management station of new entries added to the table. -- After the management station has downloaded the entire table, -- it knows that new entries will be added immediately after the -- end of the current table. It can thus detect new entries there -- and retrieve them easily.

- ホスト時間テーブルの第二の使用は、効率的な発見である - テーブルに追加された新しいエントリの管理ステーションによって。 - 管理ステーションの後、テーブル全体をダウンロードした - 現在のテーブルの終わり - それは新しいエントリはすぐ後に追加されることを知っています。したがって、そこに新しいエントリを検出することができます - と簡単にそれらを取得します。

-- Because the association between hostTimeCreationOrder and -- hostTimeEntry may be broken at any time, the management -- station must monitor the related hostControlLastDeleteTime -- object. When the management station thus detects a deletion, -- it must assume that any such associations have been broken, -- and invalidate any it has stored locally. This includes

- hostTimeCreationOrderとの間の関連ので - hostTimeEntryはいつでも破壊されてもよいことは、管理 - オブジェクト - ステーションは、関連hostControlLastDeleteTimeを監視しなければなりません。管理ステーションは、このように削除を検出した場合、 - それは、そのような団体が破られていることを前提としなければならない - それはローカルに保存されているすべてを無効化します。これも

-- restarting any download of the hostTimeTable that may have been -- in progress, as well as rediscovering the end of the -- hostTimeTable so that it may detect new entries. If the -- management station does not detect the broken association, -- it may continue to refer to a particular host by its -- creationOrder while unwittingly retrieving the data associated -- with another host entirely. If this happens while downloading -- the host table, the management station may fail to download -- all of the entries in the table.

それは新しいエントリを検出することができるように、ホスト時間テーブル - - あったかもしれないホスト時間テーブルの任意のダウンロード再開 - 進行中に、同様の終了を再発見。管理ステーション壊れたアソシエーションを検出しない、 - - 場合は、別のホストと全く - 無意識のうちに関連するデータを取得中creationOrder - それは、そのことによって、特定のホストを参照し続けることができます。ダウンロード中にこの問題が発生した場合 - すべてのエントリをテーブルに - ホストテーブルを、管理ステーションは、ダウンロードに失敗することがあります。

 hostControlTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF HostControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of host table control entries."
     ::= { hosts 1 }
        
 hostControlEntry OBJECT-TYPE
     SYNTAX     HostControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of parameters that set up the discovery of hosts
         on a particular interface and the collection of statistics
         about these hosts.  For example, an instance of the
         hostControlTableSize object might be named
         hostControlTableSize.1"
     INDEX { hostControlIndex }
     ::= { hostControlTable 1 }
        
 HostControlEntry ::= SEQUENCE {
        

hostControlIndex Integer32, hostControlDataSource OBJECT IDENTIFIER, hostControlTableSize Integer32, hostControlLastDeleteTime TimeTicks, hostControlOwner OwnerString, hostControlStatus EntryStatus }

HostControlインデックス構文Integer32、HostControl DataSourceオブジェクト同定FIER、ホスト制御テーブルサイズ構文Integer32、HostControl負荷削除時の時間刻み、hostControlOwner OwnerString、HostControl状況EntryStatus}

 hostControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in the hostControl table.  Each such entry defines
         a function that discovers hosts on a particular interface
         and places statistics about them in the hostTable and
         the hostTimeTable on behalf of this hostControlEntry."
     ::= { hostControlEntry 1 }
        

hostControlDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the source of the data for this instance of the host function. This source can be any interface on this device. In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 2233 [17], for the desired interface. For example, if an entry were to receive data from interface #1, this object would be set to ifIndex.1.

hostControlDataSource OBJECT-TYPE構文オブジェクト識別子MAX-ACCESSはリード作成ステータス現在の説明は「このオブジェクトはホスト機能のこのインスタンスのデータのソースを識別する。このソースは、このデバイス上の任意のインターフェースとすることができる。特定のインターフェイスを識別するためにこの目的は、所望のインタフェースのために、[17] RFC 2233で定義され、ifIndexオブジェクトのインスタンスを識別しなければならないエントリがインターフェイス#1からデータを受信した場合、例えば、このオブジェクトはifIndex.1に設定されるでしょうに。

         The statistics in this group reflect all packets
         on the local network segment attached to the identified
         interface.
        

An agent may or may not be able to tell if fundamental changes to the media of the interface have occurred and necessitate an invalidation of this entry. For example, a hot-pluggable ethernet card could be pulled out and replaced by a token-ring card. In such a case, if the agent has such knowledge of the change, it is recommended that it invalidate this entry.

エージェントは、インタフェースのメディアに対する基本的な変更が発生した場合は教えてくれと、このエントリの無効化を必要とすることができない可能性があります。例えば、ホットプラグ対応のイーサネットカードを引き抜くことができ、トークンリングカードに置き換えます。エージェントが変更のような知識を持っている場合、このような場合には、それは、このエントリを無効にすることをお勧めします。

         This object may not be modified if the associated
         hostControlStatus object is equal to valid(1)."
     ::= { hostControlEntry 2 }
        
 hostControlTableSize OBJECT-TYPE
     SYNTAX     Integer32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of hostEntries in the hostTable and the
         hostTimeTable associated with this hostControlEntry."
     ::= { hostControlEntry 3 }
        

hostControlLastDeleteTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only

hostControlLastDeleteTimeのOBJECT-TYPE SYNTAX TimeTicksのMAX-ACCESS読み取り専用

     STATUS     current
     DESCRIPTION
         "The value of sysUpTime when the last entry
         was deleted from the portion of the hostTable
         associated with this hostControlEntry.  If no
         deletions have occurred, this value shall be zero."
     ::= { hostControlEntry 4 }
        
 hostControlOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { hostControlEntry 5 }
        

hostControlStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this hostControl entry.

hostControlStatusのOBJECT-TYPE SYNTAX EntryStatus MAX-ACCESSはリード作成しますステータス現在の説明は「このhostControlエントリのステータスを。

         If this object is not equal to valid(1), all associated
         entries in the hostTable, hostTimeTable, and the
         hostTopNTable shall be deleted by the agent."
     ::= { hostControlEntry 6 }
        
 hostTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF HostEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of host entries."
     ::= { hosts 2 }
        
 hostEntry OBJECT-TYPE
     SYNTAX     HostEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A collection of statistics for a particular host that has
         been discovered on an interface of this device.  For example,
         an instance of the hostOutBroadcastPkts object might be
         named hostOutBroadcastPkts.1.6.8.0.32.27.3.176"
     INDEX { hostIndex, hostAddress }
     ::= { hostTable 1 }
        
 HostEntry ::= SEQUENCE {
     hostAddress             OCTET STRING,
     hostCreationOrder       Integer32,
     hostIndex               Integer32,
     hostInPkts              Counter32,
     hostOutPkts             Counter32,
     hostInOctets            Counter32,
     hostOutOctets           Counter32,
     hostOutErrors           Counter32,
     hostOutBroadcastPkts    Counter32,
     hostOutMulticastPkts    Counter32
 }
        
 hostAddress OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The physical address of this host."
     ::= { hostEntry 1 }
        

hostCreationOrder OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that defines the relative ordering of the creation time of hosts captured for a particular hostControlEntry. This index shall be between 1 and N, where N is the value of the associated hostControlTableSize. The ordering of the indexes is based on the order of each entry's insertion into the table, in which entries added earlier have a lower index value than entries added later.

hostCreationOrderのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS read-only説明「特定たhostControlEntryのために捕捉されたホストの作成時の相対的な順序を定義し、インデックス。このインデックスは、1とNの間でなければなりませんNは、関連hostControlTableSizeの値である。インデックスの順序は、エントリが以前に追加したテーブルへの各エントリの挿入の順序に基づいており、後で追加されたエントリよりも低い屈折率値を有します。

         It is important to note that the order for a
         particular entry may change as an (earlier) entry
         is deleted from the table.  Because this order may
         change, management stations should make use of the
         hostControlLastDeleteTime variable in the
         hostControlEntry associated with the relevant
         portion of the hostTable.  By observing
         this variable, the management station may detect
         the circumstances where a previous association
         between a value of hostCreationOrder
         and a hostEntry may no longer hold."
     ::= { hostEntry 2 }
        
 hostIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The set of collected host statistics of which
         this entry is a part.  The set of hosts
         identified by a particular value of this
         index is associated with the hostControlEntry
         as identified by the same value of hostControlIndex."
     ::= { hostEntry 3 }
        
 hostInPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted to this
         address since it was added to the hostTable."
     ::= { hostEntry 4 }
        
 hostOutPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets, including bad packets, transmitted
         by this address since it was added to the hostTable."
     ::= { hostEntry 5 }
        
 hostInOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of octets transmitted to this address since
         it was added to the hostTable (excluding framing
         bits but including FCS octets), except for those
         octets in bad packets."
     ::= { hostEntry 6 }
        

hostOutOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only

hostOutOctets OBJECT-TYPE SYNTAX Counter32ユニット "オクテット" のMAX-ACCESS read-only

     STATUS     current
     DESCRIPTION
         "The number of octets transmitted by this address since
         it was added to the hostTable (excluding framing
         bits but including FCS octets), including those
         octets in bad packets."
     ::= { hostEntry 7 }
        
 hostOutErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of bad packets transmitted by this address
         since this host was added to the hostTable."
     ::= { hostEntry 8 }
        
 hostOutBroadcastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted by this
         address that were directed to the broadcast address
         since this host was added to the hostTable."
     ::= { hostEntry 9 }
        
 hostOutMulticastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted by this
         address that were directed to a multicast address
         since this host was added to the hostTable.
         Note that this number does not include packets
         directed to the broadcast address."
     ::= { hostEntry 10 }
        

-- host Time Table

- ホストの時刻表

hostTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF HostTimeEntry MAX-ACCESS not-accessible STATUS current

HostTimeEntry MAX-ACCESSステータス電流のホスト時間テーブルOBJECT-TYPE構文配列

     DESCRIPTION
         "A list of time-ordered host table entries."
     ::= { hosts 3 }
        
 hostTimeEntry OBJECT-TYPE
     SYNTAX     HostTimeEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A collection of statistics for a particular host that has
         been discovered on an interface of this device.  This
         collection includes the relative ordering of the creation
         time of this object.  For example, an instance of the
         hostTimeOutBroadcastPkts object might be named
         hostTimeOutBroadcastPkts.1.687"
     INDEX { hostTimeIndex, hostTimeCreationOrder }
     ::= { hostTimeTable 1 }
        
 HostTimeEntry ::= SEQUENCE {
     hostTimeAddress              OCTET STRING,
     hostTimeCreationOrder        Integer32,
     hostTimeIndex                Integer32,
     hostTimeInPkts               Counter32,
     hostTimeOutPkts              Counter32,
     hostTimeInOctets             Counter32,
     hostTimeOutOctets            Counter32,
     hostTimeOutErrors            Counter32,
     hostTimeOutBroadcastPkts     Counter32,
     hostTimeOutMulticastPkts     Counter32
 }
        
 hostTimeAddress OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The physical address of this host."
     ::= { hostTimeEntry 1 }
        

hostTimeCreationOrder OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies an entry in the hostTime table among those entries associated with the same hostControlEntry. This index shall be between 1 and N, where N is the value of the associated hostControlTableSize. The ordering of the indexes is based on the order of each entry's insertion into the table, in which entries added earlier have a lower index value than entries added later. Thus the management station has the ability to learn of new entries added to this table without downloading the entire table.

hostTimeCreationOrderのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS read-only説明「一意同じたhostControlEntryに関連したエントリのうちのhostTime表のエントリを識別するインデックス。このインデックスは1とNとの間でなければなりません、Nは、関連hostControlTableSizeの値である。インデックスの順序がテーブルに各エントリの挿入の順序に基づいており、ここで、後で追加されたエントリよりも低い屈折率値を有する以前追加されたエントリ。これにより、管理ステーションが有しますテーブル全体をダウンロードせずに、この表に追加された新しいエントリの学習能力。

         It is important to note that the index for a
         particular entry may change as an (earlier) entry
         is deleted from the table.  Because this order may
         change, management stations should make use of the
         hostControlLastDeleteTime variable in the
         hostControlEntry associated with the relevant
         portion of the hostTimeTable.  By observing
         this variable, the management station may detect
         the circumstances where a download of the table
         may have missed entries, and where a previous
         association between a value of hostTimeCreationOrder
         and a hostTimeEntry may no longer hold."
     ::= { hostTimeEntry 2 }
        
 hostTimeIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The set of collected host statistics of which
         this entry is a part.  The set of hosts
         identified by a particular value of this
         index is associated with the hostControlEntry
         as identified by the same value of hostControlIndex."
     ::= { hostTimeEntry 3 }
        
 hostTimeInPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted to this
         address since it was added to the hostTimeTable."
     ::= { hostTimeEntry 4 }
        

hostTimeOutPkts OBJECT-TYPE SYNTAX Counter32 UNITS "Packets" MAX-ACCESS read-only

hostTimeOutPktsのOBJECT-TYPE SYNTAX Counter32ユニット "パケット" MAX-ACCESS読み取り専用

     STATUS     current
     DESCRIPTION
         "The number of packets, including bad packets, transmitted
         by this address since it was added to the hostTimeTable."
     ::= { hostTimeEntry 5 }
        
 hostTimeInOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of octets transmitted to this address since
         it was added to the hostTimeTable (excluding framing
         bits but including FCS octets), except for those
         octets in bad packets."
     ::= { hostTimeEntry 6 }
        
 hostTimeOutOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of octets transmitted by this address since
         it was added to the hostTimeTable (excluding framing
         bits but including FCS octets), including those
         octets in bad packets."
     ::= { hostTimeEntry 7 }
        
 hostTimeOutErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of bad packets transmitted by this address
         since this host was added to the hostTimeTable."
     ::= { hostTimeEntry 8 }
        
 hostTimeOutBroadcastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted by this
         address that were directed to the broadcast address since this host was added to the hostTimeTable."
     ::= { hostTimeEntry 9 }
        
 hostTimeOutMulticastPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of good packets transmitted by this
         address that were directed to a multicast address
         since this host was added to the hostTimeTable.
         Note that this number does not include packets directed
         to the broadcast address."
     ::= { hostTimeEntry 10 }
        

-- The Host Top "N" Group

- ホストトップ「N」グループ

-- Implementation of the Host Top N group is optional. The Host Top N -- group requires the implementation of the host group. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Host Top N group is used to prepare reports that describe -- the hosts that top a list ordered by one of their statistics. -- The available statistics are samples of one of their -- base statistics, over an interval specified by the management -- station. Thus, these statistics are rate based. The management -- station also selects how many such hosts are reported.

- ホストトップNグループの実装はオプションです。ホストトップN - グループは、ホストグループの実装を必要とします。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - 彼らの統計のいずれかによって順序付けられたリストのトップホスト - ホストトップNグループを記述する報告書を作成するために使用されます。 - 駅 - 経営者によって指定された間隔で、ベース統計 - 利用可能な統計は、彼らの一つのサンプルです。したがって、これらの統計は、レートベースです。管理 - ステーションは、多くのそのようなホストが報告されている方法を選択します。

-- The hostTopNControlTable is used to initiate the generation of -- such a report. The management station may select the parameters -- of such a report, such as which interface, which statistic, -- how many hosts, and the start and stop times of the sampling. -- When the report is prepared, entries are created in the -- hostTopNTable associated with the relevant hostTopNControlEntry. -- These entries are static for each report after it has been -- prepared.

- そのようなレポート - hostTopNControlTableは、の生成を開始するために使用されます。管理ステーションは、パラメータを選択することができる - そのようなレポートのようなどのインタフェース、統計、など - サンプリングの方法を多数のホスト、および開始時刻と終了時刻。 - 関連hostTopNControlEntryに関連付けられhostTopNTable - 報告書が準備されている場合、エントリがで作成されます。 - 準備 - これらのエントリは、それがされた後、各レポートの静的です。

 hostTopNControlTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF HostTopNControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of top N host control entries."
     ::= { hostTopN 1 }
        

hostTopNControlEntry OBJECT-TYPE

hostTopNControlEntryのOBJECT-TYPE

     SYNTAX     HostTopNControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of parameters that control the creation of a report
         of the top N hosts according to several metrics.  For
         example, an instance of the hostTopNDuration object might
         be named hostTopNDuration.3"
     INDEX { hostTopNControlIndex }
     ::= { hostTopNControlTable 1 }
        
 HostTopNControlEntry ::= SEQUENCE {
     hostTopNControlIndex    Integer32,
     hostTopNHostIndex       Integer32,
     hostTopNRateBase        INTEGER,
     hostTopNTimeRemaining   Integer32,
     hostTopNDuration        Integer32,
     hostTopNRequestedSize   Integer32,
     hostTopNGrantedSize     Integer32,
     hostTopNStartTime       TimeTicks,
     hostTopNOwner           OwnerString,
     hostTopNStatus          EntryStatus
 }
        
 hostTopNControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry
         in the hostTopNControl table.  Each such
         entry defines one top N report prepared for
         one interface."
     ::= { hostTopNControlEntry 1 }
        

hostTopNHostIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The host table for which a top N report will be prepared on behalf of this entry. The host table identified by a particular value of this index is associated with the same host table as identified by the same value of hostIndex.

hostTopNHostIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS読作成ステータス現在の説明「トップNレポートがこのエントリに代わって調製されるのホストテーブルをこの特定の値によって識別されるホストテーブルhostIndexの同じ値によって識別されるインデックスは、同じホストテーブルに関連付けられています。

         This object may not be modified if the associated
         hostTopNStatus object is equal to valid(1)."
        
     ::= { hostTopNControlEntry 2 }
        

hostTopNRateBase OBJECT-TYPE SYNTAX INTEGER { hostTopNInPkts(1), hostTopNOutPkts(2), hostTopNInOctets(3), hostTopNOutOctets(4), hostTopNOutErrors(5), hostTopNOutBroadcastPkts(6), hostTopNOutMulticastPkts(7) } MAX-ACCESS read-create STATUS current DESCRIPTION "The variable for each host that the hostTopNRate variable is based upon.

hostTopNRateBaseのOBJECT-TYPE SYNTAX INTEGER {hostTopNInPkts(1)、hostTopNOutPkts(2)、hostTopNInOctets(3)、hostTopNOutOctets(4)、hostTopNOutErrors(5)、hostTopNOutBroadcastPkts(6)、hostTopNOutMulticastPkts(7)} MAX-ACCESS読作成ステータス現在のDESCRIPTION「hostTopNRateこれ変数は基づいている各ホストの変数。

         This object may not be modified if the associated
         hostTopNStatus object is equal to valid(1)."
     ::= { hostTopNControlEntry 3 }
        

hostTopNTimeRemaining OBJECT-TYPE SYNTAX Integer32 UNITS "Seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "The number of seconds left in the report currently being collected. When this object is modified by the management station, a new collection is started, possibly aborting a currently running report. The new value is used as the requested duration of this report, which is loaded into the associated hostTopNDuration object.

hostTopNTimeRemainingのOBJECT-TYPE構文Integer32のUNITS「秒」MAX-ACCESSはリード作成しますステータス現在の説明は「現在収集されているレポートに残された秒数。このオブジェクトが管理ステーションによって修正されると、新しいコレクションが開始されたが、おそらく中止現在実行中のレポート。新しい値が関連付けられているhostTopNDurationオブジェクトにロードされるこのレポートの要求された期間として使用されています。

         When this object is set to a non-zero value, any
         associated hostTopNEntries shall be made
         inaccessible by the monitor.  While the value of this
         object is non-zero, it decrements by one per second until
         it reaches zero.  During this time, all associated
         hostTopNEntries shall remain inaccessible.  At the time
         that this object decrements to zero, the report is made
         accessible in the hostTopNTable.  Thus, the hostTopN
         table needs to be created only at the end of the collection
         interval."
     DEFVAL { 0 }
     ::= { hostTopNControlEntry 4 }
        

hostTopNDuration OBJECT-TYPE SYNTAX Integer32 UNITS "Seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that this report has collected during the last sampling interval, or if this report is currently being collected, the number of seconds that this report is being collected during this sampling interval.

hostTopNDurationのOBJECT-TYPE構文Integer32のUNITS「秒」MAX-ACCESS read-onlyステータス現在の説明は「この報告書は、最後のサンプリングインターバルの間に収集された、またはこのレポートが現在収集されている場合は秒数、秒数このこと報告書は、このサンプリングインターバルの間に収集されています。

         When the associated hostTopNTimeRemaining object is set,
         this object shall be set by the probe to the same value
         and shall not be modified until the next time
         the hostTopNTimeRemaining is set.
        
         This value shall be zero if no reports have been
         requested for this hostTopNControlEntry."
     DEFVAL { 0 }
     ::= { hostTopNControlEntry 5 }
        

hostTopNRequestedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum number of hosts requested for the top N table.

hostTopNRequestedSizeのOBJECT-TYPE構文Integer32 MAX-ACCESSリード作成ステータス現在の説明「トップNテーブルに要求ホストの最大数。

         When this object is created or modified, the probe
         should set hostTopNGrantedSize as closely to this
         object as is possible for the particular probe
         implementation and available resources."
     DEFVAL { 10 }
     ::= { hostTopNControlEntry 6 }
        

hostTopNGrantedSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of hosts in the top N table.

hostTopNGrantedSizeのOBJECT-TYPE構文Integer32 MAX-ACCESS read-only説明「トップNテーブルのホストの最大数。

         When the associated hostTopNRequestedSize object is
         created or modified, the probe should set this
         object as closely to the requested value as is possible
         for the particular implementation and available resources. The probe must not lower this value except
         as a result of a set to the associated
         hostTopNRequestedSize object.
        
         Hosts with the highest value of hostTopNRate shall be
         placed in this table in decreasing order of this rate
         until there is no more room or until there are no more
         hosts."
     ::= { hostTopNControlEntry 7 }
        
 hostTopNStartTime OBJECT-TYPE
     SYNTAX     TimeTicks
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of sysUpTime when this top N report was
         last started.  In other words, this is the time that
         the associated hostTopNTimeRemaining object was
         modified to start the requested report."
     ::= { hostTopNControlEntry 8 }
        
 hostTopNOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { hostTopNControlEntry 9 }
        

hostTopNStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this hostTopNControl entry.

hostTopNStatusのOBJECT-TYPE SYNTAX EntryStatus MAX-ACCESSはリード作成しますステータス現在の説明は「このhostTopNControlエントリのステータスを。

         If this object is not equal to valid(1), all associated
         hostTopNEntries shall be deleted by the agent."
     ::= { hostTopNControlEntry 10 }
        
 hostTopNTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF HostTopNEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of top N host entries."
     ::= { hostTopN 2 }
        
 hostTopNEntry OBJECT-TYPE
     SYNTAX     HostTopNEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of statistics for a host that is part of a top N
         report.  For example, an instance of the hostTopNRate
         object might be named hostTopNRate.3.10"
     INDEX { hostTopNReport, hostTopNIndex }
     ::= { hostTopNTable 1 }
        
 HostTopNEntry ::= SEQUENCE {
     hostTopNReport                Integer32,
     hostTopNIndex                 Integer32,
     hostTopNAddress               OCTET STRING,
     hostTopNRate                  Integer32
 }
        
 hostTopNReport OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "This object identifies the top N report of which
         this entry is a part.  The set of hosts
         identified by a particular value of this
         object is part of the same report as identified
         by the same value of the hostTopNControlIndex object."
     ::= { hostTopNEntry 1 }
        
 hostTopNIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in
         the hostTopN table among those in the same report.
         This index is between 1 and N, where N is the
         number of entries in this table.  Increasing values
         of hostTopNIndex shall be assigned to entries with
         decreasing values of hostTopNRate until index N
         is assigned to the entry with the lowest value of
         hostTopNRate or there are no more hostTopNEntries."
     ::= { hostTopNEntry 2 }
        

hostTopNAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only

hostTopNAddress OBJECT-TYPE構文オクテット文字列MAX-ACCESS読み取り専用

     STATUS     current
     DESCRIPTION
         "The physical address of this host."
     ::= { hostTopNEntry 3 }
        
 hostTopNRate OBJECT-TYPE
     SYNTAX     Integer32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The amount of change in the selected variable
         during this sampling interval.  The selected
         variable is this host's instance of the object
         selected by hostTopNRateBase."
     ::= { hostTopNEntry 4 }
        

-- The Matrix Group

- マトリックス・グループ

-- Implementation of the Matrix group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Matrix group consists of the matrixControlTable, matrixSDTable -- and the matrixDSTable. These tables store statistics for a -- particular conversation between two addresses. As the device -- detects a new conversation, including those to a non-unicast -- address, it creates a new entry in both of the matrix tables. -- It must only create new entries based on information -- received in good packets. If the monitoring device finds -- itself short of resources, it may delete entries as needed. -- It is suggested that the device delete the least recently used -- entries first.

- マトリックス・グループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - 及びますmatrixDSTable - マトリックス・グループはmatrixControlTable、matrixSDTableで構成されています。二つのアドレス間の特定の会話 - これらの表には、統計情報を格納します。デバイスとして - 非ユニキャストのものを含めて、新しい会話を検出 - アドレスは、それがマトリックステーブルの両方に新しいエントリを作成します。 - 良いパケットで受信 - それだけの情報に基づいて新しいエントリを作成する必要があります。監視装置が見つかった場合 - リソースの自体が短く、必要に応じて、それはエントリを削除することができます。 - 最初のエントリ - デバイスが最低使用を削除することが示唆されています。

 matrixControlTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF MatrixControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of information entries for the
         traffic matrix on each interface."
     ::= { matrix 1 }
        
 matrixControlEntry OBJECT-TYPE
     SYNTAX     MatrixControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "Information about a traffic matrix on a particular interface.  For example, an instance of the
         matrixControlLastDeleteTime object might be named
         matrixControlLastDeleteTime.1"
     INDEX { matrixControlIndex }
     ::= { matrixControlTable 1 }
        
 MatrixControlEntry ::= SEQUENCE {
     matrixControlIndex           Integer32,
     matrixControlDataSource      OBJECT IDENTIFIER,
     matrixControlTableSize       Integer32,
     matrixControlLastDeleteTime  TimeTicks,
     matrixControlOwner           OwnerString,
     matrixControlStatus          EntryStatus
 }
        
 matrixControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in the
         matrixControl table.  Each such entry defines
         a function that discovers conversations on a particular
         interface and places statistics about them in the
         matrixSDTable and the matrixDSTable on behalf of this
         matrixControlEntry."
     ::= { matrixControlEntry 1 }
        

matrixControlDataSource OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION "This object identifies the source of the data from which this entry creates a traffic matrix. This source can be any interface on this device. In order to identify a particular interface, this object shall identify the instance of the ifIndex object, defined in RFC 2233 [17], for the desired interface. For example, if an entry were to receive data from interface #1, this object would be set to ifIndex.1.

matrixControlDataSource OBJECT-TYPE構文オブジェクト識別子MAX-ACCESSリード作成ステータス現在の説明は「このオブジェクトはこのエントリがトラフィック・マトリックスを作成し、そこからデータのソースを識別する。このソースは、このデバイス上の任意のインターフェースとすることができる。特定を同定するためにインターフェイス、この目的は、所望のインタフェースのために、[17] RFC 2233で定義されたifIndexオブジェクトのインスタンスを識別しなければならない。エントリーがインタフェース#1からデータを受信した場合、例えば、このオブジェクトはifIndex.1に設定されるでしょうに。

         The statistics in this group reflect all packets
         on the local network segment attached to the identified
         interface.
        

An agent may or may not be able to tell if fundamental changes to the media of the interface have occurred and necessitate an invalidation of this entry. For example, a hot-pluggable ethernet card could be pulled out and replaced by a token-ring card. In such a case, if the agent has such knowledge of the change, it is recommended that it invalidate this entry.

エージェントは、インタフェースのメディアに対する基本的な変更が発生した場合は教えてくれと、このエントリの無効化を必要とすることができない可能性があります。例えば、ホットプラグ対応のイーサネットカードを引き抜くことができ、トークンリングカードに置き換えます。エージェントが変更のような知識を持っている場合、このような場合には、それは、このエントリを無効にすることをお勧めします。

         This object may not be modified if the associated
         matrixControlStatus object is equal to valid(1)."
     ::= { matrixControlEntry 2 }
        
 matrixControlTableSize OBJECT-TYPE
     SYNTAX     Integer32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of matrixSDEntries in the matrixSDTable
         for this interface.  This must also be the value of
         the number of entries in the matrixDSTable for this
         interface."
     ::= { matrixControlEntry 3 }
        
 matrixControlLastDeleteTime OBJECT-TYPE
     SYNTAX     TimeTicks
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of sysUpTime when the last entry
         was deleted from the portion of the matrixSDTable
         or matrixDSTable associated with this matrixControlEntry.
         If no deletions have occurred, this value shall be
         zero."
     ::= { matrixControlEntry 4 }
        
 matrixControlOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { matrixControlEntry 5 }
        

matrixControlStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this matrixControl entry.

マトリックスControlStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESSはリード作成しますステータス現在の説明は「このmatrixControlエントリのステータスを。

         If this object is not equal to valid(1), all associated
         entries in the matrixSDTable and the matrixDSTable
         shall be deleted by the agent."
     ::= { matrixControlEntry 6 }
        
 matrixSDTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF MatrixSDEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of traffic matrix entries indexed by
         source and destination MAC address."
     ::= { matrix 2 }
        
 matrixSDEntry OBJECT-TYPE
     SYNTAX     MatrixSDEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A collection of statistics for communications between
         two addresses on a particular interface.  For example,
         an instance of the matrixSDPkts object might be named
         matrixSDPkts.1.6.8.0.32.27.3.176.6.8.0.32.10.8.113"
     INDEX { matrixSDIndex,
             matrixSDSourceAddress, matrixSDDestAddress }
     ::= { matrixSDTable 1 }
        
 MatrixSDEntry ::= SEQUENCE {
     matrixSDSourceAddress       OCTET STRING,
     matrixSDDestAddress         OCTET STRING,
     matrixSDIndex               Integer32,
     matrixSDPkts                Counter32,
     matrixSDOctets              Counter32,
     matrixSDErrors              Counter32
 }
        
 matrixSDSourceAddress OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The source physical address."
     ::= { matrixSDEntry 1 }
        

matrixSDDestAddress OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current

matrixSDDestAddress OBJECT-TYPE構文オクテット文字列MAX-ACCESS read-onlyステータス電流

     DESCRIPTION
         "The destination physical address."
     ::= { matrixSDEntry 2 }
        
 matrixSDIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The set of collected matrix statistics of which
         this entry is a part.  The set of matrix statistics
         identified by a particular value of this index
         is associated with the same matrixControlEntry
         as identified by the same value of matrixControlIndex."
     ::= { matrixSDEntry 3 }
        
 matrixSDPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets transmitted from the source
         address to the destination address (this number includes
         bad packets)."
     ::= { matrixSDEntry 4 }
        
 matrixSDOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of octets (excluding framing bits but
         including FCS octets) contained in all packets
         transmitted from the source address to the
         destination address."
     ::= { matrixSDEntry 5 }
        
 matrixSDErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of bad packets transmitted from
         the source address to the destination address."
     ::= { matrixSDEntry 6 }
        

-- Traffic matrix tables from destination to source

- 宛先からソースへのトラフィック行列テーブル

 matrixDSTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF MatrixDSEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of traffic matrix entries indexed by
         destination and source MAC address."
     ::= { matrix 3 }
        
 matrixDSEntry OBJECT-TYPE
     SYNTAX     MatrixDSEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A collection of statistics for communications between
         two addresses on a particular interface.  For example,
         an instance of the matrixSDPkts object might be named
         matrixSDPkts.1.6.8.0.32.10.8.113.6.8.0.32.27.3.176"
     INDEX { matrixDSIndex,
             matrixDSDestAddress, matrixDSSourceAddress }
     ::= { matrixDSTable 1 }
        
 MatrixDSEntry ::= SEQUENCE {
     matrixDSSourceAddress       OCTET STRING,
     matrixDSDestAddress         OCTET STRING,
     matrixDSIndex               Integer32,
     matrixDSPkts                Counter32,
     matrixDSOctets              Counter32,
     matrixDSErrors              Counter32
 }
        
 matrixDSSourceAddress OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The source physical address."
     ::= { matrixDSEntry 1 }
        
 matrixDSDestAddress OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The destination physical address."
     ::= { matrixDSEntry 2 }
        
 matrixDSIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The set of collected matrix statistics of which
         this entry is a part.  The set of matrix statistics
         identified by a particular value of this index
         is associated with the same matrixControlEntry
         as identified by the same value of matrixControlIndex."
     ::= { matrixDSEntry 3 }
        
 matrixDSPkts OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets transmitted from the source
         address to the destination address (this number includes
         bad packets)."
     ::= { matrixDSEntry 4 }
        
 matrixDSOctets OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of octets (excluding framing bits
         but including FCS octets) contained in all packets
         transmitted from the source address to the
         destination address."
     ::= { matrixDSEntry 5 }
        
 matrixDSErrors OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of bad packets transmitted from
         the source address to the destination address."
     ::= { matrixDSEntry 6 }
        

-- The Filter Group

- フィルタグループ

-- Implementation of the Filter group is optional.

- フィルタグループの実装はオプションです。

-- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Filter group allows packets to be captured with an -- arbitrary filter expression. A logical data and -- event stream or "channel" is formed by the packets -- that match the filter expression. -- -- This filter mechanism allows the creation of an arbitrary -- logical expression with which to filter packets. Each -- filter associated with a channel is OR'ed with the others. -- Within a filter, any bits checked in the data and status are -- AND'ed with respect to other bits in the same filter. The -- NotMask also allows for checking for inequality. Finally, -- the channelAcceptType object allows for inversion of the -- whole equation. -- -- If a management station wishes to receive a trap to alert it -- that new packets have been captured and are available for -- download, it is recommended that it set up an alarm entry that -- monitors the value of the relevant channelMatches instance. -- -- The channel can be turned on or off, and can also -- generate events when packets pass through it.

- このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - 任意のフィルタ式 - フィルタ群は、パケットがで捕捉されることを可能にします。論理データ及び - フィルタ式に一致する - イベントストリームまたは「チャネル」は、パケットによって形成されています。 - - パケットをフィルタリングするための論理式 - このフィルタ機構は、任意の作成を可能にします。各 - チャネルに関連付けられたフィルタは、他と論理和されます。 - フィルタ内、データ及び状態の確認任意のビットがされる - 同じフィルタ内の他のビットに対するAND演算します。 - NotMaskも不平等をチェックすることができます。最後に、 - 全体の方程式 - channelAcceptTypeオブジェクトが反転することができます。新しいパケットをキャプチャして使用可能ですされていること - - 管理ステーションがそれを警告するトラップを受信したい場合は - - の値を監視する - ダウンロード、アラームエントリを設定することをお勧めします関連channelMatchesインスタンス。 - - チャンネルがオンまたはオフにすることができ、またすることができます - パケットが通過するときにイベントを生成します。

 filterTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF FilterEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of packet filter entries."
     ::= { filter 1 }
        
 filterEntry OBJECT-TYPE
     SYNTAX     FilterEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of parameters for a packet filter applied on a
         particular interface.  As an example, an instance of the
         filterPktData object might be named filterPktData.12"
     INDEX { filterIndex }
     ::= { filterTable 1 }
        
 FilterEntry ::= SEQUENCE {
     filterIndex                 Integer32,
     filterChannelIndex          Integer32,
     filterPktDataOffset         Integer32, filterPktData               OCTET STRING,
     filterPktDataMask           OCTET STRING,
     filterPktDataNotMask        OCTET STRING,
     filterPktStatus             Integer32,
     filterPktStatusMask         Integer32,
     filterPktStatusNotMask      Integer32,
     filterOwner                 OwnerString,
     filterStatus                EntryStatus
 }
        
 filterIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry
         in the filter table.  Each such entry defines
         one filter that is to be applied to every packet
         received on an interface."
     ::= { filterEntry 1 }
        
 filterChannelIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "This object identifies the channel of which this filter
         is a part.  The filters identified by a particular value
         of this object are associated with the same channel as
         identified by the same value of the channelIndex object."
     ::= { filterEntry 2 }
        

filterPktDataOffset OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-create STATUS current DESCRIPTION "The offset from the beginning of each packet where a match of packet data will be attempted. This offset is measured from the point in the physical layer packet after the framing bits, if any. For example, in an Ethernet frame, this point is at the beginning of the destination MAC address.

filterPktDataOffset OBJECT-TYPE構文Integer32ユニット「オクテット」MAX-ACCESSリード作成ステータス現在の説明「パケットデータの一致が試行される各パケットの先頭からのオフセット。このオフセットは、物理層パケット内の点から測定されますもしあればフレーミングビットの後に、例えば、イーサネット(登録商標)フレームで、この点は、宛先MACアドレスの先頭にあります。

         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     DEFVAL { 0 }
        
     ::= { filterEntry 3 }
        

filterPktData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The data that is to be matched with the input packet. For each packet received, this filter and the accompanying filterPktDataMask and filterPktDataNotMask will be adjusted for the offset. The only bits relevant to this match algorithm are those that have the corresponding filterPktDataMask bit equal to one. The following three rules are then applied to every packet:

filterPktDataのOBJECT-TYPE構文オクテット文字列MAX-ACCESSはリード作成ステータス現在の説明「入力パケットに一致するデータを、各パケットを受信するため、このフィルタそして伴うことフィルタPktDataMaskフィルタPktDataNotMaskオフセットのために調整されます。ザ・このマッチアルゴリズムに関連ビットのみが1に等しい対応するフィルタPktDataMaskビットを有するものであり、以下の3つのルールは、その後、すべてのパケットに適用されます。:

         (1) If the packet is too short and does not have data
             corresponding to part of the filterPktData, the packet
             will fail this data match.
        

(2) For each relevant bit from the packet with the corresponding filterPktDataNotMask bit set to zero, if the bit from the packet is not equal to the corresponding bit from the filterPktData, then the packet will fail this data match.

対応するfilterPktDataNotMask有するパケットからそれぞれ該当するビットがゼロに設定ビットについてのパケットからのビットがfilterPktDataのからの対応するビットと等しくない場合(2)、パケットはこのデータマッチを失敗します。

(3) If for every relevant bit from the packet with the corresponding filterPktDataNotMask bit set to one, the bit from the packet is equal to the corresponding bit from the filterPktData, then the packet will fail this data match.

(3)対応するfilterPktDataNotMaskが1にセットビットがパケットからのすべての関連するビットに対して、パケットからのビットがfilterPktDataのからの対応するビットに等しい場合、パケットはこのデータマッチを失敗します。

Any packets that have not failed any of the three matches above have passed this data match. In particular, a zero length filter will match any packet.

上記の3試合のいずれも失敗しなかったパケットは、このデータマッチを渡してきました。具体的には、長さゼロのフィルタは、任意のパケットに一致するであろう。

         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 4 }
        

filterPktDataMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The mask that is applied to the match process. After adjusting this mask for the offset, only those bits in the received packet that correspond to bits set in this mask are relevant for further processing by the match algorithm. The offset is applied to filterPktDataMask in the same way it is applied to the filter. For the purposes of the matching algorithm, if the associated filterPktData object is longer than this mask, this mask is conceptually extended with '1' bits until it reaches the length of the filterPktData object.

フィルタPktDataMaskのOBJECT-TYPE構文オクテット文字列MAX-ACCESSリード作成ステータス現在の説明「マッチプロセスに適用されるマスク。このマスクに設定されたビットに対応する受信したパケットのオフセット、ビットのみのために、このマスクを調整した後マッチアルゴリズムによる更なる処理のために関連している。それはフィルタに適用されるのと同じ方法でフィルタPktDataMaskに適用されるオフセット。関連filterPktDataのオブジェクトは長く、このマスクを超える場合、マッチングアルゴリズムの目的のために、このマスクは概念的ですそれはfilterPktDataのオブジェクトの長さに達するまで、「1」ビットで拡張。

         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 5 }
        

filterPktDataNotMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The inversion mask that is applied to the match process. After adjusting this mask for the offset, those relevant bits in the received packet that correspond to bits cleared in this mask must all be equal to their corresponding bits in the filterPktData object for the packet to be accepted. In addition, at least one of those relevant bits in the received packet that correspond to bits set in this mask must be different to its corresponding bit in the filterPktData object.

するfilterPktDataNotMaskのOBJECT-TYPE構文オクテット文字列MAX-ACCESSリード作成ステータス現在の説明「マッチプロセスに適用される反転マスク。このクリアビットに対応する受信したパケットのオフセット、それらの関連ビットは、このマスクを調整した後パケットが受け入れられるようにするためのマスクは、すべてのfilterPktDataのオブジェクト内の対応するビットと等しくなければならない。また、このマスクに設定されたビットに対応する受信したパケットのそれらの関連するビットの少なくとも一方が、その対応するビットに異なっている必要がありますfilterPktDataのオブジェクト。

         For the purposes of the matching algorithm, if the associated
         filterPktData object is longer than this mask, this mask is
         conceptually extended with '0' bits until it reaches the
         length of the filterPktData object.
        
         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 6 }
        

filterPktStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The status that is to be matched with the input packet. The only bits relevant to this match algorithm are those that have the corresponding filterPktStatusMask bit equal to one. The following two rules are then applied to every packet:

filterPktStatusのOBJECT-TYPE構文Integer32 MAX-ACCESS読作成ステータス現在の説明「入力パケットに一致する状態を、このマッチアルゴリズムに関連する唯一のビットが1に等しい対応filterPktStatusMaskビットを有するものである。以下2つのルールが、その後のすべてのパケットに適用されます。

         (1) For each relevant bit from the packet status with the
             corresponding filterPktStatusNotMask bit set to zero, if
             the bit from the packet status is not equal to the corresponding bit from the filterPktStatus, then the
             packet will fail this status match.
        

(2) If for every relevant bit from the packet status with the corresponding filterPktStatusNotMask bit set to one, the bit from the packet status is equal to the corresponding bit from the filterPktStatus, then the packet will fail this status match.

(2)対応filterPktStatusNotMaskが1にセットビットがパケット状態からのすべての関連するビットに対して場合、パケットステータスからのビットがfilterPktStatusのからの対応するビットに等しい、パケットはこのステータスマッチを失敗します。

Any packets that have not failed either of the two matches above have passed this status match. In particular, a zero length status filter will match any packet's status.

上記の2つのマッチのどちらかを失敗しなかったパケットは、このステータスマッチを渡してきました。具体的には、長さゼロのステータスフィルタは、任意のパケットの状態と一致します。

The value of the packet status is a sum. This sum initially takes the value zero. Then, for each error, E, that has been discovered in this packet, 2 raised to a value representing E is added to the sum. The errors and the bits that represent them are dependent on the media type of the interface that this channel is receiving packets from.

パケットステータスの値は合計です。この合計は最初に値ゼロをとります。次に、このパケットに発見された各エラー、E、のために、Eを表す値に上げ2は合計に追加されます。エラーおよびそれらを表すビットがこのチャネルからのパケットを受信して​​いるインタフェースのメディアタイプに依存しています。

The errors defined for a packet captured off of an Ethernet interface are as follows:

次のようにイーサネットインターフェイスのオフキャプチャされたパケットのために定義されたエラーは、次のとおり

             bit #    Error
                 0    Packet is longer than 1518 octets
                 1    Packet is shorter than 64 octets
                 2    Packet experienced a CRC or Alignment error
        

For example, an Ethernet fragment would have a value of 6 (2^1 + 2^2).

たとえば、イーサネットフラグメントは6(2 ^ 1 + 2 ^ 2)の値を有するであろう。

As this MIB is expanded to new media types, this object will have other media-specific errors defined.

このMIBが新しいメディアタイプに拡張されるので、このオブジェクトは、定義された他のメディア固有のエラーを持っています。

For the purposes of this status matching algorithm, if the packet status is longer than this filterPktStatus object, this object is conceptually extended with '0' bits until it reaches the size of the packet status.

パケット状態が長く、このfilterPktStatusのオブジェクトを超える場合、パケットステータスのサイズに達するまで、この状態マッチングアルゴリズムの目的のために、このオブジェクトは、概念的に「0」ビットで拡張されます。

         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 7 }
        

filterPktStatusMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current

filterPktStatusMaskのOBJECT-TYPE構文Integer32 MAX-ACCESSはリード作成しますステータス現在

     DESCRIPTION
         "The mask that is applied to the status match process.
         Only those bits in the received packet that correspond to
         bits set in this mask are relevant for further processing
         by the status match algorithm.  For the purposes
         of the matching algorithm, if the associated filterPktStatus
         object is longer than this mask, this mask is conceptually
         extended with '1' bits until it reaches the size of the
         filterPktStatus.  In addition, if a packet status is longer
         than this mask, this mask is conceptually extended with '0'
         bits until it reaches the size of the packet status.
        
         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 8 }
        

filterPktStatusNotMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The inversion mask that is applied to the status match process. Those relevant bits in the received packet status that correspond to bits cleared in this mask must all be equal to their corresponding bits in the filterPktStatus object for the packet to be accepted. In addition, at least one of those relevant bits in the received packet status that correspond to bits set in this mask must be different to its corresponding bit in the filterPktStatus object for the packet to be accepted.

filterPktStatusNotMaskのOBJECT-TYPE構文Integer32 MAX-ACCESS読作成ステータス現在の説明「ステータスマッチプロセスに適用される反転マスク。このマスクでクリアビットに対応する受信されたパケットの状態でそれらの関連するビットは、すべてのに等しくなければなりませんまた、このマスクに設定されたビットに対応する受信されたパケットの状態でそれらの関連するビットの少なくとも一つは、パケットのためのfilterPktStatusのオブジェクトの対応するビットに異なっていなければならない。受け入れられるべきパケットのためのfilterPktStatusのオブジェクトに対応するビット受け入れられる。

         For the purposes of the matching algorithm, if the associated
         filterPktStatus object or a packet status is longer than this
         mask, this mask is conceptually extended with '0' bits until
         it reaches the longer of the lengths of the filterPktStatus
         object and the packet status.
        
         This object may not be modified if the associated
         filterStatus object is equal to valid(1)."
     ::= { filterEntry 9 }
        

filterOwner OBJECT-TYPE SYNTAX OwnerString MAX-ACCESS read-create STATUS current DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it."

filterOwner OBJECT-TYPE構文OwnerString MAX-ACCESS読作成ステータス現在の説明「従ってこのエントリを設定し、それに割り当てられたリソースを使用しているエンティティ。」

     ::= { filterEntry 10 }
        
 filterStatus OBJECT-TYPE
     SYNTAX     EntryStatus
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The status of this filter entry."
     ::= { filterEntry 11 }
        
 channelTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF ChannelEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of packet channel entries."
     ::= { filter 2 }
        
 channelEntry OBJECT-TYPE
     SYNTAX     ChannelEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of parameters for a packet channel applied on a
         particular interface.  As an example, an instance of the
         channelMatches object might be named channelMatches.3"
     INDEX { channelIndex }
     ::= { channelTable 1 }
        
 ChannelEntry ::= SEQUENCE {
     channelIndex                 Integer32,
     channelIfIndex               Integer32,
     channelAcceptType            INTEGER,
     channelDataControl           INTEGER,
     channelTurnOnEventIndex      Integer32,
     channelTurnOffEventIndex     Integer32,
     channelEventIndex            Integer32,
     channelEventStatus           INTEGER,
     channelMatches               Counter32,
     channelDescription           DisplayString,
     channelOwner                 OwnerString,
     channelStatus                EntryStatus
 }
        

channelIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current

channelIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS read-onlyステータス電流

     DESCRIPTION
         "An index that uniquely identifies an entry in the channel
         table.  Each such entry defines one channel, a logical
         data and event stream.
        
         It is suggested that before creating a channel, an
         application should scan all instances of the
         filterChannelIndex object to make sure that there are no
         pre-existing filters that would be inadvertently be linked
         to the channel."
     ::= { channelEntry 1 }
        

channelIfIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object uniquely identifies the interface on this remote network monitoring device to which the associated filters are applied to allow data into this channel. The interface identified by a particular value of this object is the same interface as identified by the same value of the ifIndex object, defined in RFC 2233 [17].

channelIfIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESSはリード作成ステータス現在の説明は「このオブジェクトの値は一意に関連するフィルタがこのチャネルにデータを可能にするために適用されるこのリモートネットワーク監視装置にインターフェイスを識別このオブジェクトの特定の値によって識別されるインターフェイスは、RFC 2233 [17]で定義され、ifIndexオブジェクトの同じ値によって特定されるように同じインタフェースです。

         The filters in this group are applied to all packets on
         the local network segment attached to the identified
         interface.
        

An agent may or may not be able to tell if fundamental changes to the media of the interface have occurred and necessitate an invalidation of this entry. For example, a hot-pluggable ethernet card could be pulled out and replaced by a token-ring card. In such a case, if the agent has such knowledge of the change, it is recommended that it invalidate this entry.

エージェントは、インタフェースのメディアに対する基本的な変更が発生した場合は教えてくれと、このエントリの無効化を必要とすることができない可能性があります。例えば、ホットプラグ対応のイーサネットカードを引き抜くことができ、トークンリングカードに置き換えます。エージェントが変更のような知識を持っている場合、このような場合には、それは、このエントリを無効にすることをお勧めします。

         This object may not be modified if the associated
         channelStatus object is equal to valid(1)."
     ::= { channelEntry 2 }
        

channelAcceptType OBJECT-TYPE SYNTAX INTEGER { acceptMatched(1), acceptFailed(2) } MAX-ACCESS read-create STATUS current DESCRIPTION

channelAcceptTypeのOBJECT-TYPE SYNTAX INTEGER {acceptMatched(1)、acceptFailed(2)} MAX-ACCESSはリード作成ステータス現在の説明

         "This object controls the action of the filters
         associated with this channel.  If this object is equal
         to acceptMatched(1), packets will be accepted to this
         channel if they are accepted by both the packet data and
         packet status matches of an associated filter.  If
         this object is equal to acceptFailed(2), packets will
         be accepted to this channel only if they fail either
         the packet data match or the packet status match of
         each of the associated filters.
        

In particular, a channel with no associated filters will match no packets if set to acceptMatched(1) case and will match all packets in the acceptFailed(2) case.

具体的には、無関連するフィルタを有するチャネルがacceptMatchedに(1)のケースを設定し、acceptFailed(2)の場合にすべてのパケットに一致する場合は何パケットと一致しないであろう。

         This object may not be modified if the associated
         channelStatus object is equal to valid(1)."
     ::= { channelEntry 3 }
        
 channelDataControl OBJECT-TYPE
     SYNTAX     INTEGER {
                  on(1),
                  off(2)
                }
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "This object controls the flow of data through this channel.
         If this object is on(1), data, status and events flow
         through this channel.  If this object is off(2), data,
         status and events will not flow through this channel."
     DEFVAL { off }
     ::= { channelEntry 4 }
        

channelTurnOnEventIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the event that is configured to turn the associated channelDataControl from off to on when the event is generated. The event identified by a particular value of this object is the same event as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In fact, if no event is intended for this channel, channelTurnOnEventIndex must be set to zero, a non-existent event index.

channelTurnOnEventIndexのOBJECT-TYPE構文Integer32(0 65535)MAX-ACCESSリード作成ステータス現在の説明は「このオブジェクトの値は、イベントが発生したときにOFFからONに関連するチャネルDataControlをオンするように構成されているイベントを特定する。イベントこのオブジェクトの特定の値によって識別されるeventIndexオブジェクトの同じ値によって識別される同じイベントである。イベントテーブル内に対応するエントリがない場合、何の関連が存在しない。実際には、何もイベントがこのチャネルのために意図されていない場合、 channelTurnOnEventIndexは非存在イベントインデックスゼロに設定する必要があります。

         This object may not be modified if the associated
         channelStatus object is equal to valid(1)."
     ::= { channelEntry 5 }
        

channelTurnOffEventIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the event that is configured to turn the associated channelDataControl from on to off when the event is generated. The event identified by a particular value of this object is the same event as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In fact, if no event is intended for this channel, channelTurnOffEventIndex must be set to zero, a non-existent event index.

channelTurnOffEventIndexのOBJECT-TYPE構文Integer32(0 65535)MAX-ACCESSはリード作成ステータス現在の説明は「このオブジェクトの値は、イベントが発生したときにオンからオフに関連するチャネルDataControlをオンするように構成されたイベントを識別する。イベントこのオブジェクトの特定の値によって識別されるeventIndexオブジェクトの同じ値によって識別される同じイベントである。イベントテーブル内に対応するエントリがない場合、何の関連が存在しない。実際には、何もイベントがこのチャネルのために意図されていない場合、 channelTurnOffEventIndexは非存在イベントインデックスゼロに設定する必要があります。

         This object may not be modified if the associated
         channelStatus object is equal to valid(1)."
     ::= { channelEntry 6 }
        

channelEventIndex OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object identifies the event that is configured to be generated when the associated channelDataControl is on and a packet is matched. The event identified by a particular value of this object is the same event as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In fact, if no event is intended for this channel, channelEventIndex must be set to zero, a non-existent event index.

channelEventIndexのOBJECT-TYPE構文Integer32(0 65535)MAX-ACCESSリード作成ステータス現在の説明は「このオブジェクトの値は、関連するチャネルDataControlがオンで、パケットが一致したときに生成されるように構成されたイベントを識別する。イベントこのオブジェクトの特定の値によって識別されるeventIndexオブジェクトの同じ値によって識別される同じイベントである。イベントテーブル内に対応するエントリがない場合、何の関連が存在しない。実際には、何もイベントがこのチャネルのために意図されていない場合、 channelEventIndexは非存在イベントインデックスゼロに設定する必要があります。

         This object may not be modified if the associated
         channelStatus object is equal to valid(1)."
     ::= { channelEntry 7 }
        

channelEventStatus OBJECT-TYPE SYNTAX INTEGER { eventReady(1), eventFired(2), eventAlwaysReady(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The event status of this channel.

channelEventStatusのOBJECT-TYPE SYNTAX INTEGER {eventReady(1)、eventFired(2)、eventAlwaysReady(3)} MAX-ACCESSリード作成ステータス現在の説明「このチャンネルのイベントステータス。

         If this channel is configured to generate events
         when packets are matched, a means of controlling
         the flow of those events is often needed.  When
         this object is equal to eventReady(1), a single
         event may be generated, after which this object
         will be set by the probe to eventFired(2).  While
         in the eventFired(2) state, no events will be
         generated until the object is modified to
         eventReady(1) (or eventAlwaysReady(3)).  The
         management station can thus easily respond to a
         notification of an event by re-enabling this object.
        
         If the management station wishes to disable this
         flow control and allow events to be generated
         at will, this object may be set to
         eventAlwaysReady(3).  Disabling the flow control
         is discouraged as it can result in high network
         traffic or other performance problems."
     DEFVAL { eventReady }
     ::= { channelEntry 8 }
        
 channelMatches OBJECT-TYPE
     SYNTAX     Counter32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of times this channel has matched a packet.
         Note that this object is updated even when
         channelDataControl is set to off."
     ::= { channelEntry 9 }
        
 channelDescription OBJECT-TYPE
     SYNTAX     DisplayString (SIZE (0..127))
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "A comment describing this channel."
     ::= { channelEntry 10 }
        

channelOwner OBJECT-TYPE

channelOwnerのOBJECT-TYPE

     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { channelEntry 11 }
        
 channelStatus OBJECT-TYPE
     SYNTAX     EntryStatus
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The status of this channel entry."
     ::= { channelEntry 12 }
        

-- The Packet Capture Group

- パケットキャプチャグループ

-- Implementation of the Packet Capture group is optional. The Packet -- Capture Group requires implementation of the Filter Group. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Packet Capture group allows packets to be captured -- upon a filter match. The bufferControlTable controls -- the captured packets output from a channel that is -- associated with it. The captured packets are placed -- in entries in the captureBufferTable. These entries are -- associated with the bufferControlEntry on whose behalf they -- were stored.

- パケットキャプチャグループの実装はオプションです。パケット - キャプチャグループでは、フィルタグループの実装を必要とします。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - フィルター一致時 - パケットキャプチャグループは、パケットをキャプチャすることを可能にします。 bufferControlTableを制御する - それに関連 - ているチャネルからキャプチャされたパケットを出力します。キャプチャされたパケットが配置されている - captureBufferTableのエントリに。これらのエントリはされている - 保存した - その代理として、彼らは上のbufferControlEntryに関連付けられています。

 bufferControlTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF BufferControlEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of buffers control entries."
     ::= { capture 1 }
        

bufferControlEntry OBJECT-TYPE SYNTAX BufferControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of parameters that control the collection of a stream of packets that have matched filters. As an example, an instance of the bufferControlCaptureSliceSize object might be named bufferControlCaptureSliceSize.3"

bufferControlEntryのOBJECT-TYPE SYNTAX BufferControlEntry MAX-ACCESSステータス現在の説明は「フィルタと一致したパケットのストリームの収集を制御するパラメータのセット。一例として、bufferControlCaptureSliceSizeオブジェクトのインスタンスは、bufferControlCaptureSliceSize.3と命名されるかもしれません"

     INDEX { bufferControlIndex }
     ::= { bufferControlTable 1 }
        
 BufferControlEntry ::= SEQUENCE {
     bufferControlIndex                Integer32,
     bufferControlChannelIndex         Integer32,
     bufferControlFullStatus           INTEGER,
     bufferControlFullAction           INTEGER,
     bufferControlCaptureSliceSize     Integer32,
     bufferControlDownloadSliceSize    Integer32,
     bufferControlDownloadOffset       Integer32,
     bufferControlMaxOctetsRequested   Integer32,
     bufferControlMaxOctetsGranted     Integer32,
     bufferControlCapturedPackets      Integer32,
     bufferControlTurnOnTime           TimeTicks,
     bufferControlOwner                OwnerString,
     bufferControlStatus               EntryStatus
 }
        
 bufferControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry
         in the bufferControl table.  The value of this
         index shall never be zero.  Each such
         entry defines one set of packets that is
         captured and controlled by one or more filters."
     ::= { bufferControlEntry 1 }
        

bufferControlChannelIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "An index that identifies the channel that is the source of packets for this bufferControl table. The channel identified by a particular value of this index is the same as identified by the same value of the channelIndex object.

bufferControlChannelIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS読作成ステータス現在の説明「このbufferControlテーブルのパケットの送信元であるチャネルを識別するインデックスである。このインデックスの特定の値によって識別されるチャネルでありますchannelIndexオブジェクトの同じ値によって識別されると同じ。

         This object may not be modified if the associated
         bufferControlStatus object is equal to valid(1)."
     ::= { bufferControlEntry 2 }
        

bufferControlFullStatus OBJECT-TYPE SYNTAX INTEGER {

ますbufferControlFullStatusのOBJECT-TYPE SYNTAX INTEGER {

                  spaceAvailable(1),
                  full(2)
                }
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "This object shows whether the buffer has room to
         accept new packets or if it is full.
        
         If the status is spaceAvailable(1), the buffer is
         accepting new packets normally.  If the status is
         full(2) and the associated bufferControlFullAction
         object is wrapWhenFull, the buffer is accepting new
         packets by deleting enough of the oldest packets
         to make room for new ones as they arrive.  Otherwise,
         if the status is full(2) and the
         bufferControlFullAction object is lockWhenFull,
         then the buffer has stopped collecting packets.
        
         When this object is set to full(2) the probe must
         not later set it to spaceAvailable(1) except in the
         case of a significant gain in resources such as
         an increase of bufferControlOctetsGranted.  In
         particular, the wrap-mode action of deleting old
         packets to make room for newly arrived packets
         must not affect the value of this object."
     ::= { bufferControlEntry 3 }
        
 bufferControlFullAction OBJECT-TYPE
     SYNTAX     INTEGER {
                  lockWhenFull(1),
                  wrapWhenFull(2)    -- FIFO
                }
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "Controls the action of the buffer when it
         reaches the full status.  When in the lockWhenFull(1)
         state and a packet is added to the buffer that
         fills the buffer, the bufferControlFullStatus will
         be set to full(2) and this buffer will stop capturing
         packets."
     ::= { bufferControlEntry 4 }
        

bufferControlCaptureSliceSize OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-create

bufferControlCaptureSliceSizeのOBJECT-TYPE構文Integer32のUNITS "オクテット" MAX-ACCESSはリード作成

     STATUS     current
     DESCRIPTION
         "The maximum number of octets of each packet
         that will be saved in this capture buffer.
         For example, if a 1500 octet packet is received by
         the probe and this object is set to 500, then only
         500 octets of the packet will be stored in the
         associated capture buffer.  If this variable is set
         to 0, the capture buffer will save as many octets
         as is possible.
        
         This object may not be modified if the associated
         bufferControlStatus object is equal to valid(1)."
     DEFVAL { 100 }
     ::= { bufferControlEntry 5 }
        

bufferControlDownloadSliceSize OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum number of octets of each packet in this capture buffer that will be returned in an SNMP retrieval of that packet. For example, if 500 octets of a packet have been stored in the associated capture buffer, the associated bufferControlDownloadOffset is 0, and this object is set to 100, then the captureBufferPacket object that contains the packet will contain only the first 100 octets of the packet.

bufferControlDownloadSliceSize OBJECT-TYPE構文Integer32ユニット「オクテット」MAX-ACCESSリード作成ステータス現在の説明「そのパケットのSNMP検索で返されるこのキャプチャバッファの各パケットのオクテットの最大数、例えば、500オクテットであればパケットの関連するキャプチャバッファに格納されている、関連bufferControlDownloadOffsetは0であり、このオブジェクトは100に設定され、そのパケットが含まcaptureBufferPacketオブジェクトは、パケットの最初の100個のオクテットを含むであろう。

         A prudent manager will take into account possible
         interoperability or fragmentation problems that may
         occur if the download slice size is set too large.
         In particular, conformant SNMP implementations are not
         required to accept messages whose length exceeds 484
         octets, although they are encouraged to support larger
         datagrams whenever feasible."
     DEFVAL { 100 }
     ::= { bufferControlEntry 6 }
        

bufferControlDownloadOffset OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-create STATUS current DESCRIPTION

bufferControlDownloadOffsetのOBJECT-TYPE構文Integer32のUNITS "オクテット" MAX-ACCESSはリード作成しますステータス現在の説明

         "The offset of the first octet of each packet
         in this capture buffer that will be returned in
         an SNMP retrieval of that packet.  For example,
         if 500 octets of a packet have been stored in the
         associated capture buffer and this object is set to
         100, then the captureBufferPacket object that
         contains the packet will contain bytes starting
         100 octets into the packet."
     DEFVAL { 0 }
     ::= { bufferControlEntry 7 }
        

bufferControlMaxOctetsRequested OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-create STATUS current DESCRIPTION "The requested maximum number of octets to be saved in this captureBuffer, including any implementation-specific overhead. If this variable is set to -1, the capture buffer will save as many octets as is possible.

、OBJECT-TYPE構文Integer32ユニット「オクテット」bufferControlMaxOctetsRequested MAX-ACCESSはリード作成ステータス現在の説明「任意の実装固有のオーバーヘッドを含むこのcaptureBufferに保存されるべきオクテットの要求された最大数を、この変数が-1に設定されている場合可能であるとしてキャプチャバッファは、多くのオクテットを保存します。

         When this object is created or modified, the probe
         should set bufferControlMaxOctetsGranted as closely
         to this object as is possible for the particular probe
         implementation and available resources.  However, if
         the object has the special value of -1, the probe
         must set bufferControlMaxOctetsGranted to -1."
     DEFVAL { -1 }
     ::= { bufferControlEntry 8 }
        

bufferControlMaxOctetsGranted OBJECT-TYPE SYNTAX Integer32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of octets that can be saved in this captureBuffer, including overhead. If this variable is -1, the capture buffer will save as many octets as possible.

bufferControlMaxOctetsGranted OBJECT-TYPE構文Integer32のUNITS「オクテット」MAX-ACCESS read-onlyステータス現在の説明「オーバーヘッドを含む、このcaptureBufferに保存することができます。この変数が-1の場合オクテットの最大数、キャプチャバッファは、できるだけ多くを保存しますできるだけオクテット。

         When the bufferControlMaxOctetsRequested object is
         created or modified, the probe should set this object
         as closely to the requested value as is possible for the
         particular probe implementation and available resources.
         However, if the request object has the special value of -1, the probe must set this object to -1.
        

The probe must not lower this value except as a result of a modification to the associated bufferControlMaxOctetsRequested object.

プローブは、関連bufferControlMaxOctetsRequestedオブジェクトへの変更の結果としてを除くこの値を下げてはなりません。

When this maximum number of octets is reached and a new packet is to be added to this capture buffer and the corresponding bufferControlFullAction is set to wrapWhenFull(2), enough of the oldest packets associated with this capture buffer shall be deleted by the agent so that the new packet can be added. If the corresponding bufferControlFullAction is set to lockWhenFull(1), the new packet shall be discarded. In either case, the probe must set bufferControlFullStatus to full(2).

オクテットのこの最大数に達し、新たなパケットがこのキャプチャバッファに追加されると、対応たbufferControlFullActionがそのようにエージェントによって削除されなければならないこのキャプチャバッファに関連付けられている最も古いパケットの十分wrapWhenFull(2)に設定されている場合新しいパケットを追加することができます。対応するたbufferControlFullActionがlockWhenFull(1)に設定されている場合は、新しいパケットが破棄されなければなりません。いずれの場合においても、プローブは、(2)完全に設定する必要がありますbufferControlFullStatus。

When the value of this object changes to a value less than the current value, entries are deleted from the captureBufferTable associated with this bufferControlEntry. Enough of the oldest of these captureBufferEntries shall be deleted by the agent so that the number of octets used remains less than or equal to the new value of this object.

現在の値よりも小さい値にこのオブジェクトの値が変更は、エントリがこのbufferControlEntry関連付けられcaptureBufferTableから削除されたとき。使用されるオクテットの数がこのオブジェクトの新しい値以下のままであるように、これらのキャプチャBufferEntriesの最古の十分はエージェントによって削除されなければなりません。

         When the value of this object changes to a value greater
         than the current value, the number of associated
         captureBufferEntries may be allowed to grow."
     ::= { bufferControlEntry 9 }
        
 bufferControlCapturedPackets OBJECT-TYPE
     SYNTAX     Integer32
     UNITS      "Packets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of packets currently in this captureBuffer."
     ::= { bufferControlEntry 10 }
        

bufferControlTurnOnTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when this capture buffer was first turned on."

bufferControlTurnOnTime OBJECT-TYPE構文TimeTicksのMAX-ACCESS read-only説明「このキャプチャバッファが最初にオンになったときにsysUpTimeの値。」

     ::= { bufferControlEntry 11 }
        
 bufferControlOwner OBJECT-TYPE
     SYNTAX     OwnerString
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The entity that configured this entry and is therefore
         using the resources assigned to it."
     ::= { bufferControlEntry 12 }
        
 bufferControlStatus OBJECT-TYPE
     SYNTAX     EntryStatus
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The status of this buffer Control Entry."
     ::= { bufferControlEntry 13 }
        
 captureBufferTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF CaptureBufferEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of packets captured off of a channel."
     ::= { capture 2 }
        
 captureBufferEntry OBJECT-TYPE
     SYNTAX     CaptureBufferEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A packet captured off of an attached network.  As an
         example, an instance of the captureBufferPacketData
         object might be named captureBufferPacketData.3.1783"
     INDEX { captureBufferControlIndex, captureBufferIndex }
     ::= { captureBufferTable 1 }
        
 CaptureBufferEntry ::= SEQUENCE {
     captureBufferControlIndex   Integer32,
     captureBufferIndex          Integer32,
     captureBufferPacketID       Integer32,
     captureBufferPacketData     OCTET STRING,
     captureBufferPacketLength   Integer32,
     captureBufferPacketTime     Integer32,
     captureBufferPacketStatus   Integer32
 } captureBufferControlIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The index of the bufferControlEntry with which
         this packet is associated."
     ::= { captureBufferEntry 1 }
        

captureBufferIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies an entry in the captureBuffer table associated with a particular bufferControlEntry. This index will start at 1 and increase by one for each new packet added with the same captureBufferControlIndex.

captureBufferIndexのOBJECT-TYPE構文Integer32(1 2147483647)MAX-ACCESS read-only説明「一意に特定bufferControlEntryに関連付けcaptureBuffer表のエントリを識別するインデックスは、このインデックスは1から始まり、一つの増加のためであろうそれぞれの新しいパケットが同じと追加されるcaptureBufferControlIndex。

         Should this value reach 2147483647, the next packet
         added with the same captureBufferControlIndex shall
         cause this value to wrap around to 1."
     ::= { captureBufferEntry 2 }
        
 captureBufferPacketID OBJECT-TYPE
     SYNTAX     Integer32
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that describes the order of packets
         that are received on a particular interface.
         The packetID of a packet captured on an
         interface is defined to be greater than the
         packetID's of all packets captured previously on
         the same interface.  As the captureBufferPacketID
         object has a maximum positive value of 2^31 - 1,
         any captureBufferPacketID object shall have the
         value of the associated packet's packetID mod 2^31."
     ::= { captureBufferEntry 3 }
        
 captureBufferPacketData OBJECT-TYPE
     SYNTAX     OCTET STRING
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The data inside the packet, starting at the beginning
         of the packet plus any offset specified in the associated bufferControlDownloadOffset, including any
         link level headers.  The length of the data in this object
         is the minimum of the length of the captured packet minus
         the offset, the length of the associated
         bufferControlCaptureSliceSize minus the offset, and the
         associated bufferControlDownloadSliceSize.  If this minimum
         is less than zero, this object shall have a length of zero."
     ::= { captureBufferEntry 4 }
        
 captureBufferPacketLength OBJECT-TYPE
     SYNTAX     Integer32
     UNITS      "Octets"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The actual length (off the wire) of the packet stored
         in this entry, including FCS octets."
     ::= { captureBufferEntry 5 }
        
 captureBufferPacketTime OBJECT-TYPE
     SYNTAX     Integer32
     UNITS      "Milliseconds"
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The number of milliseconds that had passed since
         this capture buffer was first turned on when this
         packet was captured."
     ::= { captureBufferEntry 6 }
        

captureBufferPacketStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A value which indicates the error status of this packet.

captureBufferPacketStatusのOBJECT-TYPE構文Integer32 MAX-ACCESS read-only説明「このパケットのエラーステータスを示す値。

         The value of this object is defined in the same way as
         filterPktStatus.  The value is a sum.  This sum
         initially takes the value zero.  Then, for each
         error, E, that has been discovered in this packet,
         2 raised to a value representing E is added to the sum.
        

The errors defined for a packet captured off of an Ethernet interface are as follows:

次のようにイーサネットインターフェイスのオフキャプチャされたパケットのために定義されたエラーは、次のとおり

             bit #    Error
                 0    Packet is longer than 1518 octets
        
                 1    Packet is shorter than 64 octets
                 2    Packet experienced a CRC or Alignment error
                 3    First packet in this capture buffer after
                      it was detected that some packets were
                      not processed correctly.
                 4    Packet's order in buffer is only approximate
                      (May only be set for packets sent from
                      the probe)
        

For example, an Ethernet fragment would have a value of 6 (2^1 + 2^2).

たとえば、イーサネットフラグメントは6(2 ^ 1 + 2 ^ 2)の値を有するであろう。

         As this MIB is expanded to new media types, this object
         will have other media-specific errors defined."
     ::= { captureBufferEntry 7 }
        

-- The Event Group

- イベントグループ

-- Implementation of the Event group is optional. -- Consult the MODULE-COMPLIANCE macro for the authoritative -- conformance information for this MIB. -- -- The Event group controls the generation and notification -- of events from this device. Each entry in the eventTable -- describes the parameters of the event that can be triggered. -- Each event entry is fired by an associated condition located -- elsewhere in the MIB. An event entry may also be associated -- with a function elsewhere in the MIB that will be executed -- when the event is generated. For example, a channel may -- be turned on or off by the firing of an event. -- -- Each eventEntry may optionally specify that a log entry -- be created on its behalf whenever the event occurs. -- Each entry may also specify that notification should -- occur by way of SNMP trap messages. In this case, the -- community for the trap message is given in the associated -- eventCommunity object. The enterprise and specific trap -- fields of the trap are determined by the condition that -- triggered the event. Two traps are defined: risingAlarm and -- fallingAlarm. If the eventTable is triggered by a condition -- specified elsewhere, the enterprise and specific trap fields -- must be specified for traps generated for that condition.

- イベントグループの実装はオプションです。 - このMIBのための適合性情報 - 権威のためのMODULE-COMPLIANCEマクロを参照してください。 - - このデバイスからのイベント - イベントグループは、生成と通知を制御します。イベントテーブルの各エントリは - トリガできるイベントのパラメータについて説明します。 - 他の場所にMIBに - 各イベントエントリは、位置関連条件によって焼成します。イベントが発生したとき - 他の場所で実行されるMIBの機能を - イベントエントリはまた、関連していてもよいです。例えば、チャネルがよい - イベントの発生によってオンまたはオフにすること。 - - イベントが発生するたびに、その代わりに作成する - 各eventEntryそれは、必要に応じてログエントリがあることを指定してもよいです。 - また、その通知を指定することができ、各エントリには、必要がある - SNMPトラップメッセージを経由して起こります。この場合、 - eventCommunityオブジェクト - トラップメッセージのコミュニティは、関連で与えられます。企業と特定のトラップ - イベントをトリガ - トラップのフィールドは、その条件によって決定されます。 risingAlarmと - とfallingAlarm:二つのトラップが定義されています。イベントテーブルは、条件によってトリガされた場合 - 他の場所で指定された、企業や特定のトラップフィールドは - その状態のために生成されるトラップのために指定する必要があります。

eventTable OBJECT-TYPE SYNTAX SEQUENCE OF EventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

eventEntryそれMAX-ACCESSステータス現在の説明のイベントテーブルOBJECT-TYPE構文配列

         "A list of events to be generated."
     ::= { event 1 }
        
 eventEntry OBJECT-TYPE
     SYNTAX     EventEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of parameters that describe an event to be generated
         when certain conditions are met.  As an example, an instance
         of the eventLastTimeSent object might be named
         eventLastTimeSent.6"
     INDEX { eventIndex }
     ::= { eventTable 1 }
        
 EventEntry ::= SEQUENCE {
     eventIndex          Integer32,
     eventDescription    DisplayString,
     eventType           INTEGER,
     eventCommunity      OCTET STRING,
     eventLastTimeSent   TimeTicks,
     eventOwner          OwnerString,
     eventStatus         EntryStatus
 }
        
 eventIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..65535)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry in the
         event table.  Each such entry defines one event that
         is to be generated when the appropriate conditions
         occur."
     ::= { eventEntry 1 }
        
 eventDescription OBJECT-TYPE
     SYNTAX     DisplayString (SIZE (0..127))
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "A comment describing this event entry."
     ::= { eventEntry 2 }
        
 eventType OBJECT-TYPE
     SYNTAX     INTEGER {
                  none(1),
                  log(2), snmptrap(3),    -- send an SNMP trap
                  logandtrap(4)
                }
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "The type of notification that the probe will make
         about this event.  In the case of log, an entry is
         made in the log table for each event.  In the case of
         snmp-trap, an SNMP trap is sent to one or more
         management stations."
     ::= { eventEntry 3 }
        
 eventCommunity OBJECT-TYPE
     SYNTAX     OCTET STRING (SIZE (0..127))
     MAX-ACCESS read-create
     STATUS     current
     DESCRIPTION
         "If an SNMP trap is to be sent, it will be sent to
         the SNMP community specified by this octet string."
     ::= { eventEntry 4 }
        
 eventLastTimeSent OBJECT-TYPE
     SYNTAX     TimeTicks
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of sysUpTime at the time this event
         entry last generated an event.  If this entry has
         not generated any events, this value will be
         zero."
     ::= { eventEntry 5 }
        

eventOwner OBJECT-TYPE SYNTAX OwnerString MAX-ACCESS read-create STATUS current DESCRIPTION "The entity that configured this entry and is therefore using the resources assigned to it.

eventOwnerのOBJECT-TYPE SYNTAX OwnerString MAX-ACCESSはリード作成しますステータス現在の説明「従ってこのエントリを設定し、それに割り当てられたリソースを使用している実体を。

         If this object contains a string starting with 'monitor'
         and has associated entries in the log table, all connected
         management stations should retrieve those log entries,
         as they may have significance to all management stations
         connected to this device"
     ::= { eventEntry 6 }
        

eventStatus OBJECT-TYPE SYNTAX EntryStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this event entry.

eventStatusのOBJECT-TYPE SYNTAX EntryStatus MAX-ACCESSはリード作成しますステータス現在の説明は「このイベントエントリのステータスを。

         If this object is not equal to valid(1), all associated
         log entries shall be deleted by the agent."
     ::= { eventEntry 7 }
        
 --
 logTable OBJECT-TYPE
     SYNTAX     SEQUENCE OF LogEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A list of events that have been logged."
     ::= { event 2 }
        
 logEntry OBJECT-TYPE
     SYNTAX     LogEntry
     MAX-ACCESS not-accessible
     STATUS     current
     DESCRIPTION
         "A set of data describing an event that has been
         logged.  For example, an instance of the logDescription
         object might be named logDescription.6.47"
     INDEX { logEventIndex, logIndex }
     ::= { logTable 1 }
        
 LogEntry ::= SEQUENCE {
     logEventIndex           Integer32,
     logIndex                Integer32,
     logTime                 TimeTicks,
     logDescription          DisplayString
 }
        

logEventIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The event entry that generated this log entry. The log identified by a particular value of this index is associated with the same eventEntry as identified by the same value of eventIndex."

logEventIndexのOBJECT-TYPE構文Integer32(1 65535)MAX-ACCESS read-only説明「このログエントリを生成したイベントエントリによって識別される。このインデックスの特定の値によって識別されるログは同じeventEntryそれに関連付けられていますれるeventIndexの同じ値。」

     ::= { logEntry 1 }
        
 logIndex OBJECT-TYPE
     SYNTAX     Integer32 (1..2147483647)
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An index that uniquely identifies an entry
         in the log table amongst those generated by the
         same eventEntries.  These indexes are
         assigned beginning with 1 and increase by one
         with each new log entry.  The association
         between values of logIndex and logEntries
         is fixed for the lifetime of each logEntry.
         The agent may choose to delete the oldest
         instances of logEntry as required because of
         lack of memory.  It is an implementation-specific
         matter as to when this deletion may occur."
     ::= { logEntry 2 }
        
 logTime OBJECT-TYPE
     SYNTAX     TimeTicks
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "The value of sysUpTime when this log entry was created."
     ::= { logEntry 3 }
        
 logDescription OBJECT-TYPE
     SYNTAX     DisplayString (SIZE (0..255))
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION
         "An implementation dependent description of the
         event that activated this log entry."
     ::= { logEntry 4 }
        

-- Remote Network Monitoring Traps

- リモートネットワーク監視トラップ

 rmonEventsV2 OBJECT-IDENTITY
     STATUS      current
     DESCRIPTION "Definition point for RMON notifications."
     ::= { rmon 0 }
        

risingAlarm NOTIFICATION-TYPE OBJECTS { alarmIndex, alarmVariable, alarmSampleType, alarmValue, alarmRisingThreshold } STATUS current

risingAlarm NOTIFICATION-TYPEオブジェクト{alarmIndex、たalarmVariable、a​​larmSampleType、alarmValue、alarmRisingThreshold} STATUS電流

     DESCRIPTION
         "The SNMP trap that is generated when an alarm
         entry crosses its rising threshold and generates
         an event that is configured for sending SNMP
         traps."
     ::= { rmonEventsV2 1 }
        
 fallingAlarm NOTIFICATION-TYPE
     OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
               alarmValue, alarmFallingThreshold }
     STATUS    current
     DESCRIPTION
         "The SNMP trap that is generated when an alarm
         entry crosses its falling threshold and generates
         an event that is configured for sending SNMP
         traps."
     ::= { rmonEventsV2 2 }
        

-- Conformance information

- 適合情報

 rmonCompliances OBJECT IDENTIFIER ::= { rmonConformance 9 }
 rmonGroups      OBJECT IDENTIFIER ::= { rmonConformance 10 }
        

-- Compliance Statements rmonCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The requirements for conformance to the RMON MIB. At least one of the groups in this module must be implemented to conform to the RMON MIB. Implementations of this MIB must also implement the system group of MIB-II [16] and the IF-MIB [17]." MODULE -- this module

- コンプライアンスステートメントrmonCompliance MODULE-COMPLIANCEステータス現在の説明「RMON MIBに適合するための要件このモジュールの基の少なくとも一つは、RMON MIBに適合するように実装する必要があり、このMIBの実装は、システムのグループを実装しなければなりません。 [16] MIB-IIおよびIF-MIB [17]の。」 MODULE - このモジュール

       GROUP rmonEtherStatsGroup
           DESCRIPTION
               "The RMON Ethernet Statistics Group is optional."
        

GROUP rmonHistoryControlGroup DESCRIPTION "The RMON History Control Group is optional."

GROUP rmonHistoryControlGroupの説明は「RMON履歴制御グループはオプションです。」

GROUP rmonEthernetHistoryGroup DESCRIPTION "The RMON Ethernet History Group is optional."

GROUP rmonEthernetHistoryGroupのDESCRIPTION "RMONイーサネットヒストリグループはオプションです。"

GROUP rmonAlarmGroup DESCRIPTION

GROUP rmonAlarmGroup説明

"The RMON Alarm Group is optional."

「RMONアラームグループはオプションです。」

GROUP rmonHostGroup DESCRIPTION "The RMON Host Group is mandatory when the rmonHostTopNGroup is implemented."

GROUP rmonHostGroupのDESCRIPTION「rmonHostTopNGroupが実装されたときにRMONホストグループが必須です。」

GROUP rmonHostTopNGroup DESCRIPTION "The RMON Host Top N Group is optional."

GROUP rmonHostTopNGroupのDESCRIPTION "RMONホスト上Nグループはオプションです。"

GROUP rmonMatrixGroup DESCRIPTION "The RMON Matrix Group is optional."

GROUP rmonMatrixGroupのDESCRIPTION "RMONマトリックス・グループはオプションです。"

GROUP rmonFilterGroup DESCRIPTION "The RMON Filter Group is mandatory when the rmonPacketCaptureGroup is implemented."

GROUP rmonFilterGroupのDESCRIPTION「rmonPacketCaptureGroupが実装されたときにRMONフィルタグループが必須です。」

GROUP rmonPacketCaptureGroup DESCRIPTION "The RMON Packet Capture Group is optional."

GROUP rmonPacketCaptureGroupの説明は「RMONパケットキャプチャグループはオプションです。」

       GROUP rmonEventGroup
           DESCRIPTION
               "The RMON Event Group is mandatory when the
               rmonAlarmGroup is implemented."
     ::= { rmonCompliances 1 }
        

rmonEtherStatsGroup OBJECT-GROUP OBJECTS { etherStatsIndex, etherStatsDataSource, etherStatsDropEvents, etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, etherStatsMulticastPkts, etherStatsCRCAlignErrors, etherStatsUndersizePkts, etherStatsOversizePkts, etherStatsFragments, etherStatsJabbers, etherStatsCollisions, etherStatsPkts64Octets, etherStatsPkts65to127Octets, etherStatsPkts128to255Octets, etherStatsPkts256to511Octets, etherStatsPkts512to1023Octets, etherStatsPkts1024to1518Octets, etherStatsOwner, etherStatsStatus } STATUS current DESCRIPTION "The RMON Ethernet Statistics Group."

rmonEtherStatsGroupオブジェクト・グループオブジェクト{etherStatsIndex、etherStatsDataSource、etherStatsDropEvents、etherStatsOctets、でetherStatsPkts、etherStatsBroadcastPkts、etherStatsMulticastPkts、etherStatsCRCAlignErrors、etherStatsUndersizePkts、etherStatsOversizePkts、etherStatsFragments、etherStatsJabbers、etherStatsCollisions、etherStatsPkts64Octets、etherStatsPkts65to127Octets、etherStatsPkts128to255Octets、etherStatsPkts256to511Octets、etherStatsPkts512to1023Octets、etherStatsPkts1024to1518Octets、etherStatsOwner、のetherStatsStatus} STATUS電流DESCRIPTION「RMONイーサネット統計グループ。」

         ::= { rmonGroups 1 }
        
     rmonHistoryControlGroup OBJECT-GROUP
         OBJECTS {
             historyControlIndex, historyControlDataSource,
             historyControlBucketsRequested,
             historyControlBucketsGranted, historyControlInterval,
             historyControlOwner, historyControlStatus
         }
         STATUS current
         DESCRIPTION
             "The RMON History Control Group."
         ::= { rmonGroups 2 }
        
     rmonEthernetHistoryGroup OBJECT-GROUP
         OBJECTS {
             etherHistoryIndex, etherHistorySampleIndex,
             etherHistoryIntervalStart, etherHistoryDropEvents,
             etherHistoryOctets, etherHistoryPkts,
             etherHistoryBroadcastPkts, etherHistoryMulticastPkts,
             etherHistoryCRCAlignErrors, etherHistoryUndersizePkts,
             etherHistoryOversizePkts, etherHistoryFragments,
             etherHistoryJabbers, etherHistoryCollisions,
             etherHistoryUtilization
         }
         STATUS current
         DESCRIPTION
             "The RMON Ethernet History Group."
         ::= { rmonGroups 3 }
        
     rmonAlarmGroup OBJECT-GROUP
         OBJECTS {
             alarmIndex, alarmInterval, alarmVariable,
             alarmSampleType, alarmValue, alarmStartupAlarm,
             alarmRisingThreshold, alarmFallingThreshold,
             alarmRisingEventIndex, alarmFallingEventIndex,
             alarmOwner, alarmStatus
         }
         STATUS current
         DESCRIPTION
             "The RMON Alarm Group."
         ::= { rmonGroups 4 }
        
     rmonHostGroup OBJECT-GROUP
         OBJECTS {
             hostControlIndex, hostControlDataSource,
             hostControlTableSize, hostControlLastDeleteTime,
             hostControlOwner, hostControlStatus, hostAddress, hostCreationOrder, hostIndex,
             hostInPkts, hostOutPkts, hostInOctets,
             hostOutOctets, hostOutErrors, hostOutBroadcastPkts,
             hostOutMulticastPkts, hostTimeAddress,
             hostTimeCreationOrder, hostTimeIndex,
             hostTimeInPkts, hostTimeOutPkts, hostTimeInOctets,
             hostTimeOutOctets, hostTimeOutErrors,
             hostTimeOutBroadcastPkts, hostTimeOutMulticastPkts
         }
         STATUS current
         DESCRIPTION
             "The RMON Host Group."
         ::= { rmonGroups 5 }
        
     rmonHostTopNGroup OBJECT-GROUP
         OBJECTS {
             hostTopNControlIndex, hostTopNHostIndex,
             hostTopNRateBase, hostTopNTimeRemaining,
             hostTopNDuration, hostTopNRequestedSize,
             hostTopNGrantedSize, hostTopNStartTime,
             hostTopNOwner, hostTopNStatus,
             hostTopNReport, hostTopNIndex,
             hostTopNAddress, hostTopNRate
         }
         STATUS current
         DESCRIPTION
             "The RMON Host Top 'N' Group."
         ::= { rmonGroups 6 }
        
     rmonMatrixGroup OBJECT-GROUP
         OBJECTS {
             matrixControlIndex, matrixControlDataSource,
             matrixControlTableSize, matrixControlLastDeleteTime,
             matrixControlOwner, matrixControlStatus,
             matrixSDSourceAddress, matrixSDDestAddress,
             matrixSDIndex, matrixSDPkts,
             matrixSDOctets, matrixSDErrors,
             matrixDSSourceAddress, matrixDSDestAddress,
             matrixDSIndex, matrixDSPkts,
             matrixDSOctets, matrixDSErrors
         }
         STATUS current
         DESCRIPTION
             "The RMON Matrix Group."
         ::= { rmonGroups 7 }
        

rmonFilterGroup OBJECT-GROUP OBJECTS {

rmonFilterGroupオブジェクト・グループオブジェクト{

             filterIndex, filterChannelIndex, filterPktDataOffset,
             filterPktData, filterPktDataMask,
             filterPktDataNotMask, filterPktStatus,
             filterPktStatusMask, filterPktStatusNotMask,
             filterOwner, filterStatus,
             channelIndex, channelIfIndex, channelAcceptType,
             channelDataControl, channelTurnOnEventIndex,
             channelTurnOffEventIndex, channelEventIndex,
             channelEventStatus, channelMatches,
             channelDescription, channelOwner, channelStatus
         }
         STATUS current
         DESCRIPTION
             "The RMON Filter Group."
         ::= { rmonGroups 8 }
        
     rmonPacketCaptureGroup OBJECT-GROUP
         OBJECTS {
             bufferControlIndex, bufferControlChannelIndex,
             bufferControlFullStatus, bufferControlFullAction,
             bufferControlCaptureSliceSize,
             bufferControlDownloadSliceSize,
             bufferControlDownloadOffset,
             bufferControlMaxOctetsRequested,
             bufferControlMaxOctetsGranted,
             bufferControlCapturedPackets,
             bufferControlTurnOnTime,
             bufferControlOwner, bufferControlStatus,
             captureBufferControlIndex, captureBufferIndex,
             captureBufferPacketID, captureBufferPacketData,
             captureBufferPacketLength, captureBufferPacketTime,
             captureBufferPacketStatus
         }
         STATUS current
         DESCRIPTION
             "The RMON Packet Capture Group."
         ::= { rmonGroups 9 }
        

rmonEventGroup OBJECT-GROUP OBJECTS { eventIndex, eventDescription, eventType, eventCommunity, eventLastTimeSent, eventOwner, eventStatus, logEventIndex, logIndex, logTime, logDescription } STATUS current DESCRIPTION

rmonEventGroupオブジェクト・グループオブジェクト{eventIndexと、eventDescription、eventTypeを、eventCommunity、eventLastTimeSent、eventOwner、eventStatus、logEventIndex、logIndex、LOGTIME、logDescription} STATUSの現在の記述

             "The RMON Event Group."
         ::= { rmonGroups 10 }
        
     rmonNotificationGroup NOTIFICATION-GROUP
         NOTIFICATIONS { risingAlarm, fallingAlarm }
         STATUS        current
         DESCRIPTION
             "The RMON Notification Group."
         ::= { rmonGroups 11 }
 END
        
6. Security Considerations
6.セキュリティの考慮事項

In order to implement this MIB, a probe must capture all packets on the locally-attached network, including packets between third parties. These packets are analyzed to collect network addresses, protocol usage information, and conversation statistics. Data of this nature may be considered sensitive in some environments. In such environments the administrator may wish to restrict SNMP access to the probe.

このMIBを実装するために、プローブは、第三者との間のパケットを含む、ローカルに接続されたネットワーク上のすべてのパケットをキャプチャしなければなりません。これらのパケットは、ネットワークアドレス、プロトコルの使用情報、および会話の統計情報を収集するために分析されます。この種のデータは、いくつかの環境に敏感であると考えてよいです。このような環境では、管理者は、プローブへのSNMPアクセスを制限することを望むかもしれません。

This MIB also includes functions for returning the contents of captured packets, potentially including sensitive user data or passwords. It is recommended that SNMP access to these functions be restricted.

このMIBはまた、潜在的に敏感なユーザデータやパスワードを含む、キャプチャされたパケットの内容を戻すための機能を含みます。これらの関数へのSNMPアクセスを制限することをお勧めします。

There are a number of management objects defined in this MIB that have a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations.

読み書きおよび/またはリード作成のMAX-ACCESS節を持っているこのMIBで定義された管理オブジェクトの数があります。そのようなオブジェクトは、いくつかのネットワーク環境に敏感又は脆弱と考えることができます。適切な保護のない非安全な環境におけるSET操作のサポートはネットワーク操作のときにマイナスの影響を与える可能性があります。

SNMPv1 by itself is not a secure environment. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB.

それ自体でSNMPv1が安全な環境ではありません。ネットワーク自体が(IPSecを使用することにより、例えば)安全であっても、その後も、安全なネットワーク上で/ SETにアクセスし、GETだれに許容されているかのように何の制御(読み取り/変更/作成/削除)この内のオブジェクトが存在しませんMIB。

It is recommended that the implementors consider the security features as provided by the SNMPv3 framework. Specifically, the use of the User-based Security Model RFC 2574 [12] and the View-based Access Control Model RFC 2575 [15] is recommended.

SNMPv3フレームワークで提供するように実装者がセキュリティ機能を検討することをお勧めします。具体的には、ユーザベースセキュリティモデルのRFC 2574 [12]とビューベースアクセス制御モデルRFC 2575 [15]の使用が推奨されます。

It is then a customer/user responsibility to ensure that the SNMP entity giving access to an instance of this MIB, is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them.

このMIBのインスタンスへのアクセスを与えるSNMP実体が、適切にのみプリンシパル(ユーザ)にオブジェクトへのアクセスを提供するように設定されていることを確認するために、顧客/ユーザーの責任実際にGETまたはSET(変化への正当な権利を有することです/)/削除、それらを作成します。

7. Acknowledgments
7.謝辞

This document was produced by the IETF Remote Network Monitoring Working Group.

このドキュメントはIETFのリモートネットワーク監視ワーキンググループによって作成されました。

8. Author's Address
8.著者のアドレス

Steve Waldbusser

スティーブWaldbusser

Phone: +1-650-948-6500 Fax: +1-650-745-0671 Email: waldbusser@nextbeacon.com

電話:+ 1-650-948-6500ファックス:+ 1-650-745-0671 Eメール:waldbusser@nextbeacon.com

9. References
9.参考文献

[1] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing SNMP Management Frameworks", RFC 2571, April 1999.

[1]ハリントン、D.、Presuhn、R.、およびB. Wijnenの、RFC 2571、1999年4月 "SNMP管理フレームワークを記述するためのアーキテクチャ"。

[2] Rose, M. and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based Internets", STD 16, RFC 1155, May 1990.

[2]ローズ、M.、およびK. McCloghrie、 "構造とTCP / IPベースのインターネットのための経営情報の識別"、STD 16、RFC 1155、1990年5月を。

[3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16, RFC 1212, March 1991.

[3]ローズ、M.、およびK. McCloghrie、 "簡潔なMIB定義"、STD 16、RFC 1212、1991年3月。

[4] Rose, M., "A Convention for Defining Traps for use with the SNMP", RFC 1215, March 1991.

[4]ローズ、M.、 "SNMPとの使用のためのDefining Trapsのための条約"、RFC 1215、1991年3月。

[5] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

[5] McCloghrie、K.、パーキンス、D.、Schoenwaelder、J.、ケース、J.、ローズ、M.およびS. Waldbusser、 "経営情報バージョン2(SMIv2)の構造"、STD 58、RFC 2578、 1999年4月。

[6] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999.

[6] McCloghrie、K.、パーキンス、D.、Schoenwaelder、J.、ケース、J.、ローズ、M.およびS. Waldbusser、 "SMIv2のためのテキストの表記法"、STD 58、RFC 2579、1999年4月。

[7] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J., Rose, M. and S. Waldbusser, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999.

[7] McCloghrie、K.、パーキンス、D.、Schoenwaelder、J.、ケース、J.、ローズ、M.およびS. Waldbusser、STD 58、RFC 2580、1999年4月 "SMIv2のための順応文"。

[8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple Network Management Protocol", STD 15, RFC 1157, May 1990.

[8]ケース、J.、ヒョードル、M.、Schoffstall、M.、およびJ.デーヴィン、 "簡単なネットワーク管理プロトコル"、STD 15、RFC 1157、1990年5月。

[9] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Introduction to Community-based SNMPv2", RFC 1901, January 1996.

[9]ケース、J.、McCloghrie、K.、ローズ、M.およびS. Waldbusser、 "コミュニティベースのSNMPv2の概要"、RFC 1901、1996年1月。

[10] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1906, January 1996.

[10]ケース、J.、McCloghrie、K.、ローズ、M.、およびS. Waldbusser、RFC 1906 "簡易ネットワーク管理プロトコル(SNMPv2)のバージョン2のための交通マッピング"、1996年1月。

[11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)", RFC 2572, April 1999.

[11]ケース、J.、ハリントンD.、Presuhn R.とB. Wijnenの、 "メッセージ処理と簡単なネットワーク管理プロトコル(SNMP)のための派遣"、RFC 2572、1999年4月。

[12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)", RFC 2574, April 1999.

[12]ブルーメンソール、U.とB. Wijnenの、 "ユーザベースセキュリティモデル(USM)簡易ネットワーク管理プロトコル(SNMPv3の)のバージョン3のために"、RFC 2574、1999年4月。

[13] Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2)", RFC 1905, January 1996.

[13]ケース、J.、McCloghrie、K.、ローズ、M.およびS. Waldbusser、 "簡単なネットワーク管理プロトコルのバージョン2のためのプロトコル操作(SNMPv2の)"、RFC 1905、1996年1月。

[14] Levi, D., Meyer, P. and B. Stewart, "SNMPv3 Applications", RFC 2573, April 1999.

[14]レビ、D.、マイヤー、P.およびB.スチュワート、 "SNMPv3のアプリケーション"、RFC 2573、1999年4月。

[15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)", RFC 2575, April 1999.

[15] Wijnenの、B.、Presuhn、R.とK. McCloghrie、 "簡易ネットワーク管理プロトコルのためのビューベースアクセス制御モデル(VACM)(SNMP)"、RFC 2575、1999年4月。

[16] McCloghrie, K. and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets: MIB-II", STD 17, RFC 1213, March 1991.

[16] McCloghrie、K.とM.ローズ、エディターズ、 "TCP / IPベースのインターネットのネットワーク管理のための管理情報ベース:MIB-II"、STD 17、RFC 1213、1991年3月。

[17] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB using SMIv2", RFC 2233, November 1997.

[17] McCloghrie、K.およびF. Kastenholzと、 "SMIv2のを使用してインターフェイスグループMIB"、RFC 2233、1997年11月。

[18] Waldbusser, S., "Remote Network Monitoring MIB", RFC 1757, February 1995.

[18] Waldbusser、S.、 "リモートネットワーク監視MIB"、RFC 1757、1995年2月。

[19] Waldbusser, S., "Token Ring Extensions to the Remote Network Monitoring MIB", RFC 1513, September 1993.

[19] Waldbusser、S.、 "リモートネットワーク監視MIBへのトークンリング拡張機能"、RFC 1513、1993年9月。

[20] Waldbusser, S., "Remote Network Monitoring Management Information Base Version 2 using SMIv2", RFC 2021, January 1997.

[20] Waldbusser、S.、 "SMIv2のを使用してリモートネットワーク監視管理情報ベースバージョン2"、RFC 2021、1997年1月。

[21] Waterman, R., Lahaye, B., Romascanu, D. and S. Waldbusser, "Remote Network Monitoring MIB Extensions for Switched Networks Version 1.0", RFC 2613, June 1999.

[21]ウォーターマン、R.、Lahaye、B.、Romascanu、D.とS. Waldbusser、 "リモートネットワーク監視スイッチングネットワークバージョン1.0のMIB拡張機能"、RFC 2613、1999年6月。

[22] Case, J., Mundy, R., Partain, D. and B. Stewart, "Introduction to Version 3 of the Internet-standard Network Management Framework", RFC 2570, April 1999.

[22]ケース、J.、マンディ、R.、パーテイン、D.とB.スチュワート、 "インターネット標準ネットワーク管理フレームワークのバージョン3への序論"、RFC 2570、1999年4月。

10. Intellectual Property
10.知的財産

The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat.

IETFは、そのような権限下で、ライセンスがたりないかもしれない可能性があるためにどの本書または程度に記載されている技術の実装や使用に関係すると主張される可能性があります任意の知的財産やその他の権利の有効性または範囲に関していかなる位置を取りません利用可能。また、そうした権利を特定するために取り組んできたことを表していないん。スタンダードトラックおよび標準関連文書における権利に関するIETFの手続きの情報は、BCP-11に記載されています。権利の主張のコピーは、出版のために利用可能とライセンスの保証が利用できるようにする、または本仕様の実装者または利用者が、そのような所有権の使用のための一般的なライセンスまたは許可を取得するために作られた試みの結果を得ることができますIETF事務局から。

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director.

IETFは、その注意にこの標準を実践するために必要な場合があり技術をカバーすることができる任意の著作権、特許または特許出願、またはその他の所有権を持ってすべての利害関係者を招待します。 IETF専務に情​​報を扱ってください。

11. Full Copyright Statement
11.完全な著作権声明

Copyright (C) The Internet Society (2000). All Rights Reserved.

著作権(C)インターネット協会(2000)。全著作権所有。

This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.

この文書とその翻訳は、コピーして他の人に提供し、それ以外についてはコメントまたは派生物は、いかなる種類の制限もなく、全体的にまたは部分的に、準備コピーし、公表して配布することができることを説明したり、その実装を支援することができます、上記の著作権表示とこの段落は、すべてのそのようなコピーや派生物に含まれていることを条件とします。しかし、この文書自体は著作権のための手順はで定義されている場合には、インターネット標準を開発するために必要なものを除き、インターネットソサエティもしくは他のインターネット関連団体に著作権情報や参照を取り除くなど、どのような方法で変更されないかもしれませんインターネット標準化プロセスが続く、または英語以外の言語に翻訳するために、必要に応じなければなりません。

The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns.

上記の制限は永久で、インターネット学会やその後継者や譲渡者によって取り消されることはありません。

This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

この文書とここに含まれている情報は、基礎とインターネットソサエティおよびインターネットエンジニアリングタスクフォースはすべての保証を否認し、明示または黙示、その情報の利用がない任意の保証を含むがこれらに限定されない「として、」上に設けられています特定の目的への権利または商品性または適合性の黙示の保証を侵害します。

Acknowledgement

謝辞

Funding for the RFC Editor function is currently provided by the Internet Society.

RFC Editor機能のための基金は現在、インターネット協会によって提供されます。