Network Working Group                                         G. Beacham
Request for Comments: 5098                                Motorola, Inc.
Category: Standards Track                                       S. Kumar
                                                       Texas Instruments
                                                        S. Channabasappa
                                                               CableLabs
                                                           February 2008
        
              Signaling MIB for PacketCable and IPCablecom
                  Multimedia Terminal Adapters (MTAs)
        

Status of This Memo

このメモのステータス

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

この文書は、インターネットコミュニティのためのインターネット標準トラックプロトコルを指定し、改善のための議論と提案を要求します。このプロトコルの標準化状態と状態への「インターネット公式プロトコル標準」(STD 1)の最新版を参照してください。このメモの配布は無制限です。

Abstract

抽象

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it defines a basic set of managed objects for Simple Network Management Protocol (SNMP)-based management of PacketCable-and IPCablecom-compliant Multimedia Terminal Adapter devices.

このメモは、インターネットコミュニティでのネットワーク管理プロトコルで使用するための管理情報ベース(MIB)の一部を定義します。特に、それは簡易ネットワーク管理プロトコル(SNMP)のPacketCable-とIPCablecom準拠のマルチメディア端末アダプタデバイスのベース管理のための管理オブジェクトの基本セットを定義します。

Table of Contents

目次

   1. The Internet-Standard Management Framework ......................2
   2. Introduction ....................................................2
   3. Terminology .....................................................3
      3.1. MTA ........................................................3
      3.2. Endpoint ...................................................3
      3.3. L Line Package .............................................4
      3.4. E Line Package .............................................4
   4. Overview ........................................................4
      4.1. Structure of the MIB .......................................5
      4.2. pktcSigMibObjects ..........................................5
      4.3. pktcSigConformance .........................................6
   5. Definitions .....................................................6
   6. Examples .......................................................69
   7. Acknowledgments ................................................72
   8. Security Considerations ........................................73
   9. IANA Considerations ............................................75
   10. References ....................................................75
      10.1. Normative References .....................................75
      10.2. Informative References ...................................76
        
1. The Internet-Standard Management Framework
1.インターネット標準管理フレームワーク

For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 [RFC3410].

現在のインターネット標準の管理フレームワークを記述したドキュメントの詳細な概要については、RFC 3410 [RFC3410]のセクション7を参照してください。

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580 [RFC2580].

管理対象オブジェクトが仮想情報店を介してアクセスされ、管理情報ベースまたはMIBと呼ばれます。 MIBオブジェクトは、一般的に簡易ネットワーク管理プロトコル(SNMP)を介してアクセスされます。 MIBのオブジェクトは、管理情報(SMI)の構造で定義されたメカニズムを使用して定義されています。このメモは、STD 58、RFC 2578 [RFC2578]、STD 58、RFC 2579 [RFC2579]とSTD 58、RFC 2580 [RFC2580]に記載されているSMIv2のに準拠しているMIBモジュールを指定します。

2. Introduction
2.はじめに

A multimedia terminal adapter (MTA) is used to deliver broadband Internet, data, and/or voice access jointly with telephony service to a subscriber's or customer's premises using a cable network infrastructure. An MTA is normally installed at the customer's or subscriber's premises, and it is coupled to a multiple system operator (MSO) using a hybrid fiber coax (HFC) access network.

マルチメディア端末アダプタ(MTA)は、ケーブルネットワークインフラストラクチャを使用して加入者や顧客宅内への電話サービスと共同でブロードバンドインターネット、データ、および/または音声アクセスを提供するために使用されます。 MTAは、通常、顧客又は加入者宅内に設置され、それは、ハイブリッドファイバ同軸(HFC)アクセスネットワークを使用して、複数のシステムオペレータ(MSO)に結合されています。

An MTA is provisioned by the MSO for broadband Internet, data, and/or voice service. For more information on MTA provisioning, refer to the PacketCable Provisioning Specification [PKT-SP-PROV] and [RFC4682]. MTA devices include one or more endpoints (e.g., telephone ports), which receive call signaling information to establish ring cadence, and codecs used for providing telephony service. For more information on call signaling, refer to the PacketCable Signaling Specification [PKT-SP-MGCP] and [RFC3435]. For more information on codecs refer to the PacketCable Audio/Video Codecs Specification [PKT-SP-CODEC].

MTAは、ブロードバンドインターネット、データ、および/または音声サービスのためのMSOでプロビジョニングされます。 MTAプロビジョニングの詳細については、PacketCableのプロビジョニング仕様[PKT-SP-PROV]及び[RFC4682]を参照。 MTAデバイスは、電話サービスを提供するために使用される1つ以上の呼び出し音を確立するための呼シグナリング情報を受信するエンドポイント(例えば、電話ポート)、及びコーデックを含みます。呼シグナリングの詳細については、PacketCableのシグナリング仕様[PKT-SP-MGCP]及び[RFC3435]を参照。コーデックの詳細についてはPacketCableのオーディオ/ビデオコーデック仕様[PKT-SP-CODEC]を参照してください。

Telephone systems are typically very complex and often have a wide distribution. It is therefore important for management systems to support MTAs from multiple vendors at the same time, including those from multiple countries. This MIB module provides objects suitable for managing signaling for MTA devices in the widest possible range of markets.

電話システムは、典型的には、非常に複雑であり、しばしば広い分布を持っています。管理システムは、複数の国からのものも含め、同時に複数のベンダーからのMTAをサポートすることがが重要です。このMIBモジュールは、市場での可能な限り広い範囲のMTAデバイスのためのシグナリングを管理するための適切なオブジェクトを提供します。

3. Terminology
3.用語

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119 [RFC2119].

この文書のキーワード "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", および "OPTIONAL" はRFC 2119 [RFC2119]に記載されているように解釈されます。

The terms "MIB module" and "information module" are used interchangeably in this memo. As used here, both terms refer to any of the three types of information modules defined in Section 3 of RFC 2578 [RFC2578].

用語「MIBモジュール」と「情報モジュールは、」このメモで交換可能に使用されます。ここで使用されるように、両方の用語は、RFC 2578 [RFC2578]のセクション3で定義された情報モジュール3種類のいずれかを指します。

3.1. MTA
Pが0.1。とき

An MTA is a PacketCable or IPCablecom compliant device providing telephony services over a cable or hybrid system used to deliver video signals to a community. It contains an interface to endpoints, a network interface, codecs, and all signaling and encapsulation functions required for Voice-over IP transport, call signaling, and Quality of Service signaling. An MTA can be an embedded or standalone device. An Embedded MTA (E-MTA) is an MTA device containing an embedded Data Over Cable Service Interface Specifications (DOCSIS) Cable Modem. A Standalone MTA (S-MTA) is an MTA device separated from the DOCSIS Cable Modem by non-DOCSIS Media Access Control (MAC) interface (e.g., Ethernet, USB).

MTAは、コミュニティに映像信号を提供するために使用するケーブルやハイブリッドシステムを介して電話サービスを提供するPacketCableのかIPCablecom準拠のデバイスです。これは、エンドポイントへのインタフェース、IPボイスオーバー輸送、コールシグナリング、およびサービスシグナリングの品質のために必要なネットワーク・インタフェース、コーデック、およびすべてのシグナリングおよびカプセル化機能が含まれています。 MTAは、埋め込みまたはスタンドアロンデバイスとすることができます。組み込みMTA(E-MTA)埋め込まれたデータオーバーケーブルサービスインターフェイス仕様(DOCSIS)ケーブルモデムを含むMTAデバイスです。スタンドアロンMTA(S-MTA)は、非DOCSISメディアアクセス制御(MAC)インターフェース(例えば、イーサネット、USB)によってDOCSISケーブルモデムから分離MTA装置です。

3.2. Endpoint
3.2. 終点

An endpoint or MTA endpoint is a standard telephony physical port located on the MTA and used for attaching the telephone device to the MTA.

エンドポイントまたはMTAのエンドポイントは、MTAに位置し、MTAに電話装置を取り付けるために使用される標準の電話の物理ポートです。

3.3. L Line Package
3.3. Lラインパッケージ

The L line package refers to the Media Gateway Control Protocol (MGCP) package for the core signaling functionality, as defined by PacketCable and IPCablecom. An MTA provides all L package elements: however, the operator determines their application.

PacketCableおよびIPCablecomによって定義されるL線パッケージは、コアシグナリング機能のためのメディアゲートウェイ制御プロトコル(MGCP)パッケージを指します。 MTAは、すべてのLパッケージ要素が用意されています。ただし、オペレータは自分のアプリケーションを決定します。

3.4. E Line Package
3.4. Eラインパッケージ

The E line package refers to the MGCP package extensions, over and above the core L package, defined in support of international requirements. E line package elements are optional, vary from country to country, and are set by operator or regulatory requirements.

E線パッケージは、上及び国際要件をサポートするために定義されたコアLパッケージ上に、MGCPパッケージの拡張を指します。 Eラインパッケージ要素は、オプションである国によって異なり、オペレータまたは規制要件によって設定されています。

4. Overview
4.概要

This MIB module provides a set of objects required for Multimedia Terminal Adapter (MTA) devices compliant with the PacketCable and IPCablecom signaling specifications published by CableLabs, the European Telecommunications Standards Institute (ETSI), and the International Telecommunication Union Telecommunication Standardization Sector (ITU-T) IPCablecom compliant Multimedia Terminal Adapter (MTA) devices. The Signaling MIB module (PKTC-IETF-SIG-MIB) is intended to update various Signaling MIB modules from which it is partly derived:

このMIBモジュールは、マルチメディアターミナルアダプタ(MTA)のPacketCable準拠のデバイスに必要なオブジェクトのセットを提供し、IPCablecom CableLabsので公表されている仕様を、シグナリング、欧州電気通信標準化機構(ETSI)、および国際電気通信連合電気通信標準化部門(ITU-T )IPCablecom準拠したマルチメディア端末アダプタ(MTA)のデバイス。シグナリングMIBモジュール(PKTC-IETF-SIG-MIB)は、それが部分的に由来する様々なシグナリングMIBモジュールをアップデートすることを意図しています。

- the PacketCable 1.0 Signaling MIB Specification [PKT-SP-MIB-SIG-1.0],

- PacketCableの1.0シグナリングMIB仕様[PKT-SP-MIB-SIG-1.0]

- the PacketCable 1.5 Signaling MIB Specification [PKT-SP-MIB-SIG-1.5],

- のPacketCable 1.5シグナリングMIB仕様[PKT-SP-MIB-SIG-1.5]

- the ITU-T IPCablecom Signaling MIB requirements [ITU-T-J169],

- ITU-T IPCablecomシグナリングMIB要件[ITU-T-J169]

- the ETSI Signaling MIB [ETSI-TS-101-909-9]. The ETSI Signaling MIB requirements also refer to various signal characteristics defined in [ETSI-TS-101-909-4], [ETSI-EN-300-001], [ETSI-EN-300-659-1], [ETSI-EN-300-324-1] and [ETSI-TR-101-183].

- ETSIシグナリングMIB [ETSI-TS-101-909-9]。 ETSIシグナリングMIB要件も[ETSI-TS-101-909-4]、[ETSI-EN-300から001]、[ETSI-EN-300-659-1]、[ETSI-で定義された様々な信号特性を参照しますEN-300-324-1]と[ETSI-TR-101から183]。

Several normative and informative references are used to help define Signaling MIB objects. As a convention, wherever PacketCable and IPCablecom requirements are equivalent, the PacketCable reference is used in the object REFERENCE clause. IPCablecom compliant MTA devices MUST use the equivalent IPCablecom references.

いくつかの規範的で有益な参照は、シグナリングMIBオブジェクトを定義するために使用されます。 PacketCableおよびIPCablecom要件は同等である限り慣例として、PacketCableの参照は、オブジェクト参照句で使用されています。 IPCablecom対応のMTAデバイスは、同等のIPCablecom参照を使用しなければなりません。

This MIB module describes the various Signaling MIB objects that are directly related to the PacketCable MTA and the endpoints supported on the MTA, each of which provides services independently. The recognition and distinction of the endpoints are made by utilizing the ifTable (IF-MIB [RFC2863]), where each index (ifIndex) value refers to a unique endpoint. This MIB module also utilizes the syntax definition of the Differentiated Services Code Point (DSCP) from DIFFSERV-DSCP-TC [RFC3289] for defining MIB objects that allow for differentiation between various types of traffic in the service provider network.

このMIBモジュールは、直接のPacketCable MTAに関連し、エンドポイントは、独立してサービスを提供それぞれがMTAに支持されている様々なシグナリングMIBオブジェクトを記述する。エンドポイントの認識及び区別は各インデックス(ifIndexの)値は、一意のエンドポイントを指しますifTableを(IF-MIB [RFC2863])を利用することによって作製されます。このMIBモジュールは、サービスプロバイダーネットワークのトラフィックの様々なタイプの間の区別を可能にするMIBオブジェクトを定義するためのDIFFSERV-DSCP-TC [RFC3289]からの差別化サービスコードポイント(DSCP)の構文定義を利用しています。

4.1. Structure of the MIB
4.1. MIBの構造

This MIB module is identified by pktcIetfSigMib and is structured into two major parts:

このMIBモジュールはpktcIetfSigMibによって識別され、2つの主要部分に構成されています。

- Signaling information that controls device and endpoint configuration (pktcSigMibObjects)

- デバイスとエンドポイントの設定を制御シグナリング情報(pktcSigMibObjects)

- Module Conformance information(pktcSigConformance)

- モジュールの適合性情報(pktcSigConformance)

The following sections explain each part in further detail. It is to be noted that future enhancements to specify Notification Objects are also allowed (pktcSigNotification).

以下のセクションでは、さらに詳細に各部を説明します。これは、通知オブジェクトを指定するには、将来の拡張にも(pktcSigNotification)許可されていることに留意すべきです。

4.2. pktcSigMibObjects
4.2. pktcSigMibObjects

This is further divided into device-specific elements (pktcSigDevObjects) and endpoint-specific elements (pktcSigEndPntConfigObjects).

これはさらに、デバイス固有の要素(pktcSigDevObjects)とエンドポイント固有の要素(pktcSigEndPntConfigObjects)に分割されています。

Some highlights of the device-specific elements are as follows:

次のようにデバイス固有の要素のいくつかのハイライトは以下のとおりです。

pktcSigDevCodecTable - this object identifies the codec types available on the device.

pktcSigDevCodecTable - このオブジェクトは、デバイス上で利用可能コーデックの種類を識別します。

pktcSigDevEchoCancellation - this object identifies the capability of echo cancellation on the device.

pktcSigDevEchoCancellation - このオブジェクトはデバイス上のエコーキャンセルの機能を識別します。

pktcSigDevSilenceSuppression - this object specifies if the device is capable of silence suppression (Voice Activity Detection).

pktcSigDevSilenceSuppression - デバイスが無音抑圧(音声アクティビティ検出)することが可能である場合、このオブジェクトが指定します。

pktcSigPulseSignalTable - this table selects the various signals used in the application of the metering pulse signal to the twisted pair line.

pktcSigPulseSignalTable - この表は、ツイストペア線に計量パルス信号のアプリケーションで使用される種々の信号を選択します。

pktcSigDevToneTable - this table specifies a flexible structure within which to specify all of the tones used in the MTA.

pktcSigDevToneTable - この表は、MTAで使用されるトーンのすべてを指定する内柔軟な構造を指定します。

pktcSigDevMultiFreqToneTable - this table defines the characteristics of tones with multiple frequencies. Each entry in this table represents the frequency reference of a multi-frequency tone.

pktcSigDevMultiFreqToneTable - このテーブルは、複数の周波数のトーンの特性を定義します。この表の各エントリは、多周波トーンの周波数基準を表します。

The endpoint-specific elements are mostly confined to the Endpoint configuration MIB table (pktcSigEndPntConfigTable). This table describes the MTA endPoint configuration. The number of entries in this table represents the number of provisioned endpoints.

エンドポイント固有の要素は、主にエンドポイント構成MIBテーブル(pktcSigEndPntConfigTable)に限定されます。このテーブルには、MTAエンドポイント構成を説明します。この表のエントリの数は、プロビジョニングされたエンドポイントの数を表します。

4.3. pktcSigConformance
4.3. pktcSigConformance

pktcSigDeviceGroup - this group contains all the MIB objects that apply on a per-device basis and need to be implemented by an MTA to claim compliance with the specified MIB module.

pktcSigDeviceGroup - このグループは、デバイスごとに適用され、指定されたMIBモジュールの遵守を特徴とするMTAによって実装される必要があるすべてのMIBオブジェクトを含みます。

pktcSigEndpointGroup - this group contains all the MIB objects that apply on a per-endpoint basis and need to be implemented by an MTA to claim compliance with the specified MIB module.

pktcSigEndpointGroup - このグループごとのエンドポイントに基づいて適用され、指定されたMIBモジュールの遵守を特徴とするMTAによって実装される必要があるすべてのMIBオブジェクトを含みます。

pktcLLinePackageGroup - this group contains the MIB objects that need to be implemented to support the L line package.

pktcLLinePackageGroup - このグループはLラインパッケージをサポートするために実装する必要があるMIBオブジェクトが含まれています。

pktcELinePackageGroup - this group contains the MIB objects that need to be implemented to support the E line package.

pktcELinePackageGroup - このグループはEラインパッケージをサポートするために実装する必要があるMIBオブジェクトが含まれています。

pktcInternationalGroup - this group contains optional MIB objects designed to support operations over the widest possible range of markets.

pktcInternationalGroup - このグループは、市場の可能な限り広い範囲に渡って運用をサポートするように設計されたオプションのMIBオブジェクトが含まれています。

5. Definitions
5.定義
PKTC-IETF-SIG-MIB DEFINITIONS ::= BEGIN
        

IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, mib-2 FROM SNMPv2-SMI -- [RFC2578] InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB -- [RFC4001] TEXTUAL-CONVENTION, RowStatus, TruthValue FROM SNMPv2-TC -- [RFC2579]

輸入MODULE-IDENTITY、OBJECT-TYPE、Integer32の、Unsigned32の、MIB-2のSNMPv2-SMI FROM - [RFC2578]のInetAddressType、InetAddressの、InetPortNumber INET-ADDRESS-MIB FROM - SNMPv2のFROM [RFC4001]テキストの表記、RowStatusの、のTruthValue -TC - [RFC2579]

    OBJECT-GROUP,
    MODULE-COMPLIANCE
          FROM SNMPv2-CONF                  -- [RFC2580]
    SnmpAdminString
          FROM SNMP-FRAMEWORK-MIB           -- [RFC3411]
    ifIndex
          FROM IF-MIB                       -- [RFC2863]
    Dscp
          FROM DIFFSERV-DSCP-TC;            -- [RFC3289]
        

pktcIetfSigMib MODULE-IDENTITY LAST-UPDATED "200712180000Z" -- December 18, 2007 ORGANIZATION "IETF IPCDN Working Group" CONTACT-INFO "Sumanth Channabasappa Cable Television Laboratories, Inc. 858 Coal Creek Circle, Louisville, CO 80027, USA Phone: +1 303-661-3307 Email: Sumanth@cablelabs.com

pktcIetfSigMibのMODULE-IDENTITY LAST-UPDATED "200712180000Z" - 2007年12月18日ORGANIZATION "IETF IPCDNワーキンググループ" CONTACT-INFO「スーマンスChannabasappaケーブルテレビラボラトリーズ社858コールクリークサークル、ルイビル、CO 80027、USA電話:+1 303-661-3307 Eメール:Sumanth@cablelabs.com

         Gordon Beacham
         Motorola, Inc.
         6450 Sequence Drive, Bldg. 1
         San Diego, CA 92121, USA
         Phone: +1 858-404-2334
         Email: gordon.beacham@motorola.com
        

Satish Kumar Mudugere Eswaraiah Texas Instruments India (P) Ltd., Golf view, Wind Tunnel Road Murugesh Palya Bangalore 560 017, INDIA Phone: +91 80 5269451 Email: satish.kumar@ti.com

サティシュ・クマールMudugere Eswaraiahテキサス・インスツルメンツインド(P)有限公司、ゴルフビュー、風洞道路Murugesh Palyaバンガロール560 017、インド電話:+91 80 5269451 Eメール:satish.kumar@ti.com

IETF IPCDN Working Group General Discussion: ipcdn@ietf.org Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn Co-Chair: Jean-Francois Mule, jf.mule@cablelabs.com Co-Chair: Richard Woundy, Richard_Woundy@cable.comcast.com"

IETFワーキンググループIPCDN一般的なディスカッション:ipcdn@ietf.org購読:http://www.ietf.org/mailman/listinfo/ipcdnアーカイブ:ftp://ftp.ietf.org/ietf-mail-archive/ipcdn共司会:ジャン=フランソワラバ、jf.mule@cablelabs.com共同議長:リチャードWoundy、Richard_Woundy@cable.comcast.com」

DESCRIPTION "This MIB module supplies the basic management objects for the PacketCable and IPCablecom Signaling protocols. This version of the MIB includes common signaling and Network Call Signaling (NCS)-related signaling objects.

DESCRIPTION「このMIBモジュールはPacketCableおよびIPCablecomシグナリングプロトコルの基本的な管理オブジェクトを供給する。MIBのこのバージョンでは、共通のシグナリングを含み、ネットワーク呼シグナリング(NCS)は、オブジェクトをシグナル - 関連しました。

Copyright (C) The IETF Trust (2008). This version of this MIB module is part of RFC 5098; see the RFC itself for full legal notices." REVISION "200712180000Z" DESCRIPTION "Initial version, published as RFC 5098."

著作権(C)IETFトラスト(2008)。このMIBモジュールのこのバージョンはRFC 5098の一部です。完全な適法な通知についてはRFC自体を参照してください。」REVISION 『200712180000Z』 DESCRIPTION 『初期バージョンは、』 RFC 5098.として公開

::=  { mib-2 169 }
        

-- Textual Conventions

- テキストの表記法

TenthdBm ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d-1"
    STATUS       current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents power levels that are
         normally expressed in dBm.  Units are in tenths of a dBm;
         for example, -13.5 dBm will be represented as -135."
    SYNTAX       Integer32
        
PktcCodecType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        " This TEXTUAL-CONVENTION defines various types of codecs
          that MAY be supported.  The description for each
          enumeration is listed below:
        
          Enumeration     Description
          other           a defined codec not in the enumeration
          unknown         a codec not defined by the PacketCable
                          Codec Specification
          g729            ITU-T Recommendation G.729
          reserved        for future use
          g729E           ITU-T Recommendation G.729E
          pcmu            Pulse Code Modulation u-law (PCMU)
          g726at32        ITU-T Recommendation G.726-32 (32 kbit/s)
          g728            ITU-T Recommendation G.728
          pcma            Pulse Code Modulation a-law (PCMA)
          g726at16        ITU-T Recommendation G.726-16 (16 kbit/s)
          g726at24        ITU-T Recommendation G.726-24 (24 kbit/s)
          g726at40        ITU-T Recommendation G.726-40 (40 kbit/s)
          ilbc            IETF Internet low-bit rate codec
          bv16            Broadcom BroadVoice16
        

The list of codecs is consistent with the IETF Real-Time Transport Protocol (RTP) Profile registry and the RTP Map Parameters Table in PacketCable Audio/Video Codecs Specification [PKT-SP-CODEC]. The literal codec name for each codec is listed below:

コーデックのリストは、IETFリアルタイムトランスポートプロトコル(RTP)のプロファイルレジストリとPacketCableのオーディオ/ビデオコーデック仕様[PKT-SP-CODEC]でRTP地図パラメータ表と一致しています。各コーデックのリテラルのコーデック名は以下の通りであります:

Codec Literal Codec Name g729 G729 g729E G729E pcmu PCMU g726at32 G726-32 g728 G728 pcma PCMA g726at16 G726-16 g726at24 G726-24 g726at40 G726-40 ilbc iLBC bv16 BV16

コーデックリテラルコーデック名G729 G729 g729E G729E PCMU PCMU g726at32 G726-32 g728 G728 PCMA PCMA g726at16 G726-16 g726at24 G726-24 g726at40 G726-40 iLBCのiLBCのbv16 BV16

The literal codec name is the second column of the table with codec RTP Map Parameters. The Literal Codec Name Column contains the codec name used in the local connection options (LCO) of the NCS messages create connection (CRCX)/modify connection (MDCX) and is also used to identify the codec in the Call Management System (CMS) Provisioning Specification. The RTP Map Parameter column of the Table contains the string used in the media attribute line (a=) of the session description protocol (SDP) parameters in NCS messages." SYNTAX INTEGER { other (1), unknown (2), g729 (3), reserved (4), g729E (5), pcmu (6), g726at32 (7), g728 (8), pcma (9), g726at16 (10), g726at24 (11), g726at40 (12), ilbc (13), bv16 (14) }

リテラルのコーデック名はコーデックRTP地図のパラメータを持つテーブルの2番目の列です。リテラルコーデック名列はNCSメッセージのローカル接続オプション(LCO)に接続(CRCX)を作成し使用するコーデック名/変更接続(MDCX)を含み、またコールマネージメントシステム(CMS)のプロビジョニングにコーデックを識別するために使用されます仕様。表のRTP地図パラメータ列は、セッション記述プロトコル(SDP)NCSメッセージ内のパラメータのメディア属性行(=)で使用される文字列が含まれています。」SYNTAX INTEGER {他の(1)、不明(2)、G729( 3)予約(4)、g729E(5)、PCMU(6)、g726at32(7)、g728(8)、PCMA(9)、g726at16(10)、g726at24(11)、g726at40(12)、iLBCの( 13)、bv16(14)}

PktcRingCadence   ::= TEXTUAL-CONVENTION
    STATUS        current
    DESCRIPTION
          "This object provides an encoding scheme for ring cadences, including repeatability characteristics.  All
          fields in this object MUST be encoded in network-byte
          order.
        
          The first three higher-order octets are reserved.  The
          octets that follow are used to encode a 'bit-string', with
          each bit corresponding to 50 milliseconds.  A bit value of
          '1' indicates the presence of a ring-tone, and a bit value
          of '0' indicates the absence of a ring-tone, for that
          duration (50 ms) (Note: A minimum number of octets
          required to encode the bit-string MUST be used).
        

The first two of the reserved octets MUST indicate the length of the encoded cadence (in bits) and MUST range between 1 and 264. (Note: The length in bits MUST also be consistent with the number of octets that encode the cadence). The MTA MUST ignore any unused bits in the last octet, but MUST reflect the value as provided on subsequent SNMP GETs.

予約オクテットの最初の二つは、(ビット)符号化されたケイデンスの長さを示さなければなりませんし、1と264の間の範囲でなければなりません(注:ビット長はまた、ケイデンスをコードオクテットの数と一致していなければなりません)。 MTAは、最後のオクテット内の任意の未使用のビットを無視しなければならないが、その後のSNMP GETを上に提供されるような値を反映しなければなりません。

The third of the reserved octets indicates 'repeatability' and MUST be either 0x80 or 0x00 -- the former value indicating 'non-repeatability', and the latter indicating 'repeatability'.

予約オクテットの第三は、「再現性」を示し、は0x80または0x00のいずれかでなければなりません - 前者の値が「非再現」を示し、後者は「再現性」を示します。

The MTA MUST reject attempts to set a value that violates any of the above requirements."

MTAは、上記の要件のいずれかに違反する値を設定する試みを拒絶しなければなりません。」

SYNTAX OCTET STRING (SIZE(4..36))

構文オクテットSTRING(SIZE(4..36))

PktcSigType     ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        " This object lists the various types of signaling that may
          be supported:
        
          other(1) - set when signaling other than NCS is used
          ncs(2)   - Network Call Signaling is a derivation of MGCP
                    (Media Gateway Control Protocol) defined for
                     IPCablecom/PacketCable MTAs."
    SYNTAX INTEGER {
                   other(1),
                   ncs(2)
    }
        
DtmfCode::=TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents the Dual-Tone
         Multi-Frequency (DTMF) Character used
         to indicate the start or end of the digit transition
         sequence used for caller id or Visual Message Waiting
         Indicator (VMWI).
        

Note: The DTMF code '*' is indicated using 'dtmfcodeStar', and the DTMF code '#' is indicated using ' dtmfcodeHash'." SYNTAX INTEGER { dtmfcode0(0), dtmfcode1(1), dtmfcode2(2), dtmfcode3(3), dtmfcode4(4), dtmfcode5(5), dtmfcode6(6), dtmfcode7(7), dtmfcode8(8), dtmfcode9(9), dtmfcodeStar(10), dtmfcodeHash(11), dtmfcodeA(12), dtmfcodeB(13), dtmfcodeC(14), dtmfcodeD(15) }

'*' DTMFコード 'dtmfcodeStar' を使用して示され、DTMFコード '#' 'はdtmfcodeHash' を使用して示されている「SYNTAX INTEGER {dtmfcode0(0)、dtmfcode1(1)、dtmfcode2(2)、dtmfcode3(注:。 3)、dtmfcode4(4)、dtmfcode5(5)、(6)dtmfcode6、dtmfcode7(7)、dtmfcode8(8)、dtmfcode9(9)、dtmfcodeStar(10)、dtmfcodeHash(11)、dtmfcodeA(12)、dtmfcodeB( 13)、dtmfcodeC(14)、dtmfcodeD(15)}

PktcSubscriberSideSigProtocol::=TEXTUAL-CONVENTION
    STATUS  current
    DESCRIPTION
        "This TEXTUAL-CONVENTION represents the Signaling
         protocol being used for purposes such as caller id
         or VMWI.
        
         A value of fsk(1) indicates Frequency Shift Keying
         (FSK).
         A value of dtmf(2) indicates Dual-Tone Multi-Frequency
         (DTMF)."
         SYNTAX INTEGER {
                fsk(1),
                dtmf(2)
         }
        
pktcSigMibObjects OBJECT IDENTIFIER ::= { pktcIetfSigMib 1 }
pktcSigDevObjects OBJECT IDENTIFIER ::=
        
                                        { pktcSigMibObjects 1 }
pktcSigEndPntConfigObjects OBJECT IDENTIFIER ::=
                                        { pktcSigMibObjects 2 }
--
-- The codec table (pktcSigDevCodecTable) defines all combinations
-- of codecs supported by the Multimedia Terminal Adapter (MTA).
--
pktcSigDevCodecTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PktcSigDevCodecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
         " This table describes the MTA-supported codec types.  An MTA
          MUST populate this table with all possible combinations of
          codecs it supports for simultaneous operation.  For example,
          an MTA with two endpoints may be designed with a particular
          Digital Signal Processing (DSP) and memory architecture that
          allows it to support the following fixed combinations of
          codecs for simultaneous operation:
        
          Codec Type     Maximum Number of Simultaneous Codecs
          PCMA                             3
        

PCMA 2 PCMU 1

BCMA 2 PCMU 1

PCMA 1

PCMA 1

PCMU 2

PCMU 2

PCMU 3

PCMU 3

PCMA 1 G729 1

バスマ1 Juhas 1

G729 2

Juhas A

PCMU 1 G729 1

1 Juhas 1の名前で

Based on this example, the entries in the codec table would be:

この例に基づいて、コーデックテーブルのエントリは次のようになります。

pktcSigDev pktcSigDev pktcSigDev CodecComboIndex CodecType CodecMax 1 pcma 3 2 pcma 2 2 pcmu 1

pktcSigDev pktcSigDev pktcSigDev CodecComboIndex CodecType CodecMax 1 PCMA 3 2 PCMA 2 2 PCMU 1

                 3               pcma                1
                 3               pcmu                2
                 4               pcmu                3
                 5               pcma                1
                 5               g729                1
                 6               g729                2
                 7               pcmu                1
                 7               g729                1
        

An operator querying this table is able to determine all possible codec combinations the MTA is capable of simultaneously supporting.

このテーブルを照会オペレータは、MTAを同時にサポートすることができるすべての可能なコーデックの組み合わせを決定することができます。

          This table MUST NOT include non-voice codecs."
    ::= { pktcSigDevObjects 1 }
        
pktcSigDevCodecEntry  OBJECT-TYPE
    SYNTAX      PktcSigDevCodecEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Each entry represents the maximum number of active
         connections with a particular codec the MTA is capable of
         supporting.  Each row is indexed by a composite key
         consisting of a number enumerating the particular codec
         combination and the codec type."
    INDEX { pktcSigDevCodecComboIndex, pktcSigDevCodecType }
    ::= { pktcSigDevCodecTable 1 }
        
PktcSigDevCodecEntry  ::= SEQUENCE {
    pktcSigDevCodecComboIndex    Unsigned32,
    pktcSigDevCodecType     PktcCodecType,
    pktcSigDevCodecMax      Unsigned32
    }
        
pktcSigDevCodecComboIndex  OBJECT-TYPE
    SYNTAX      Unsigned32 (1..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        " The index value that enumerates a particular codec
          combination in the pktcSigDevCodecTable."
    ::= { pktcSigDevCodecEntry 1 }
        

pktcSigDevCodecType OBJECT-TYPE SYNTAX PktcCodecType MAX-ACCESS not-accessible STATUS current

pktcSigDevCodecTypeのOBJECT-TYPE SYNTAX PktcCodecType MAX-ACCESSステータス現在の

    DESCRIPTION
        " A codec type supported by this MTA."
    ::= { pktcSigDevCodecEntry 2 }
        
pktcSigDevCodecMax  OBJECT-TYPE
    SYNTAX      Unsigned32(1..255)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        " The maximum number of simultaneous sessions of a
          particular codec that the MTA can support."
    ::= { pktcSigDevCodecEntry 3 }
        

-- -- These are the common signaling-related definitions that affect -- the entire MTA device. --

- - 全体MTAデバイス - これらは影響共通シグナリング関連の定義があります。 -

pktcSigDevEchoCancellation  OBJECT-TYPE
    SYNTAX       TruthValue
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This object specifies if the device is capable of echo
          cancellation.  The MTA MUST set this MIB object to a
          value of true(1) if it is capable of echo
          cancellation, and a value of false(2) if not."
    ::= { pktcSigDevObjects 2 }
        
pktcSigDevSilenceSuppression  OBJECT-TYPE
    SYNTAX       TruthValue
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This object specifies if the device is capable of
          silence suppression (as a result of Voice Activity
          Detection).  The MTA MUST set this MIB object to a
          value of true(1) if it is capable of silence
          suppression, and a value of false(2) if not."
::= { pktcSigDevObjects 3 }
        

pktcSigDevCidSigProtocol OBJECT-TYPE SYNTAX PktcSubscriberSideSigProtocol MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to configure the subscriber-line protocol used for signaling on-hook caller id information.

pktcSigDevCidSigProtocol OBJECT-TYPE構文PktcSubscriberSideSigProtocol MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトがオンフック発信者ID情報をシグナリングするために使用される加入者線プロトコルを設定するために使用されます。

         Different countries define different caller id signaling
         protocols to support caller identification.
        

Setting this object at a value fsk(1) sets the subscriber line protocol to be Frequency Shift Keying (FSK).

値FSK(1)にこのオブジェクトを設定する(FSK)加入者線プロトコルは周波数偏移変調であることを設定します。

Setting this object at a value dtmf(2) sets the subscriber line protocol to be Dual-Tone Multi-Frequency (DTMF).

値DTMF(2)にこのオブジェクトを設定するデュアルトーン多重周波数(DTMF)と加入者線プロトコルを設定します。

         The value of this MIB object MUST NOT persist across MTA
         reboots."
     REFERENCE
        "ETSI-EN-300-659-1 Specification"
     DEFVAL { fsk }
::= { pktcSigDevObjects 4 }
        

pktcSigDevR0Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 0 (a user-defined field).

pktcSigDevR0Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音0(ユーザー定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 5 }
        

pktcSigDevR1Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 1 (a user-defined field).

pktcSigDevR1Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音1(ユーザ定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 6 }
        

pktcSigDevR2Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 2 (a user-defined field).

pktcSigDevR2Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音2(ユーザー定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 7 }
        

pktcSigDevR3Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 3 (a user-defined field).

pktcSigDevR3Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音3(ユーザー定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 8 }
        

pktcSigDevR4Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 4 (a user-defined field).

pktcSigDevR4Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音4(ユーザー定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 9 }
        

pktcSigDevR5Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 5 (a user-defined field).

pktcSigDevR5Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音5(ユーザー定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 10 }
        

pktcSigDevR6Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 6 (a user-defined field).

pktcSigDevR6Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音6(ユーザ定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 11 }
        

pktcSigDevR7Cadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence 7 (a user-defined field).

pktcSigDevR7Cadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音7(ユーザ定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 12 }
        

pktcSigDevRgCadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence rg (a user-defined field).

pktcSigDevRgCadence OBJECT-TYPE構文PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、呼び出し音のRG(ユーザ定義フィールド)を指定します。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 13 }
        

pktcSigDevRsCadence OBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies ring cadence rs (a user-defined field). The MTA MUST reject any attempt to make this object repeatable.

pktcSigDevRsCadenceのOBJECT-TYPE SYNTAX PktcRingCadence MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはリングリズムのRS(ユーザー定義フィールド)を指定します。MTAは、このオブジェクトが反復可能しようとする試みを拒絶しなければなりません。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    ::= { pktcSigDevObjects 14 }
        

pktcSigDefCallSigDscp OBJECT-TYPE SYNTAX Dscp -- RFC 3289: DIFFSERV-DSCP-TC MAX-ACCESS read-write STATUS current DESCRIPTION " The default value used in the IP header for setting the Differentiated Services Code Point (DSCP) value for call signaling.

pktcSigDefCallSigDscpのOBJECT-TYPE SYNTAXもDscp - RFC 3289:DIFFSERV-DSCP-TC MAX-ACCESS読み取りと書き込みステータス現在の説明「コールシグナリングのための差別化サービスコードポイント(DSCP)値を設定するためのIPヘッダーで使用されるデフォルト値。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    DEFVAL { 0 }
    ::= { pktcSigDevObjects 15 }
        

pktcSigDefMediaStreamDscp OBJECT-TYPE SYNTAX Dscp -- RFC 3289: DIFFSERV-DSCP-TC MAX-ACCESS read-write STATUS current DESCRIPTION " This object contains the default value used in the IP header for setting the Differentiated Services Code Point (DSCP) value for media stream packets. The MTA MUST NOT update this object with the value supplied by the CMS in the NCS messages (if present). Any currently active connections are not affected by updates to this object. When the value of this object is updated by SNMP, the MTA MUST use the new value as a default starting only from new connections.

pktcSigDefMediaStreamDscpのOBJECT-TYPE SYNTAXもDscp - RFC 3289:DIFFSERV-DSCP-TC MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、メディアのための差別化サービスコードポイント(DSCP)値を設定するためのIPヘッダーで使用されるデフォルト値が含まれていますストリームパケット。MTAはNCSメッセージ(存在する場合)にはCMSによって提供された値で、このオブジェクトをアップデートしてはいけません。現在アクティブな接続は、このオブジェクトへの更新による影響を受けません。このオブジェクトの値はSNMPによって更新されると、 MTAは新しい接続だけから始まるデフォルトとして新しい値を使用しなければなりません。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    DEFVAL { 0 }
    ::= { pktcSigDevObjects 16 }
        

-- -- pktcSigCapabilityTable - This table defines the valid signaling -- types supported by this MTA. --

- - pktcSigCapabilityTable - このMTAでサポートされているタイプ - このテーブルには、有効なシグナルを定義します。 -

pktcSigCapabilityTable    OBJECT-TYPE
    SYNTAX        SEQUENCE OF PktcSigCapabilityEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " This table describes the signaling types supported by this
          MTA."
    ::= { pktcSigDevObjects 17 }
        
pktcSigCapabilityEntry    OBJECT-TYPE
    SYNTAX        PktcSigCapabilityEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " Entries in pktcMtaDevSigCapabilityTable - list of
          supported signaling types, versions, and vendor extensions for this MTA.  Each entry in the list provides for one
          signaling type and version combination.  If the device
          supports multiple versions of the same signaling type, it
          will require multiple entries."
    INDEX { pktcSigCapabilityIndex }
    ::= { pktcSigCapabilityTable 1 }
        
PktcSigCapabilityEntry  ::= SEQUENCE {
    pktcSigCapabilityIndex             Unsigned32,
    pktcSigCapabilityType              PktcSigType,
    pktcSigCapabilityVersion           SnmpAdminString,
    pktcSigCapabilityVendorExt         SnmpAdminString
    }
        
pktcSigCapabilityIndex       OBJECT-TYPE
    SYNTAX        Unsigned32 (1..255)
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " The index value that uniquely identifies an entry in the
          pktcSigCapabilityTable."
    ::= { pktcSigCapabilityEntry 1 }
        
pktcSigCapabilityType      OBJECT-TYPE
    SYNTAX        PktcSigType
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        " This object identifies the type of signaling used.  This
          value has to be associated with a single signaling
          version."
    ::= { pktcSigCapabilityEntry 2 }
        
pktcSigCapabilityVersion      OBJECT-TYPE
    SYNTAX        SnmpAdminString
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION
        " Provides the version of the signaling type - reference
          pktcSigCapabilityType.  Examples would be 1.0 or 2.33 etc."
    ::= { pktcSigCapabilityEntry 3 }
        

pktcSigCapabilityVendorExt OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION " The vendor extension allows vendors to provide a list of

pktcSigCapabilityVendorExt OBJECT-TYPE SYNTAXれるSnmpAdminString MAX-ACCESS read-onlyステータス現在の説明「ベンダー拡張は、ベンダーがのリストを提供することができます

additional capabilities.

追加機能。

The syntax for this MIB object in ABNF ([RFC5234]) is specified to be zero or more occurrences of vendor extensions, as follows:

次のようにABNF([RFC5234])で、このMIBオブジェクトの構文は、ベンダー拡張の0回以上の繰り返しであることが指定されています。

pktcSigCapabilityVendorExt = *(vendor-extension) vendor-extension = (ext symbol alphanum) DQUOTE ; DQUOTE ext = DQUOTE %x58 DQUOTE symbol = (DQUOTE %x2D DQUOTE)/(DQUOTE %x2D DQUOTE) alphanum = 1*6(ALPHA/DIGIT)

pktcSigCapabilityVendorExt = *(ベンダー拡張)ベンダー拡張=(EXTシンボルalphanum)DQUOTE。 DQUOTEのEXT = DQUOTE%X58 DQUOTEシンボル=(DQUOTE%x2D DQUOTE)/(DQUOTE%のx2D DQUOTE)alphanum = 1 * 6(ALPHA / DIGIT)

        "
    ::= { pktcSigCapabilityEntry 4 }
        

pktcSigDefNcsReceiveUdpPort OBJECT-TYPE SYNTAX InetPortNumber (1025..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " This object contains the MTA User Datagram Protocol (UDP) receive port that is being used for NCS call signaling. This object should only be changed by the configuration file.

pktcSigDefNcsReceiveUdpPortのOBJECT-TYPE SYNTAX InetPortNumber(1025..65535)MAX-ACCESS read-onlyステータス現在の説明は「このオブジェクトは、MTAのユーザーデータグラムプロトコル(UDP)は、シグナリングNCSコールに使用されている受信ポートが含まれています。このオブジェクトは変更する必要があります設定ファイルによって。

          Unless changed via configuration, this MIB object MUST
          reflect a value of '2427'."
    REFERENCE
        "PacketCable NCS Specification"
    ::= { pktcSigDevObjects 18 }
        

pktcSigPowerRingFrequency OBJECT-TYPE SYNTAX INTEGER { f20Hz(1), f25Hz(2), f33Point33Hz(3), f50Hz(4), f15Hz(5), f16Hz(6), f22Hz(7), f23Hz(8), f45Hz(9) } MAX-ACCESS read-only STATUS current DESCRIPTION " This object must only be provided via the configuration file during the provisioning process. The power ring frequency is the frequency at which the sinusoidal voltage must travel down the twisted pair to make terminal equipment ring. Different countries define different electrical characteristics to make terminal equipment ring.

(5)、f16Hz(6)、f22Hz(7)、f23Hz(8)、f45Hz pktcSigPowerRingFrequencyのOBJECT-TYPE SYNTAX INTEGER {f20Hz(1)、f25Hz(2)、f33Point33Hz(3)、f50Hz(4)、f15Hz(9 )} MAX-ACCESS read-only説明「このオブジェクトのみプロビジョニング・プロセス中に、構成ファイルを介して提供されなければならない。パワーリング周波数は、正弦波電圧が端末装置のリングを作るためにツイストペアを下に移動しなければならない頻度であります。さまざまな国では、端末機器のリングを作るために異なる電気的特性を定義します。

          The f20Hz setting corresponds to a power ring frequency
          of 20 Hertz.  The f25Hz setting corresponds to a power ring
          frequency of 25 Hertz.  The f33Point33Hz setting
          corresponds to a power ring frequency of 33.33 Hertz.  The
          f50Hz setting corresponds to a power ring frequency of 50
          Hertz.  The f15Hz setting corresponds to a power ring
          frequency of 15 Hertz.  The f16Hz setting corresponds to a
          power ring frequency of 16 Hertz.  The f22Hz setting
          corresponds to a power ring frequency of 22 Hertz.  The
          f23Hz setting corresponds to a power ring frequency of 23
          Hertz.  The f45Hz setting corresponds to a power ring
          frequency of 45 Hertz."
    REFERENCE
          "ETSI-EN-300-001"
    ::= { pktcSigDevObjects 19 }
        
pktcSigPulseSignalTable    OBJECT-TYPE
    SYNTAX       SEQUENCE OF PktcSigPulseSignalEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " The Pulse signal table defines the pulse signal operation.
          There are nine types of international pulse signals,
          with each signal having a set of provisionable parameters.
          The values of the MIB objects in this table take effect
          only if these parameters are not defined via signaling, in
          which case, the latter determines the values of the
          parameters.  The MIB objects in this table do not persist
          across MTA reboots."
    REFERENCE
        "ETSI-TS-101-909-4 Specification"
    ::= { pktcSigDevObjects 20 }
        

pktcSigPulseSignalEntry OBJECT-TYPE SYNTAX PktcSigPulseSignalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This object defines the set of parameters associated with each particular value of pktcSigPulseSignalType. Each entry in the pktcSigPulseSignalTable is indexed by the pktcSigPulseSignalType object.

pktcSigPulseSignalEntry OBJECT-TYPE構文PktcSigPulseSignalEntry MAX-ACCESSステータス現在の説明は「このオブジェクトpktcSigPulseSignalTypeのそれぞれの特定の値に関連付けられたパラメータのセットを定義する。pktcSigPulseSignalTableにおける各エントリはpktcSigPulseSignalTypeオブジェクトによってインデックスされます。

          The conceptual rows MUST NOT persist across MTA reboots."
    INDEX { pktcSigPulseSignalType }
    ::= { pktcSigPulseSignalTable 1 }
        
PktcSigPulseSignalEntry ::= SEQUENCE {
        pktcSigPulseSignalType              INTEGER,
        pktcSigPulseSignalFrequency         INTEGER,
        pktcSigPulseSignalDbLevel           TenthdBm,
        pktcSigPulseSignalDuration          Unsigned32,
        pktcSigPulseSignalPulseInterval     Unsigned32,
        pktcSigPulseSignalRepeatCount       Unsigned32
}
        

pktcSigPulseSignalType OBJECT-TYPE SYNTAX INTEGER { initialRing(1), pulseLoopClose(2), pulseLoopOpen(3), enableMeterPulse(4), meterPulseBurst(5), pulseNoBattery(6), pulseNormalPolarity(7), pulseReducedBattery(8), pulseReversePolarity(9) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "There are nine types of international pulse signals. These signals are defined as follows: initial ring pulse loop close pulse loop open enable meter pulse meter pulse burst pulse no battery pulse normal polarity pulse reduced battery pulse reverse polarity" REFERENCE "ETSI-EN-300-324-1 Specification"

pktcSigPulseSignalTypeのOBJECT-TYPE SYNTAX INTEGER {initialRing(1)、pulseLoopClose(2)、pulseLoopOpen(3)、enableMeterPulse(4)、meterPulseBurst(5)、pulseNoBattery(6)、pulseNormalPolarity(7)、pulseReducedBattery(8)、pulseReversePolarity(9 )} MAX-ACCESSステータス現在の説明は「国際的なパルス信号の9種類があり、以下のようにこれらの信号は、定義されます。初期環パルスループ近いパルスループは、メータパルスメータパルスを有効に開く低下なし電池パルス正常極性パルスをパルスしないバーストバッテリーパルス逆極性」REFERENCE "ETSI-EN-300-324-1仕様"

    ::= { pktcSigPulseSignalEntry 1 }
        

pktcSigPulseSignalFrequency OBJECT-TYPE SYNTAX INTEGER { twentyfive(1), twelvethousand(2), sixteenthousand(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object is only applicable to the initialRing, enableMeterPulse, and meterPulseBurst signal types. This object identifies the frequency of the generated signal. The following table defines the default values for this object depending on signal type:

pktcSigPulseSignalFrequencyのOBJECT-TYPE SYNTAX INTEGER {twentyfive(1)、twelvethousand(2)、sixteenthousand(3)} MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはinitialRing、enableMeterPulse、及びmeterPulseBurst信号タイプにのみ適用可能である。この目的生成された信号の周波数を識別する次の表は、信号の種類に応じて、このオブジェクトのデフォルト値を定義します:

          pktcSigPulseSignalType     Default
          initialRing                25
          enableMeterPulse           16000
          meterPulseBurst            16000
        
          The value of twentyfive MUST only be used for the
          initialRing signal type.  The values of twelvethousand and
          sixteenthousand MUST only be used for enableMeterPulse and
          meterPulseBurst signal types.  An attempt to set this
          object while the value of pktcSigPulseSignalType is not
          initialRing, enableMeterPulse, or meterPulseBurst will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-001 Specification"
         ::= { pktcSigPulseSignalEntry 2}
        

pktcSigPulseSignalDbLevel OBJECT-TYPE SYNTAX TenthdBm (-350..0) UNITS "1/10 of a dBm" MAX-ACCESS read-write STATUS current DESCRIPTION " This object is only applicable to the enableMeterPulse and meterPulseBurst signal types. This is the decibel level for each frequency at which tones could be generated at the a and b terminals (TE connection point). An attempt to set this object while the value of pktcSigPulseSignalType is not enableMeterPulse or meterPulseBurst will result in an 'inconsistentValue' error." REFERENCE "ETSI-EN-300-001 Specification"

pktcSigPulseSignalDbLevel OBJECT-TYPE構文TenthdBm(-350..0)単位MAX-ACCESS読み取りと書き込みSTATUS「dBm単位の1/10が」現在の説明は「このオブジェクトはenableMeterPulseとmeterPulseBurst信号タイプにのみ適用可能である。これは、デシベルレベルであります周波数毎にトーンがAとB端子(TEの接続点)で生成することができるれる。pktcSigPulseSignalTypeの値がenableMeterPulse又はmeterPulseBurstないが、このオブジェクトを設定する試みは「はinconsistentValue」エラーになります。」 REFERENCE "ETSI-EN-300から001の仕様"

    DEFVAL { -135 }
    ::={pktcSigPulseSignalEntry 3 }
        

pktcSigPulseSignalDuration OBJECT-TYPE

pktcSigPulseSignalDurationのOBJECT-TYPE

    SYNTAX       Unsigned32 (0..5000)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the pulse duration for each
          signal type.  In addition, the MTA must accept the values
          in the incremental steps specific for each signal type.
          The following table defines the default values and the
          incremental steps for this object depending on the signal
          type:
        
          pktcSigPulseSignaltype  Default (ms)   Increment (ms)
          initialRing                 200             50
          pulseLoopClose              200             10
          pulseLoopOpen               200             10
          enableMeterPulse            150             10
          meterPulseBurst             150             10
          pulseNoBattery              200             10
          pulseNormalPolarity         200             10
          pulseReducedBattery         200             10
          pulseReversePolarity        200             10
        
          An attempt to set this object to a value that does not
          fall on one of the increment boundaries, or on the wrong
          increment boundary for the specific signal type, will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-324-1 Specification"
         ::= {pktcSigPulseSignalEntry 4 }
        

pktcSigPulseSignalPulseInterval OBJECT-TYPE SYNTAX Unsigned32 (0..5000) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the repeat interval, or the period, for each signal type. In addition, the MTA must accept the values in the incremental steps specific for each signal type. The following table defines the default values and the incremental steps for this object, depending on the signal type:

pktcSigPulseSignalPulseInterval OBJECT-TYPE構文Unsigned32(0..5000)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、各信号タイプのために、繰り返し間隔または期間を指定する。さらに、MTAは受け入れなければなりません各信号タイプのための特定の増分ステップの値以下の表は、信号の種類に応じて、このオブジェクトのデフォルト値及び増分ステップを定義しています。

          pktcSigPulseSignaltype  Default (ms)   Increment (ms)
          initialRing                 200             50
          pulseLoopClose             1000             10
          pulseLoopOpen              1000             10 enableMeterPulse           1000             10
          meterPulseBurst            1000             10
          pulseNoBattery             1000             10
          pulseNormalPolarity        1000             10
          pulseReducedBattery        1000             10
          pulseReversePolarity       1000             10
        
          An attempt to set this object to a value that does not
          fall on one of the increment boundaries, or on the wrong
          increment boundary for the specific signal type, will
          result in an 'inconsistentValue' error."
    REFERENCE
        "ETSI-EN-300-324-1 Specification"
         ::= { pktcSigPulseSignalEntry 5}
        

pktcSigPulseSignalRepeatCount OBJECT-TYPE SYNTAX Unsigned32 (1..50) MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies how many times to repeat a pulse. This object is not used by the enableMeterPulse signal type, and in that case, the value is irrelevant. The following table defines the default values and the valid ranges for this object, depending on the signal type:

pktcSigPulseSignalRepeatCount OBJECT-TYPE構文Unsigned32(1..50)MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはパルスを繰り返す回数を指定する。この目的はenableMeterPulse信号タイプによって使用されず、その場合に、値は無関係である次の表では、信号の種類に応じて、このオブジェクトのデフォルト値および有効範囲を定義します:

pktcSigPulseSignaltype Default Range

pktcSigPulseSignaltypeデフォルトの範囲

initialRing 1 1-5 pulseLoopClose 1 1-50 pulseLoopOpen 1 1-50 enableMeterPulse (any value)(but not used) meterPulseBurst 1 1-50 pulseNoBattery 1 1-50 pulseNormalPolarity 1 1-50 pulseReducedBattery 1 1-50 pulseReversePolarity 1 1-50

1 1-5 pulseLoopClose 1 1-50 pulseLoopOpen 1 1-50 enableMeterPulse(任意の値)initialRing(ただし、使用)meterPulseBurst 1 1-50 pulseNoBattery 1 1-50 pulseNormalPolarity 1 1-50 pulseReducedBattery 1 1-50 pulseReversePolarity 1 1-50

          An attempt to set this object to a value that does not
          fall within the range for the specific
          signal type will result in an 'inconsistentValue' error."
    ::={ pktcSigPulseSignalEntry 6 }
        

pktcSigDevCidMode OBJECT-TYPE SYNTAX INTEGER { duringRingingETS(1), dtAsETS(2), rpAsETS(3), lrAsETS(4), lrETS(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " For on-hook caller id, pktcSigDevCidMode selects the method for representing and signaling caller identification. For the duringRingingETS method, the Frequency Shift Keying (FSK) or the Dual-Tone Multi-Frequency (DTMF) containing the caller identification information is sent between the first and second ring pattern.

pktcSigDevCidModeのOBJECT-TYPE SYNTAX INTEGER {duringRingingETS(1)、dtAsETS(2)、rpAsETS(3)、lrAsETS(4)、lrETS(5)}オンフック発信者ID、pktcSigDevCidModeについてMAX-ACCESS読み取りと書き込みステータス現在の説明 "表現及び発信者識別情報をシグナリングするための方法を選択する。duringRingingETS方法については、発呼者識別情報を含む周波数シフトキーイング(FSK)、又はデュアルトーン多重周波数(DTMF)は、第一および第二のリングパターン間で送信されます。

          For the dtAsETS,rpAsETS, lrAsETS and lrETS
          methods, the FSK or DTMF containing the caller id
          information is sent before the first ring pattern.
        

For the dtAsETS method, the FSK or DTMF is sent after the Dual Tone Alert Signal. For the rpAsETS method, the FSK or DTMF is sent after a Ring Pulse.

dtAsETS方法については、FSKまたはDTMFは、デュアルトーン警報信号の後に送信されます。 rpAsETS方法については、FSKまたはDTMFは、リングパルスの後に送信されます。

For the lrAsETS method, the Line Reversal occurs first, then the Dual Tone Alert Signal, and, finally, the FSK or DTMF is sent.

lrAsETS方法については、ライン反転は最終的に、FSKまたはDTMFが送信され、その後、最初のデュアルトーン警報信号を発生し、。

For the lrETS method, the Line Reversal occurs first, then the FSK or DTMF is sent.

lrETS方法に、ライン反転は、その後、FSKまたはDTMFが送信され、最初に発生します。

The value of this MIB object MUST NOT persist across MTA reboots."

このMIBオブジェクトの値はMTAのリブートを渡って持続してはいけません。」

    DEFVAL { rpAsETS}
    ::= {pktcSigDevObjects 21 }
        

pktcSigDevCidAfterRing OBJECT-TYPE SYNTAX Unsigned32 (0|50..2000) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of first ringing pattern and the start of the transmission of the FSK or DTMF containing the caller id information. It is only used when pktcSigDevCidMode is set to a value of 'duringRingingETS'.

OBJECT-TYPE構文Unsigned32(0 | 50..2000)pktcSigDevCidAfterRing UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクト最初のリンギングパターンの端とFSKの送信の開始との間の遅延を指定し又はDTMFは、発信者ID情報を含む。pktcSigDevCidMode「はduringRingingETS」の値に設定されているときにのみ使用されます。

          The following table defines the default values
          for this MIB object, depending on the signal type
        

(pktcSigDevCidMode), and MUST be followed:

(pktcSigDevCidMode)、及びに従う必要があります。

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS 550 ms dtAsETS any value (not used) rpAsETS any value (not used) lrAsETS any value (not used) lrETS any value (not used)

duringringingETS 550ミリ秒dtAsETS(使用しない)任意の値(使用しない)任意の値をrpAsETS(使用しない)任意の値をlrAsETS(使用しない)任意の値をlrETS

An attempt to set this object while the value of pktcSigDevCidMode is not duringringingETS will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値がduringringingETSない間にこのオブジェクトを設定する試みはから「inconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 550 }
    ::= {pktcSigDevObjects 22 }
        

pktcSigDevCidAfterDTAS OBJECT-TYPE SYNTAX Unsigned32 (0|45..500) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of the Dual Tone Alert Signal (DT-AS) and the start of the transmission of the FSK or DTMF containing the caller id information. This object is only used when pktcSigDevCidMode is set to a value of 'dtAsETS' or 'lrAsETS'.

pktcSigDevCidAfterDTAS OBJECT-TYPE構文Unsigned32(0 | 45..500)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはデュアルトーン警報信号(DT-AS)の終了と開始の間の遅延を指定しますpktcSigDevCidModeが「dtAsETS」または「lrAsETS」の値に設定されている場合、発信者ID情報を含むFSKまたはDTMFの送信。この目的にのみ使用されます。

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:
        

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS 50 ms rpAsETS any value (not used) lrAsETS 50 ms lrETS any value (not used)

いずれかの値が(使用しない)50ミリ秒rpAsETS(使用しない)任意の値50ミリ秒lrETS任意の値をlrAsETSをdtAsETS duringringingETS(未使用)

An attempt to set this object while the value of pktcSigDevCidMode is not 'dtAsETS' or 'lrAsETS' will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値が「dtAsETS」または「lrAsETS」でないときにこのオブジェクトを設定する試みはから「inconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 50 }
    ::= {pktcSigDevObjects 23 }
        

pktcSigDevCidAfterRPAS OBJECT-TYPE SYNTAX Unsigned32 (0|500..800) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of the Ring Pulse Alert Signal (RP-AS) and the start of the transmission of the FSK or DTMF containing the caller id information. This MIB object is only used when pktcSigDevCidMode is set to a value of 'rpAsETS'. The following table defines the default values for this MIB object, depending on the signal type (pktcSigDevCidMode), and MUST be followed:

pktcSigDevCidAfterRPASのOBJECT-TYPE構文Unsigned32(0 | 500..800)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、リングパルス警報信号(RP-AS)の終了と開始の間の遅延を指定しますpktcSigDevCidMode「はrpAsETS」の値に設定されている場合、発信者ID情報を含むFSKまたはDTMFの送信。このMIBオブジェクトにのみ使用される。以下の表は、(信号の種類に応じて、このMIBオブジェクトのデフォルト値を定義しますpktcSigDevCidMode)、およびに従う必要があります。

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS any value (not used) rpAsETS 650 ms lrAsETS any value (not used) lrETS any value (not used)

いずれかの値が(使用しない)任意の値を(未使用)650ミリ秒lrAsETS(使用しない)任意の値をrpAsETS任意の値をlrETS dtAsETS duringringingETS(未使用)

An attempt to set this object while the value of pktcSigDevCidMode is not 'rpAsETS' will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値がない間、このオブジェクトを設定する試みは、「rpAsETSは」「はinconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 650 }
    ::= {pktcSigDevObjects 24 }
        

pktcSigDevRingAfterCID OBJECT-TYPE SYNTAX Unsigned32 (0|50..500) UNITS "Milliseconds" MAX-ACCESS read-write

pktcSigDevRingAfterCID OBJECT-TYPE構文Unsigned32(0 | 50..500)UNITS "ミリ秒" MAX-ACCESSの読み取りと書き込み

    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          complete transmission of the FSK or DTMF containing the
          caller id information and the start of the first ring
          pattern.  It is only used when pktcSigDevCidMode is
          set to a value of 'dtAsETS', 'rpAsETS', 'lrAsETS' or
          'lrETS'.
        
          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:
        

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS 250 ms rpAsETS 250 ms lrAsETS 250 ms lrETS 250 ms

duringringingETS(使用されない)の任意の値は、250ミリ秒rpAsETS 250ミリlrAsETS 250ミリlrETS 250ミリ秒dtAsETS

An attempt to set this object while the value of pktcSigDevCidMode is not 'dtAsETS', 'rpAsETS', 'lrAsETS', or 'lrETS' will result in an 'inconsistent value' error.

pktcSigDevCidModeの値が「dtAsETS」、「rpAsETS」はないが、このオブジェクトを設定する試みは、「lrAsETS」、または「lrETS」「は一貫性のない値」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 250 }
    ::= {pktcSigDevObjects 25 }
        

pktcSigDevCidDTASAfterLR OBJECT-TYPE SYNTAX Unsigned32 (50..655) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of the Line Reversal and the start of the Dual Tone Alert Signal (DT-AS). This object is only used when pktcSigDevCidMode is set to a value of 'lrAsETS'.

pktcSigDevCidDTASAfterLRのOBJECT-TYPE構文Unsigned32(50..655)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはライン反転の終了およびデュアルトーン警報信号の開始との間の遅延を指定します(DT- pktcSigDevCidModeが「lrAsETS」の値に設定されている場合)など。このオブジェクトは使用されています。

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevCidMode), and MUST be followed:
        

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS any value (not used) rpAsETS any value (not used) lrAsETS 250 ms lrETS any value (not used)

いずれかの値が(使用されない)任意の値(使用されていない)をdtAsETS任意の値を(未使用)250ミリ秒lrETS任意の値をlrAsETS rpAsETS duringringingETS(未使用)

An attempt to set this object while the value of pktcSigDevCidMode is not lrAsETS will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値がlrAsETSない間にこのオブジェクトを設定する試みはから「inconsistentValue」エラーになります。

The value of this MIB object MUST NOT persist across MTA reboots." REFERENCE "ETSI-EN-300-659-1 Specification" DEFVAL { 250 }

MTAは、リブートを横切ってこのMIBオブジェクトの値が持続してはいけません。」REFERENCE "ETSI-EN-300-659-1仕様" DEFVAL {250}

    ::= {pktcSigDevObjects 26 }
        

pktcSigDevVmwiMode OBJECT-TYPE SYNTAX INTEGER { dtAsETS(1), rpAsETS(2), lrAsETS(3), osi(4), lrETS(5) } MAX-ACCESS read-write STATUS current DESCRIPTION " For visual message waiting indicator (VMWI), pktcSigDevVmwiMode selects the alerting signal method. For the dtAsETS, rpAsETS, lrAsETS, osi, and lrETS methods, the FSK containing the VMWI information is sent after an alerting signal.

pktcSigDevVmwiModeのOBJECT-TYPE SYNTAX INTEGER {dtAsETS(1)、rpAsETS(2)、lrAsETS(3)、OSI(4)、lrETS(5)}ビジュアルメッセージ待機インジケータについてMAX-ACCESS読み取りと書き込みステータス現在の説明「(VMWI) 、pktcSigDevVmwiModeは警告信号方式を選択する。dtAsETS、rpAsETS、lrAsETS、OSI、およびlrETS方法については、VMWI情報を含むFSKは、警告信号の後に送信されます。

          For the dtAsETS method, the FSK, or DTMF
          is sent after the Dual Tone Alert Signal.  For the rpAsETS
          method, the FSK or DTMF is sent after a Ring Pulse.
        

For the lrAsETS method, the Line Reversal occurs first, then the Dual Tone Alert Signal, and, finally, the FSK or DTMF is sent.

lrAsETS方法については、ライン反転は最終的に、FSKまたはDTMFが送信され、その後、最初のデュアルトーン警報信号を発生し、。

For the OSI method, the FSK or DTMF is sent after the Open Switching Interval.

OSIの方法については、FSKまたはDTMFはオープン間隔を切り替えた後送信されます。

For the lrETS method, the Line Reversal occurs first, then the FSK or DTMF is sent.

lrETS方法に、ライン反転は、その後、FSKまたはDTMFが送信され、最初に発生します。

The value of this MIB object MUST NOT persist across MTA reboots."

このMIBオブジェクトの値はMTAのリブートを渡って持続してはいけません。」

    DEFVAL { rpAsETS }
    ::= {pktcSigDevObjects 27 }
        

pktcSigDevVmwiAfterDTAS OBJECT-TYPE SYNTAX Unsigned32 (0|45..500) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of the Dual Tone Alert Signal (DT-AS) and the start of the transmission of the FSK or DTMF containing the VMWI information.

pktcSigDevVmwiAfterDTAS OBJECT-TYPE構文Unsigned32(0 | 45..500)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはデュアルトーン警報信号(DT-AS)の終了と開始の間の遅延を指定しますVMWI情報を含むFSKまたはDTMFの送信。

          This object is only used when pktcSigDevVmwiMode is
          set to a value of 'dtAsETS' or 'lrAsETS'.
        

The following table defines the default values for this MIB object, depending on the signal type (pktcSigDevVmwiMode), and MUST be followed:

次の表は、信号タイプ(pktcSigDevVmwiMode)に応じて、このMIBオブジェクトのデフォルト値を定義し、続かなければなりません。

Value of pktcSigDevVmwiMode Default value

pktcSigDevVmwiModeデフォルト値の値

dtAsETS 50 ms rpAsETS any value (not used) lrAsETS 50 ms lrETS any value (not used)

(使用しない)任意の値が50ミリ秒のlrETSを(使用しない)任意の値をlrAsETS dtAsETS 50ミリ秒rpAsETS

An attempt to set this object while the value of pktcSigDevVmwiMode is not 'dtAsETS' or 'lrAsETS' will result in an 'inconsistentValue' error.

pktcSigDevVmwiModeの値が「dtAsETS」または「lrAsETS」でないときにこのオブジェクトを設定する試みはから「inconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 50 }
    ::= {pktcSigDevObjects 28 }
        

pktcSigDevVmwiAfterRPAS OBJECT-TYPE SYNTAX Unsigned32 (0|500..800)

pktcSigDevVmwiAfterRPASのOBJECT-TYPE構文Unsigned32(0 | 500..800)

    UNITS        "Milliseconds"
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        " This object specifies the delay between the end of the
          Ring Pulse Alert Signal (RP-AS) and the start of the
          transmission of the FSK or DTMF containing the VMWI
          information.
        
          This object is only used when pktcSigDevVmwiMode is
          set to a value of 'rpAsETS'.
        

The following table defines the default values for this MIB object, depending on the signal type (pktcSigDevVmwiMode), and MUST be followed:

次の表は、信号タイプ(pktcSigDevVmwiMode)に応じて、このMIBオブジェクトのデフォルト値を定義し、続かなければなりません。

Value of pktcSigDevVmwiMode Default value

pktcSigDevVmwiModeデフォルト値の値

dtAsETS any value (not used) rpAsETS 650 ms lrAsETS any value (not used) lrETS any value (not used)

(使用しない)任意の値が650ミリ秒lrAsETSを(使用しない)任意の値をrpAsETS dtAsETS(使用しない)任意の値をlrETS

An attempt to set this object while the value of pktcSigDevVmwiMode is not 'rpAsETS' will result in an 'inconsistentValue' error.

pktcSigDevVmwiModeの値がない間、このオブジェクトを設定する試みは、「rpAsETSは」「はinconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 650 }
    ::= {pktcSigDevObjects 29 }
        

pktcSigDevVmwiDTASAfterLR OBJECT-TYPE SYNTAX Unsigned32 (0|50..655) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the delay between the end of the Line Reversal and the start of the Dual Tone Alert Signal (DT-AS) for VMWI information. This object is only used when pktcSigDevVmwiMode is set to a value of 'lrAsETS'.

pktcSigDevVmwiDTASAfterLRのOBJECT-TYPE構文Unsigned32(0 | 50..655)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトはライン反転の終了およびデュアルトーン警報信号(の開始間の遅延を指定しますpktcSigDevVmwiMode「はlrAsETS」の値に設定されている場合VMWI情報のDT-AS)。この目的にのみ使用されます。

          The following table defines the default values
          for this MIB object, depending on the signal type
         (pktcSigDevVmwiMode), and MUST be followed:
        

Value of pktcSigDevVmwiMode Default value

pktcSigDevVmwiModeデフォルト値の値

dtAsETS any value (not used) rpAsETS any value (not used) lrAsETS 250 ms lrETS any value (not used)

いずれかの値が(使用しない)任意の値を(未使用)250ミリ秒lrETS任意の値をlrAsETS rpAsETS dtAsETS(未使用)

An attempt to set this object while the value of pktcSigDevVmwiMode is not 'lrAsETS' will result in an 'inconsistentValue' error.

pktcSigDevVmwiModeの値がない間、このオブジェクトを設定する試みは、「lrAsETSは」「はinconsistentValue」エラーになります。

          The value of this MIB object MUST NOT persist across MTA
          reboots."
    REFERENCE
        "ETSI-EN-300-659-1 Specification"
    DEFVAL { 250 }
    ::= {pktcSigDevObjects 30 }
        
pktcSigDevRingCadenceTable    OBJECT-TYPE
    SYNTAX       SEQUENCE OF PktcSigDevRingCadenceEntry
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        "Cadence rings are defined by the telco governing
         body for each country.  The MTA must be able to support
         various ranges of cadence patterns and cadence periods.
         The MTA will be able to support country-specific
         provisioning of the cadence and idle period.  Each
         cadence pattern will be assigned a unique value ranging
         from 0-127 (inclusive) corresponding to the value of x,
         where x is the value sent in the cadence ringing (cr)
         signal cr(x), requested per the appropriate NCS
         message, and defined in the E package.  The MTA will derive
         the cadence periods from the ring cadence table entry, as
         provisioned by the customer.  The MTA is allowed to provide
         appropriate default values for each of the ring cadences.
         This table only needs to be supported when the MTA
         implements the E package."
    REFERENCE
        "ETSI-TS-101-909-4 Specification"
    ::= { pktcSigDevObjects 31 }
        

pktcSigDevRingCadenceEntry OBJECT-TYPE SYNTAX PktcSigDevRingCadenceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

pktcSigDevRingCadenceEntryのOBJECT-TYPE SYNTAX PktcSigDevRingCadenceEntry MAX-ACCESSステータス現在の説明

        " Each entry in this row corresponds to a ring cadence
          that is being supported by the device.  The conceptual
          rows MUST NOT persist across MTA reboots."
    INDEX { pktcSigDevRingCadenceIndex }
    ::= { pktcSigDevRingCadenceTable 1 }
        
PktcSigDevRingCadenceEntry ::= SEQUENCE {
        pktcSigDevRingCadenceIndex       Unsigned32,
        pktcSigDevRingCadence            PktcRingCadence
    }
        
pktcSigDevRingCadenceIndex    OBJECT-TYPE
    SYNTAX       Unsigned32 (0..127)
    MAX-ACCESS   not-accessible
    STATUS       current
    DESCRIPTION
        " A unique value ranging from 0 to 127 that corresponds to the
          value sent by the LE based on country-specific cadences,
          one row per cadence cycle.  In any given system
          implementation for a particular country, it is anticipated
          that a small number of ring cadences will be in use.  Thus,
          this table most likely will not be populated to its full
          size."
    ::= { pktcSigDevRingCadenceEntry 1 }
        
pktcSigDevRingCadence    OBJECT-TYPE
    SYNTAX       PktcRingCadence
    MAX-ACCESS   read-write
    STATUS       current
    DESCRIPTION
        "This is the Ring Cadence."
    ::= { pktcSigDevRingCadenceEntry 2 }
        

pktcSigDevToneTable OBJECT-TYPE SYNTAX SEQUENCE OF PktcSigDevToneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The Tone Table defines the composition of tones and various tone operations.

PktcSigDevToneEntry MAX-ACCESSステータス現在の説明のpktcSigDevToneTable OBJECT-TYPE構文配列は「トーンテーブルトーンや各種トーン動作の組成を規定します。

          The definition of the tones callWaiting1 through
          callWaiting4 in this table MUST only contain the
          audible tone itself; the delay between tones or the value
          of the tone repeat count are not applicable for the call
          waiting tones.
        

The delay between tones or the repeat count is controlled by the objects pktcSigEndPntConfigCallWaitingDelay and pktcSigEndPntConfigCallWaitingMaxRep. If the pktcSigDevToneType is set to either of the values callWaiting1, callWaiting2, callWaiting3, or callWaiting4, then the value of the pktcSigDevToneWholeToneRepeatCount object indicates that the particular frequency group is applicable, as a repeatable part of the tone, based on the value of the MIB object pktcSigDevToneWholeToneRepeatCount.

トーンまたは繰り返し回数との間の遅延は、オブジェクトpktcSigEndPntConfigCallWaitingDelayとpktcSigEndPntConfigCallWaitingMaxRepによって制御されます。 pktcSigDevToneTypeが値callWaiting1、callWaiting2、callWaiting3、又はcallWaiting4のいずれかに設定されている場合、pktcSigDevToneWholeToneRepeatCountオブジェクトの値は、MIBの値に基づいて、トーンの再現一部として、特定の周波数グループが適用可能であることを示しpktcSigDevToneWholeToneRepeatCountオブジェクト。

The MTA MUST make sure that, after the provisioning cycle, the table is fully populated (i.e., for each possible index, an entry MUST be defined) using reasonable defaults for each row that was not defined by the provisioning information delivered via MTA Configuration.

MTAは、プロビジョニング・サイクルの後、テーブルが完全にMTA設定を介して送達プロビジョニング情報によって定義されていない行ごとに合理的なデフォルト値を使用して(すなわち、それぞれの可能なインデックスに、エントリが定義されなければならない)に移入することを確認しなければなりません。

The frequency composition of each tone is defined by the pktcSigDevMultiFreqToneTable. For each tone type defined in pktcSigDevToneTable, the MTA MUST populate at least one entry in the pktcSigDevMultiFreqToneTable.

各トーンの周波数組成物はpktcSigDevMultiFreqToneTableによって定義されます。 pktcSigDevToneTableで定義された各トーン型ため、MTAはpktcSigDevMultiFreqToneTable内の少なくとも1つのエントリを投入しなければなりません。

For each particular value of pktcSigDevToneType, the pktcSigDevToneTable table can define non-repeating and repeating groups of the frequencies defined by the pktcSigDevMultiFreqToneTable, such that each group is represented by the set of the consecutive rows (frequency group) in the pktcSigDevMultiFreqToneTable.

pktcSigDevToneTypeのそれぞれの特定の値に対して、pktcSigDevToneTableテーブルは、各グループがpktcSigDevMultiFreqToneTableにおける連続する行(周波数群)の集合によって表されるように、pktcSigDevMultiFreqToneTableによって定義された周波数の非繰り返しと繰り返しグループを定義することができます。

          Objects in this table do not persist across MTA reboots.
          For tones with multiple frequencies refer to the MIB table
          pktcSigDevMultiFreqToneTable."
    REFERENCE
        "PacketCable NCS Specification, ETSI-TS-101-909-4
         Specification."
    ::= { pktcSigDevObjects 32 }
        

pktcSigDevToneEntry OBJECT-TYPE SYNTAX PktcSigDevToneEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The different tone types that can be provisioned based on country-specific needs.

pktcSigDevToneEntryのOBJECT-TYPE SYNTAX PktcSigDevToneEntry MAX-ACCESSステータス現在の説明は「国固有のニーズに基づいてプロビジョニングすることができます異なるトーンタイプ。

          Each entry contains the tone generation parameters for
          a specific frequency group of the specific Tone Type.
        
          The different parameters can be provisioned via MTA
          configuration based on country specific needs.
          An MTA MUST populate all entries of this table for each
          tone type."
    INDEX { pktcSigDevToneType, pktcSigDevToneFreqGroup }
    ::= { pktcSigDevToneTable 1 }
        
PktcSigDevToneEntry ::= SEQUENCE {
    pktcSigDevToneType                      INTEGER,
    pktcSigDevToneFreqGroup                 Unsigned32,
    pktcSigDevToneFreqCounter               Unsigned32,
    pktcSigDevToneWholeToneRepeatCount      Unsigned32,
    pktcSigDevToneSteady                    TruthValue
    }
        

pktcSigDevToneType OBJECT-TYPE SYNTAX INTEGER { busy(1), confirmation(2), dial(3), messageWaiting(4), offHookWarning(5), ringBack(6), reOrder(7), stutterdial(8), callWaiting1(9), callWaiting2(10), callWaiting3(11), callWaiting4(12), alertingSignal(13), specialDial(14), specialInfo(15), release(16), congestion(17), userDefined1(18), userDefined2(19), userDefined3(20), userDefined4(21) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value that will correspond to the different tone types. These tones can be provisioned based on country-specific needs. This object defines the type of tone being accessed.

pktcSigDevToneTypeのOBJECT-TYPE SYNTAX INTEGER {(1)ビジー、確認(2)、(3)ダイヤル、messageWaiting(4)、offHookWarning(5)、リングバック(6)、リオーダー(7)、(8)stutterdial、callWaiting1(9 )、callWaiting2(10)、callWaiting3(11)、callWaiting4(12)、alertingSignal(13)、specialDial(14)、specialInfo(15)、リリース(16)、輻輳(17)、userDefined1(18)、userDefined2(19 )、userDefined3(20)、userDefined4(21)} MAX-ACCESSステータス現在の説明は「異なるトーンタイプに対応する一意の値。これらのトーンは、国固有のニーズに基づいてプロビジョニングすることができる。このオブジェクトは、定義され音の種類は、アクセスされています。

         The alertingSignal, specialDial, specialInfo, release, congestion, userDefined1, userDefined2, userDefined3,
         and userDefined4 tone types are used in
         the E line package."
    ::= { pktcSigDevToneEntry 1 }
        
pktcSigDevToneFreqGroup  OBJECT-TYPE
       SYNTAX       Unsigned32(1..4)
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
           "This MIB object represents the Tone Sequence reference
           of a multi-sequence tone."
       ::={ pktcSigDevToneEntry 2}
        

pktcSigDevToneFreqCounter OBJECT-TYPE SYNTAX Unsigned32(1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object represents the number of consecutive multi-frequency tones for the particular tone type in the multi-frequency table (pktcSigDevMultiFreqToneTable).

pktcSigDevToneFreqCounterのOBJECT-TYPE構文Unsigned32(1..8)MAX-ACCESS read-onlyステータス現在の説明は「このMIBオブジェクトは、マルチ周波数テーブル(pktcSigDevMultiFreqToneTable)における特定のトーンタイプの連続マルチ周波数トーンの数を表します。

           Such a sequence of the consecutive multi-frequency tones
           forms the tone group for the particular tone type in the
           pktcSigDevToneTable."
       ::={ pktcSigDevToneEntry 3}
        
pktcSigDevToneWholeToneRepeatCount      OBJECT-TYPE
    SYNTAX       Unsigned32 (0..5000)
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "This is the repeat count, which signifies how many times
         to repeat the entire on-off cadence sequence.  Setting this
         object may result in a cadence duration longer or shorter
         than the overall signal duration specified by the time out
         (TO) object for a particular signal.  If the repeat count
         results in a longer tone duration than the signal duration
         specified by the TO, the tone duration defined by the
         TO object for a particular signal always represents
         the overall signal duration for a tone.  In this case, the
         tone duration repeat count will not be fully exercised, and
         the desired tone duration will be truncated per the TO
         setting.  If the repeat count results in a shorter tone
         duration than the signal duration specified by the TO, the
         tone duration defined by the repeat count takes precedence
         over the TO and will end the signal event.  In this case, the TO represents a time not to be exceeded for the signal.
         It is recommended to ensure proper telephony signaling so that
         the TO duration setting should always be longer than the
         desired repeat count-time duration."
    ::={ pktcSigDevToneEntry 4 }
        

pktcSigDevToneSteady OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object represents the steady tone status. A value of 'true(1)' indicates that the steady tone is applied, and a value of 'false(2)' indicates otherwise. Devices must play out the on-off cadence sequence for the number of times indicated by the MIB object 'pktcSigDevToneWholeToneRepeatCount' prior to applying the last tone steadily, indefinitely. If the MIB table 'pktcSigDevToneTable' contains multiple rows with this Object set to a value of 'true(1)', the steady tone is applied to the last repeating frequency group of the tone.

このMIBオブジェクトが定常トーン状態を表す。の値pktcSigDevToneSteady OBJECT-TYPEの構文のTruthValue MAX-ACCESS read-only説明は、」 『真(1)』定常トーンが適用されていることを示し、偽(2」の値「)そうでないことを示します。デバイスは、MIBオブジェクトによって示される回数のためのオン・オフリズムシーケンスを再生しなければならない 『』無期限、前に着実に最後のトーンを適用する。MIBテーブルが 『pktcSigDevToneWholeToneRepeatCount pktcSigDevToneTableは』これで複数の行が含まれています「真(1)」の値に設定する目的は、安定したトーンはトーンの最後の繰り返し周波数グループに適用されます。

         Setting this MIB object may result in a tone duration that is
         longer or shorter than the overall signal duration
         specified by the time out (TO) MIB object for a particular
         signal.  If the repeat count results in a longer tone
         duration than the signal duration specified by the TO, the
         tone duration defined by the TO object for a particular
         signal always represents the overall signal duration for a
         tone.  In this case, the tone duration repeat count will
         not be fully exercised, and the desired tone duration will
         be truncated per the TO setting.  If the repeat count
         results in a shorter tone duration than the signal duration
         specified by the TO, the tone duration defined by the
         repeat count takes precedence over the TO and will end the
         signal event.  In this case, the TO represents a time not to
         be exceeded for the signal.
        
         It is recommended to ensure proper telephony signaling that
         The TO duration setting should always be longer than the
         desired repeat count-time duration, plus the desired maximum
         steady tone period."
    ::={ pktcSigDevToneEntry 5 }
        

pktcSigDevMultiFreqToneTable OBJECT-TYPE SYNTAX SEQUENCE OF PktcSigDevMultiFreqToneEntry MAX-ACCESS not-accessible STATUS current

PktcSigDevMultiFreqToneEntry MAX-ACCESSステータス電流のpktcSigDevMultiFreqToneTable OBJECT-TYPE構文配列

       DESCRIPTION
           " This MIB table defines the characteristics of tones
             with multiple frequencies.  The constraints imposed
             on the tones by the MIB table pktcSigDevToneTable
             need to be considered for MIB objects in this table
             as well.
        
             The MTA MUST populate the corresponding row(s)
             of the pktcSigDevMultiFreqToneTable for each tone
             defined in the pktcSigDevToneTable.
        
             The contents of the table may be provisioned via
             MTA configuration."
       REFERENCE
           "PacketCable NCS Specification, ETSI-TS-101-909-4
            Specification."
       ::= { pktcSigDevObjects 33 }
        
   pktcSigDevMultiFreqToneEntry    OBJECT-TYPE
       SYNTAX       PktcSigDevMultiFreqToneEntry
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
           " The different tone types with multiple frequencies
             that can be provisioned based on country-specific
             needs."
       INDEX {pktcSigDevToneType, pktcSigDevToneNumber}
       ::= { pktcSigDevMultiFreqToneTable 1 }
        
   PktcSigDevMultiFreqToneEntry ::= SEQUENCE {
         pktcSigDevToneNumber                    Unsigned32,
         pktcSigDevToneFirstFreqValue            Unsigned32,
         pktcSigDevToneSecondFreqValue           Unsigned32,
         pktcSigDevToneThirdFreqValue            Unsigned32,
         pktcSigDevToneFourthFreqValue           Unsigned32,
         pktcSigDevToneFreqMode                  INTEGER,
         pktcSigDevToneFreqAmpModePrtg           Unsigned32,
         pktcSigDevToneDbLevel                   TenthdBm,
         pktcSigDevToneFreqOnDuration            Unsigned32,
         pktcSigDevToneFreqOffDuration           Unsigned32,
         pktcSigDevToneFreqRepeatCount           Unsigned32
   }
        

pktcSigDevToneNumber OBJECT-TYPE SYNTAX Unsigned32(1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION

pktcSigDevToneNumberのOBJECT-TYPE構文Unsigned32(1..8)MAX-ACCESSステータス現在の説明

          "This MIB object represents the frequency reference
           of a multi-frequency tone."
       ::={ pktcSigDevMultiFreqToneEntry 1}
        
   pktcSigDevToneFirstFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the first
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 2}
        
   pktcSigDevToneSecondFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the second
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 3}
        
   pktcSigDevToneThirdFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the third
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 4}
        
   pktcSigDevToneFourthFreqValue    OBJECT-TYPE
       SYNTAX       Unsigned32(0..4000)
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
         "This MIB object represents the value of the fourth
          frequency of a tone type.  A value of zero implies
          absence of the referenced frequency."
       ::={ pktcSigDevMultiFreqToneEntry 5}
        

pktcSigDevToneFreqMode OBJECT-TYPE SYNTAX INTEGER { firstModulatedBySecond(1), summation(2)

pktcSigDevToneFreqModeのOBJECT-TYPE SYNTAX INTEGER {firstModulatedBySecond(1)、加算(2)

                    }
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
       "This MIB object provides directive on the
        modulation or summation of the frequencies
        involved in the tone.
        

It is to be noted that while summation can be done without any constraint on the number of frequencies, the modulation (amplitude) holds good only when there are two frequencies (first and second).

これは、総和が周波数の数の任意の制約なしに行うことができるが、変調(振幅)は、2つの周波数(第1及び第2)がある場合にのみ成り立つことに留意すべきです。

Thus: - If the mode is set to a value of 'firstModulatedBySecond(1)', the first frequency MUST be modulated by the second, and the remaining frequencies (third and fourth) ignored. The percentage of amplitude modulation to be applied is defined by the MIB object pktcSigDevToneFreqAmpModePrtg.

したがって: - モードが「firstModulatedBySecond(1)」の値に設定されている場合、第一の周波数は第によって変調されなければならない、そして、残りの周波数(第三及び第四)は無視します。適用される振幅変調のパーセンテージは、MIBオブジェクトpktcSigDevToneFreqAmpModePrtgによって定義されます。

          - If the mode is set to a value of
            'summation(2)', all the frequencies MUST be
            summed without any modulation.
       "
       ::={ pktcSigDevMultiFreqToneEntry 6}
        

pktcSigDevToneFreqAmpModePrtg OBJECT-TYPE SYNTAX Unsigned32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object represents the percentage of amplitude modulation applied to the second frequency when the MIB object pktcSigDevToneFreqMode is set to a value of 'firstModulatedBySecond (1)'.

pktcSigDevToneFreqAmpModePrtgのOBJECT-TYPEの構文Unsigned32 MIBオブジェクトpktcSigDevToneFreqMode「はfirstModulatedBySecond(の値に設定されているときに現在の説明は「このMIBオブジェクトが第二の周波数に適用される振幅変調の割合を表す(0..100)MAX-ACCESS read-onlyステータス1)」。

           If the MIB object pktcSigDevToneFreqMode is set to
           value of 'summation (2)', then this MIB object MUST be
           ignored."
       ::={ pktcSigDevMultiFreqToneEntry 7}
        

pktcSigDevToneDbLevel OBJECT-TYPE SYNTAX TenthdBm (-250..-110) UNITS "1/10 of a dBm" MAX-ACCESS read-only

pktcSigDevToneDbLevel OBJECT-TYPE構文TenthdBm(-250 ..- 110)UNITS "dBm単位の1/10" MAX-ACCESS読み取り専用

      STATUS       current
      DESCRIPTION
          "This MIB object contains the decibel level for each
           analog signal (tone) that is locally generated
           (versus in-band supervisory tones) and sourced to
           the a-b terminals (TE connection point).  Each tone
           in itself may consist of multiple frequencies, as
           defined by the MIB table pktcSigDevMultiFreqToneTable.
        
           This MIB object reflects the desired level at
           the Telco (POTS) a-b (T/R) terminals, including the
           effect of any MTA receiver gain (loss).  This is required
           so that locally generated tones are consistent with
           remotely generated in-band tones at the a-b terminals,
           consistent with user expectations.
        

This MIB object must be set for each tone. When tones are formed by combining multi-frequencies, the level of each frequency shall be set so as to result in the tone level specified in this object at the a-b (T/R) terminals.

このMIBオブジェクトは、トーンごとに設定する必要があります。トーンマルチ周波数を組み合わせることによって形成されている場合、A-B(T / R)端子に、このオブジェクトに指定された階調レベルが得られるように、各周波数のレベルが設定されなければなりません。

           The wide range of levels for this Object is required
           to provide signal-generator levels across the wide
           range of gains (losses) -- but does not imply the entire
           range is to be achievable given the range of gains (losses)
           in the MTA."
    DEFVAL { -120 }
    ::={ pktcSigDevMultiFreqToneEntry 8}
        
   pktcSigDevToneFreqOnDuration OBJECT-TYPE
       SYNTAX       Unsigned32(0..5000)
       UNITS        "milliseconds"
       MAX-ACCESS   read-only
       STATUS       current
       DESCRIPTION
          "This MIB object represents the duration for which the
           frequency reference corresponding to the tone type
           is turned on."
       ::={ pktcSigDevMultiFreqToneEntry 9}
        

pktcSigDevToneFreqOffDuration OBJECT-TYPE SYNTAX Unsigned32(0..5000) UNITS "milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object represents the duration for which the

pktcSigDevToneFreqOffDurationのOBJECT-TYPE構文Unsigned32(0..5000)UNITS "ミリ秒" MAX-ACCESS read-only説明「このMIBオブジェクトはのための期間を表します

           frequency reference corresponding to the tone type
           is turned off."
       ::={ pktcSigDevMultiFreqToneEntry 10}
        

pktcSigDevToneFreqRepeatCount OBJECT-TYPE SYNTAX Unsigned32(0..5000) MAX-ACCESS read-only STATUS current DESCRIPTION "This MIB object indicates the number of times to repeat the cadence cycle represented by the on/off durations (refer to the MIB objects pktcSigDevToneFreqOnDuration and pktcSigDevToneFreqOffDuration).

pktcSigDevToneFreqRepeatCountのOBJECT-TYPE構文Unsigned32(0..5000)MAX-ACCESS read-onlyステータス現在の説明は「このMIBオブジェクトは、オン/オフ期間が(MIBがpktcSigDevToneFreqOnDurationオブジェクトを参照することによって示されるケーデンスサイクルを繰り返す回数を示し、 pktcSigDevToneFreqOffDuration)。

       Setting this object may result in a tone duration that is
       longer or shorter than the overall signal duration
       specified by the time out (TO) object for the
       corresponding tone type.  If the value of this MIB
       Object indicates a longer duration than that
       specified by the TO, the latter overrules the former,
       and the desired tone duration will be truncated according
       to the TO.
        
       However, if the repeat count results in a shorter
       tone duration than the signal duration specified by
       the TO, the tone duration defined by the repeat count
       takes precedence over the TO and will end the signal
       event.  In this case, the TO represents a time not to
       be exceeded for the signal.  It is recommended, to
       ensure proper telephony signaling, that the TO
       duration setting should always be longer than the
       desired repeat count-time duration.  A value of zero
       means the tone sequence is to be played once but not
       repeated."
       ::={ pktcSigDevMultiFreqToneEntry 11}
        

pktcSigDevCidDelayAfterLR OBJECT-TYPE SYNTAX Unsigned32 (300..800) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the delay between the end of the Line Reversal and the start of the FSK or DTMF signal. This MIB object is used only when pktcSigDevCidMode is set to a value of 'lrETS'. This timing has a range of 300 to 800 ms.

pktcSigDevCidDelayAfterLRのOBJECT-TYPE構文Unsigned32(300..800)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、ライン反転の端とFSK又はDTMF信号の開始との間の遅延を指定する。このMIBオブジェクトがpktcSigDevCidModeが「lrETS」の値に設定されている場合にのみ使用される。このタイミングは、300〜800ミリ秒の範囲を有します。

            The following table defines the default values
            for this MIB object, depending on the signal type
           (pktcSigDevCidMode), and MUST be followed:
        

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS any value (not used) rpAsETS any value (not used) lrAsETS any value (not used) lrETS 400

duringringingETS任意の値(未使用)(未使用)の任意の値をdtAsETS(使用しない)任意の値をrpAsETS(使用しない)任意の値をlrAsETS lrETS 400

An attempt to set this object while the value of pktcSigDevCidMode is not set to a value of 'lrETS' will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値が「lrETS」の値に設定されていない一方で、このオブジェクトを設定する試みはから「inconsistentValue」エラーになります。

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       DEFVAL { 400 }
       ::= {pktcSigDevObjects 34 }
        

pktcSigDevCidDtmfStartCode OBJECT-TYPE SYNTAX DtmfCode MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies optional start codes used when the MIB object pktcSigDevCidSigProtocol is set to a value of 'dtmf(2)'.

pktcSigDevCidDtmfStartCode OBJECT-TYPE構文DtmfCode MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、MIBオブジェクトpktcSigDevCidSigProtocol 『はDTMF(2)』の値に設定されている場合に使用されるオプションのスタートコードを識別する。

            Different countries define different caller id signaling
            codes to support caller identification.  When Dual-Tone
            Multi-Frequency (DTMF) is used, the caller id digits are
            preceded by a 'start code' digit, followed by the digit
            transmission sequence <S1>...<Sn> (where Sx represents
            the digits 0-9), and terminated by the 'end code' digit.
        

For example, <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>. The start code for calling number delivery may be DTMF 'A' or 'D'. The start code for redirecting a number may be DTMF 'D'. The DTMF code 'B' may be sent by the network as a start code for the transfer of information values, through which special events can be indicated to the user. In some countries, the '*' or '#' may be used instead of 'A', 'B', 'C', or 'D'.

例えば、<A> <S1> ... <Snの> <D> <S1> ... <Snの> <B> <S1> ... <Snの> <C>。数配信を呼び出すためのスタートコードはDTMF「A」または「D」であってもよいです。番号をリダイレクトするためのスタートコードはDTMF「D」であってもよいです。 DTMFコード「B」は、特別なイベントをユーザに示すことができ、それを通して情報値の転送のためのスタートコードとしてネットワークによって送信されても​​よいです。いくつかの国では、「*」または「#」が代わりに「A」、「B」、「C」または「D」を用いてもよいです。

            The value of this MIB object MUST NOT persist across MTA reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeA}
   ::= { pktcSigDevObjects 35 }
        

pktcSigDevCidDtmfEndCode OBJECT-TYPE SYNTAX DtmfCode MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies optional end codes used when the pktcSigDevCidSigProtocol is set to a value of 'dtmf(2)'.

pktcSigDevCidDtmfEndCode OBJECT-TYPE構文DtmfCode MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトpktcSigDevCidSigProtocol 『はDTMF(2)』の値に設定されている場合に使用されるオプションのエンドコードを識別する。

            Different countries define different caller id signaling
            protocols to support caller identification.  When
            Dual-Tone Multi-Frequency (DTMF) is used, the caller id
            digits are preceded by a 'start code' digit, followed by
            the digit transmission sequence <S1>...<Sn> (where Sx
            represents the digits 0-9), and terminated by the 'end
            code' digit.
        

For example, <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.

例えば、<A> <S1> ... <Snの> <D> <S1> ... <Snの> <B> <S1> ... <Snの> <C>。

The DTMF code 'C' may be sent by the network as an end code for the transfer of information values, through which special events can be indicated to the user. In some countries, the '*' or '#' may be used instead of 'A', 'B', 'C', or 'D'.

DTMFコード「C」は、特別なイベントをユーザに示すことができ、それを通して情報値の転送のためのエンドコードとしてネットワークによって送信されても​​よいです。いくつかの国では、「*」または「#」が代わりに「A」、「B」、「C」または「D」を用いてもよいです。

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeC}
   ::= { pktcSigDevObjects 36 }
        

pktcSigDevVmwiSigProtocol OBJECT-TYPE SYNTAX PktcSubscriberSideSigProtocol MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies the subscriber line protocol used for signaling the information on Visual Message Waiting Indicator (VMWI). Different countries define different VMWI signaling protocols to support VMWI service.

pktcSigDevVmwiSigProtocolのOBJECT-TYPE SYNTAX PktcSubscriberSideSigProtocol MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、Visualメッセージ待機インジケータ(VMWI)に関する情報をシグナリングに使用加入者線プロトコルを識別します。さまざまな国は、VMWIサービスをサポートするために、異なるVMWIシグナリングプロトコルを定義します。

            Frequency shift keying (FSK) is most commonly used.
            DTMF is an alternative.
        
            The value of this MIB object MUST NOT persist across MTA
            reboots."
        DEFVAL { fsk }
   ::= { pktcSigDevObjects 37 }
        

pktcSigDevVmwiDelayAfterLR OBJECT-TYPE SYNTAX Unsigned32 (0|300..800) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the delay between the end of the Line Reversal and the start of the FSK or DTMF signal. This object is only used when pktcSigDevVmwiMode is set to a value of 'lrETS'. This timing has a range of 300 to 800 ms.

pktcSigDevVmwiDelayAfterLRのOBJECT-TYPE構文Unsigned32(0 | 300..800)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクトは、ライン反転の終わりとFSKかDTMF信号の開始間の遅延を指定します。 pktcSigDevVmwiMode「はlrETS」の値に設定されている場合、このオブジェクトにのみ使用される。このタイミングは、300〜800ミリ秒の範囲を有します。

            The following table defines the default values
            for this MIB object, depending on the signal type
           (pktcSigDevVmwiMode), and MUST be followed:
        

Value of pktcSigDevVmwiMode Default value

pktcSigDevVmwiModeデフォルト値の値

duringringingETS any value (not used) dtAsETS any value (not used) rpAsETS any value (not used) lrAsETS any value (not used) lrETS 400

duringringingETS任意の値(未使用)(未使用)の任意の値をdtAsETS(使用しない)任意の値をrpAsETS(使用しない)任意の値をlrAsETS lrETS 400

An attempt to set this object while the value of pktcSigDevVmwiMode is not 'lrETS' will result in an 'inconsistentValue' error.

pktcSigDevVmwiModeの値がない間、このオブジェクトを設定する試みは、「lrETSは」「はinconsistentValue」エラーになります。

The value of this MIB object MUST NOT persist across MTA reboots."

このMIBオブジェクトの値はMTAのリブートを渡って持続してはいけません。」

       DEFVAL {400}
           ::= {pktcSigDevObjects 38 }
        

pktcSigDevVmwiDtmfStartCode OBJECT-TYPE SYNTAX DtmfCode MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies optional start codes used when

pktcSigDevVmwiDtmfStartCode OBJECT-TYPE構文DtmfCode MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクト使用される任意のスタートコードを識別する

            the pktcSigDevVmwiSigProtocol is set to a value of
            'dtmf(2)'.  Different countries define different On Hook
            Data Transmission Protocol signaling codes to support
            VMWI.
        

When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI digits are preceded by a 'start code' digit, followed by the digit transmission sequence <S1>...<Sn> (where Sx represents the digits 0-9), and terminated by the 'end code' digit.

デュアルトーン多重周波数(DTMF)を使用する場合、VMWI数字は数字送信シーケンスが続く、「スタートコード」の数字が先行する<S1> ... <のSn>(Sxが数字を表し0-9 )、および「末端コード」ケタによって終了。

For example, <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.

例えば、<A> <S1> ... <Snの> <D> <S1> ... <Snの> <B> <S1> ... <Snの> <C>。

The start code for redirecting VMWI may be DTMF 'D' The DTMF code 'B' may be sent by the network as a start code for the transfer of information values, through which special events can be indicated to the user. In some countries, the '*' or '#' may be used instead of 'A', 'B', 'C', or 'D'.

VMWIがDTMF「D」DTMFコード「B」であってもよいリダイレクトするためのスタートコードは、特別なイベントをユーザに示すことができ、それを通して情報値の転送のためのスタートコードとしてネットワークによって送信されても​​よいです。いくつかの国では、「*」または「#」が代わりに「A」、「B」、「C」または「D」を用いてもよいです。

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeA}
   ::= { pktcSigDevObjects 39 }
        

pktcSigDevVmwiDtmfEndCode OBJECT-TYPE SYNTAX DtmfCode MAX-ACCESS read-write STATUS current DESCRIPTION "This object identifies an optional end code used when the pktcSigDevVmwiSigProtocol is set to a value of 'dtmf(2)'. Different countries define different on-hook Data Transmission Protocol signaling codes to support VMWI.

pktcSigDevVmwiDtmfEndCode OBJECT-TYPE構文DtmfCode MAX-ACCESS読み取りと書き込みステータス現在の説明pktcSigDevVmwiSigProtocol 『はDTMF(2)』の値に設定されている場合、「このオブジェクトは使用されるオプションの終了コードを識別する。異なる国は異なるオンフックデータ伝送プロトコルを定義しますVMWIをサポートするためのシグナリング符号。

            When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI
            digits are preceded by a 'start code' digit, followed
            by the digit transmission sequence <S1>...<Sn> (where
            Sx represents the digits 0-9), and terminated by the 'end
            code' digit.
        

For example, <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.

例えば、<A> <S1> ... <Snの> <D> <S1> ... <Snの> <B> <S1> ... <Snの> <C>。

The DTMF code 'C' may be sent by the network as an end code for the transfer of information values, through which special events can be indicated to the user. In some countries, the '*' or '#' may be used instead of 'A', 'B', 'C', or 'D'.

DTMFコード「C」は、特別なイベントをユーザに示すことができ、それを通して情報値の転送のためのエンドコードとしてネットワークによって送信されても​​よいです。いくつかの国では、「*」または「#」が代わりに「A」、「B」、「C」または「D」を用いてもよいです。

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
            "ETSI-EN-300-659-1 specification"
       DEFVAL {dtmfcodeC}
   ::= { pktcSigDevObjects 40 }
        

pktcSigDevrpAsDtsDuration OBJECT-TYPE SYNTAX Unsigned32 (0|200..500) UNITS "Milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION " This object specifies the duration of the rpASDTS ring pulse prior to the start of the transmission of the FSK or DTMF containing the caller id information. It is only used when pktcSigDevCidMode is set to a value of 'rpAsETS'.

pktcSigDevrpAsDtsDurationのOBJECT-TYPEの構文Unsigned32(0 | 200..500)UNITS「ミリ秒」MAX-ACCESS読み取りと書き込みステータス現在の説明は「このオブジェクト前FSKの送信の開始又はDTMFにrpASDTSリングパルスの持続時間を指定します発信者ID情報を含む。pktcSigDevCidMode「はrpAsETS」の値に設定されているときにのみ使用されます。

             The following table defines the default values
             for this MIB object, depending on the signal type
            (pktcSigDevCidMode), and MUST be followed:
        

Value of pktcSigDevCidMode Default value

pktcSigDevCidModeデフォルト値の値

duringringingETS any value (not used) dtAsETS any value (not used) rpAsETS 250 lrAsETS any value (not used) lrETS any value (not used)

いずれかの値が(使用しない)任意の値を(未使用)250 lrAsETS(使用しない)任意の値をrpAsETS任意の値をlrETS dtAsETS duringringingETS(未使用)

An attempt to set this object while the value of pktcSigDevCidMode is not 'rpAsETS' will result in an 'inconsistentValue' error.

pktcSigDevCidModeの値がない間、このオブジェクトを設定する試みは、「rpAsETSは」「はinconsistentValue」エラーになります。

            The value of this MIB object MUST NOT persist across MTA
            reboots."
       REFERENCE
           "ETSI-EN-300-659-1 Specification and Belgacom
            BGC_D_48_9811_30_09_EDOC version 3.3"
       DEFVAL { 250 }
       ::= {pktcSigDevObjects 41 }
        

-- -- The Endpoint Config Table is used to define attributes that -- are specific to connection EndPoints. --

- - 接続エンドポイントに固有の - エンドポイント構成テーブルは、属性を定義するために使用されます。 -

pktcSigEndPntConfigTable  OBJECT-TYPE
    SYNTAX        SEQUENCE OF PktcSigEndPntConfigEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        " This table describes the information pertaining to each
          endpoint of the MTA.  All entries in this table represent
          the provisioned endpoints provisioned with the information
          required by the MTA to maintain the NCS protocol
          communication with the CMS.  Each endpoint can be assigned
          to its own CMS.  If the specific endpoint does not have
          the corresponding CMS information in this table, the
          endpoint is considered as not provisioned with voice
          services.  Objects in this table do not persist across
          MTA reboots."
   ::=  { pktcSigEndPntConfigObjects 1 }
        
pktcSigEndPntConfigEntry  OBJECT-TYPE
    SYNTAX        PktcSigEndPntConfigEntry
    MAX-ACCESS    not-accessible
    STATUS        current
    DESCRIPTION
        "Each entry in the pktcSigEndPntConfigTable represents
         required signaling parameters for the specific endpoint
         provisioned with voice services.  The conceptual rows MUST
         NOT persist across MTA reboots."
    INDEX { ifIndex }
    ::= { pktcSigEndPntConfigTable 1 }
        
PktcSigEndPntConfigEntry  ::= SEQUENCE {
    pktcSigEndPntConfigCallAgentId             SnmpAdminString,
    pktcSigEndPntConfigCallAgentUdpPort        InetPortNumber,
    pktcSigEndPntConfigPartialDialTO           Unsigned32,
    pktcSigEndPntConfigCriticalDialTO          Unsigned32,
    pktcSigEndPntConfigBusyToneTO              Unsigned32,
    pktcSigEndPntConfigDialToneTO              Unsigned32,
    pktcSigEndPntConfigMessageWaitingTO        Unsigned32,
    pktcSigEndPntConfigOffHookWarnToneTO       Unsigned32,
    pktcSigEndPntConfigRingingTO               Unsigned32,
    pktcSigEndPntConfigRingBackTO              Unsigned32,
    pktcSigEndPntConfigReorderToneTO           Unsigned32,
    pktcSigEndPntConfigStutterDialToneTO       Unsigned32, pktcSigEndPntConfigTSMax                   Unsigned32,
    pktcSigEndPntConfigMax1                    Unsigned32,
    pktcSigEndPntConfigMax2                    Unsigned32,
    pktcSigEndPntConfigMax1QEnable             TruthValue,
    pktcSigEndPntConfigMax2QEnable             TruthValue,
    pktcSigEndPntConfigMWD                     Unsigned32,
    pktcSigEndPntConfigTdinit                  Unsigned32,
    pktcSigEndPntConfigTdmin                   Unsigned32,
    pktcSigEndPntConfigTdmax                   Unsigned32,
    pktcSigEndPntConfigRtoMax                  Unsigned32,
    pktcSigEndPntConfigRtoInit                 Unsigned32,
    pktcSigEndPntConfigLongDurationKeepAlive   Unsigned32,
    pktcSigEndPntConfigThist                   Unsigned32,
    pktcSigEndPntConfigStatus                  RowStatus,
    pktcSigEndPntConfigCallWaitingMaxRep       Unsigned32,
    pktcSigEndPntConfigCallWaitingDelay        Unsigned32,
    pktcSigEndPntStatusCallIpAddressType       InetAddressType,
    pktcSigEndPntStatusCallIpAddress           InetAddress,
    pktcSigEndPntStatusError                   INTEGER,
    pktcSigEndPntConfigMinHookFlash            Unsigned32,
    pktcSigEndPntConfigMaxHookFlash            Unsigned32,
    pktcSigEndPntConfigPulseDialInterdigitTime Unsigned32,
    pktcSigEndPntConfigPulseDialMinMakeTime    Unsigned32,
    pktcSigEndPntConfigPulseDialMaxMakeTime    Unsigned32,
    pktcSigEndPntConfigPulseDialMinBreakTime   Unsigned32,
    pktcSigEndPntConfigPulseDialMaxBreakTime   Unsigned32
    }
        

pktcSigEndPntConfigCallAgentId OBJECT-TYPE SYNTAX SnmpAdminString(SIZE (3..255)) MAX-ACCESS read-create STATUS current DESCRIPTION " This object contains a string indicating the call agent name (e.g., ca@example.com). The call agent name, after the character '@', MUST be a fully qualified domain name (FQDN) and MUST have a corresponding pktcMtaDevCmsFqdn entry in the pktcMtaDevCmsTable. The object pktcMtaDevCmsFqdn is defined in the PacketCable MIBMTA Specification. For each particular endpoint, the MTA MUST use the current value of this object to communicate with the corresponding CMS. The MTA MUST update this object with the value of the 'Notified Entity' parameter of the NCS message. Because of the high importance of this object to the ability of the MTA to maintain reliable NCS communication with the CMS, it is highly recommended not to change this object's value using SNMP during normal operation."

pktcSigEndPntConfigCallAgentIdのOBJECT-TYPE SYNTAXれるSnmpAdminString(SIZE(3..255))MAX-ACCESSはリード作成しますステータス現在の説明は「このオブジェクトは、コールエージェント名(例えば、ca@example.com)を示す文字列が含まれています。コールエージェント名、文字の後に「@」、完全修飾ドメイン名(FQDN)でなければならないとpktcMtaDevCmsTableで対応するpktcMtaDevCmsFqdnエントリを持たなければなりません。オブジェクトpktcMtaDevCmsFqdnがPacketCableのMIBMTA仕様で定義されています。それぞれの特定のエンドポイントについて、MTAが電流を使用しなければなりませんこのオブジェクトの値は、対応するCMSと通信する。MTAはNCSメッセージの「通知さエンティティのパラメータの値と、このオブジェクトを更新する必要があります。ため信頼NCSを維持するために、MTAの能力へのこのオブジェクトの高い重要性CMSとの通信には、非常に通常動作時にSNMPを使用して、このオブジェクトの値を変更しないことをお勧めします。」

    ::= {  pktcSigEndPntConfigEntry 1 }
        
pktcSigEndPntConfigCallAgentUdpPort    OBJECT-TYPE
    SYNTAX      InetPortNumber (1025..65535)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " This object contains the current value of the User
          Datagram Protocol (UDP) receive port on which the
          call agent will receive NCS from the endpoint.
          For each particular endpoint, the MTA MUST use the current
          value of this object to communicate with the corresponding
          CMS.  The MTA MUST update this object with the value of the
          'Notified Entity' parameter of the NCS message.  If the
          Notified Entity parameter does not contain a CallAgent
          port, the MTA MUST update this object with the default
          value of 2727.  Because of the high importance of this
          object to the ability of the MTA to maintain reliable NCS
          communication with the CMS, it is highly recommended not
          to change this object's value using SNMP during normal
          operation."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 2727 }
    ::= { pktcSigEndPntConfigEntry 2 }
        
pktcSigEndPntConfigPartialDialTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        "This object contains the value of the partial dial
         time out.
         The time out (TO) elements are intended to limit the time a
         tone or frequency is generated.  When this MIB object is set
         to a value of '0', the MTA MUST NOT generate the
         corresponding frequency or tone, regardless of the
         definitions pertaining to frequency, tone duration, or
         cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 16 }
    ::= { pktcSigEndPntConfigEntry 3 }
        

pktcSigEndPntConfigCriticalDialTO OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds"

pktcSigEndPntConfigCriticalDialTOのOBJECT-TYPE構文Unsigned32 UNITSの "秒"

    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        "This object contains the value of the critical
         dial time out.
         The time out (TO) elements are intended to limit the time a
         tone or frequency is generated.  When this MIB object is set
         to a value of '0', the MTA MUST NOT generate the
         corresponding frequency or tone, regardless of the
         definitions pertaining to frequency, tone duration, or
         cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 4 }
    ::= { pktcSigEndPntConfigEntry 4 }
        
pktcSigEndPntConfigBusyToneTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for busy
          tone.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 30 }
    ::= { pktcSigEndPntConfigEntry 5 }
        
pktcSigEndPntConfigDialToneTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for dial
          tone.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 16 }
    ::= { pktcSigEndPntConfigEntry 6 }
        
pktcSigEndPntConfigMessageWaitingTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for message
          waiting indicator.  The MTA MUST NOT update this object
          with the value provided in the NCS message (if
          present).  If the value of the object is modified by the
          SNMP Manager application, the MTA MUST use the new value
          as a default only for a new signal requested by the NCS
          message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 16 }
    ::= { pktcSigEndPntConfigEntry 7 }
        
pktcSigEndPntConfigOffHookWarnToneTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for the
          off-hook warning tone.  The MTA MUST NOT update this object
          with the value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Manager application, the MTA MUST use the new value as a default
          only for a new signal requested by the NCS message.  The
          time out (TO) elements are intended to limit the time a tone
          or frequency is generated.  When this MIB object is set to a
          value of '0', the MTA MUST NOT generate the corresponding
          frequency or tone, regardless of the definitions pertaining
          to frequency, tone duration, or cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 0 }
    ::= { pktcSigEndPntConfigEntry 8 }
        
pktcSigEndPntConfigRingingTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for
          ringing.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 180 }
    ::= { pktcSigEndPntConfigEntry 9 }
        
pktcSigEndPntConfigRingBackTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for ring
          back.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 180 }
    ::= { pktcSigEndPntConfigEntry 10 }
        
pktcSigEndPntConfigReorderToneTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for reorder
          tone.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the
          corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL    { 30 }
    ::= { pktcSigEndPntConfigEntry 11 }
        
pktcSigEndPntConfigStutterDialToneTO     OBJECT-TYPE
    SYNTAX       Unsigned32
    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the default time out value for stutter
          dial tone.  The MTA MUST NOT update this object with the
          value provided in the NCS message (if present).  If
          the value of the object is modified by the SNMP Management
          Station, the MTA MUST use the new value as a default only
          for a new signal requested by the NCS message.
          The time out (TO) elements are intended to limit the time
          a tone or frequency is generated.  When this MIB object is
          set to a value of '0', the MTA MUST NOT generate the corresponding frequency or tone, regardless of the
          definitions pertaining to frequency, tone duration, or
          cadence."
    REFERENCE
          "PacketCable NCS Specification"
    DEFVAL    { 16 }
    ::= { pktcSigEndPntConfigEntry 12 }
        

pktcSigEndPntConfigTSMax OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object is used as part of an NCS retransmission algorithm. Prior to any retransmission, the MTA must check to make sure that the time elapsed since the sending of the initial datagram does not exceed the value specified by this MIB object. If more than Tsmax time has elapsed, then the retransmissions MUST cease.

pktcSigEndPntConfigTSMax OBJECT-TYPE構文Unsigned32 MAX-ACCESSはリード作成しますステータス現在の説明は「このMIBオブジェクトはNCS再送アルゴリズムの一部として使用されている。前の任意の再送への送信があるため、MTAは、時間が経過していることを確認するためにチェックしなければなりません初期のデータグラムは、このMIBオブジェクトによって指定された値を超えていない。Tsmax時間以上が経過した場合、再送信は中止しなければなりません。

            Refer to the MIB object pktcSigEndPntConfigThist for
            information on when the endpoint becomes disconnected."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 20 }
    ::= { pktcSigEndPntConfigEntry 13 }
        
pktcSigEndPntConfigMax1     OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object contains the suspicious error threshold for
         signaling messages.  The pktcSigEndPntConfigMax1 object
         indicates the retransmission threshold at which the MTA MAY
         actively query the domain name server (DNS) in order to
         detect the possible change of call agent interfaces."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 5 }
    ::= { pktcSigEndPntConfigEntry 14 }
        

pktcSigEndPntConfigMax2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION

pktcSigEndPntConfigMax2のOBJECT-TYPE構文Unsigned32 MAX-ACCESSはリード作成しますステータス現在の説明

        "This object contains the disconnect error threshold for
         signaling messages.  The pktcSigEndPntConfigMax2 object
         indicates the retransmission threshold at which the MTA
         SHOULD contact the DNS one more time to see if any other
         interfaces to the call agent have become available."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 7 }
    ::= { pktcSigEndPntConfigEntry 15 }
        
pktcSigEndPntConfigMax1QEnable     OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object enables/disables the Max1 domain name server
         (DNS) query operation when the pktcSigEndPntConfigMax1
         threshold has been reached.
         A value of true(1) indicates enabling, and a value of
         false(2) indicates disabling."
    DEFVAL { true }
    ::= { pktcSigEndPntConfigEntry 16 }
        
pktcSigEndPntConfigMax2QEnable     OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object enables/disables the Max2 domain name server
         (DNS) query operation when the pktcSigEndPntConfigMax2
         threshold has been reached.
         A value of true(1) indicates enabling, and a value of
         false(2) indicates disabling."
    DEFVAL { true }
    ::= { pktcSigEndPntConfigEntry 17 }
        

pktcSigEndPntConfigMWD OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum Waiting Delay (MWD) contains the maximum number of seconds an MTA waits, after powering on, before initiating the restart procedure with the call agent." REFERENCE "PacketCable NCS Specification" DEFVAL { 600 }

pktcSigEndPntConfigMWDのOBJECT-TYPE構文Unsigned32 UNITSの「秒」MAX-ACCESSはリード作成しますステータス現在の説明は「最大待機遅延(MWD)は、コールエージェントと再起動の手順を開始する前に、電源投入後、秒MTA待機の最大数が含まれています。 " REFERENCE "PacketCableのNCS仕様" DEFVAL {600}

    ::= { pktcSigEndPntConfigEntry 18 }
        

pktcSigEndPntConfigTdinit OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "This MIB object represents the 'disconnected' initial waiting delay within the context of an MTA's 'disconnected procedure'. The 'disconnected procedure' is initiated when an endpoint becomes 'disconnected' while attempting to communicate with a call agent.

pktcSigEndPntConfigTdinitのOBJECT-TYPE構文Unsigned32 UNITSの「秒」MAX-ACCESSはリード作成しますステータス現在の説明は「このMIBオブジェクトは、 『切断手順』がときに開始される。MTAの 『切断プロシージャ』の文脈の中で 『切断』の初期待機遅延を表しコールエージェントと通信しようとしたときに、エンドポイントは「切断」になります。

         The 'disconnected timer' associated with the 'disconnected
         Procedure' is initialized to a random value, uniformly
         distributed between zero and the value contained in this
         MIB object.
        
         For more information on the usage of this timer, please
         refer to the PacketCable NCS Specification."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 15 }
    ::= { pktcSigEndPntConfigEntry 19 }
        
pktcSigEndPntConfigTdmin     OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
            "This MIB object represents the 'disconnected' minimum
             waiting delay within the context of an MTA's
             'disconnected procedure', specifically when local user
             activity is detected.
             The 'disconnected procedure' is initiated when
             an endpoint becomes 'disconnected' while attempting to
             communicate with a call agent.
             For more information on the usage of this timer, please
             refer to the PacketCable NCS Specification."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 15 }
    ::= { pktcSigEndPntConfigEntry 20 }
        

pktcSigEndPntConfigTdmax OBJECT-TYPE SYNTAX Unsigned32

pktcSigEndPntConfigTdmaxのOBJECT-TYPE構文Unsigned32

    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " This object contains the maximum number of seconds the MTA
          waits, after a disconnect, before initiating the
          disconnected procedure with the call agent.
           "
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 600 }
    ::= { pktcSigEndPntConfigEntry 21 }
        
pktcSigEndPntConfigRtoMax     OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        "This object specifies the maximum number of seconds the MTA
         waits for a response to an NCS message before initiating
         a retransmission."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 4 }
    ::= { pktcSigEndPntConfigEntry 22 }
        
pktcSigEndPntConfigRtoInit     OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " This object contains the initial number of seconds for the
          retransmission timer."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 200 }
    ::= { pktcSigEndPntConfigEntry 23 }
        

pktcSigEndPntConfigLongDurationKeepAlive OBJECT-TYPE SYNTAX Unsigned32 UNITS "minutes" MAX-ACCESS read-create STATUS current DESCRIPTION " Specifies a time out value, in minutes, for sending long duration call notification messages."

pktcSigEndPntConfigLongDurationKeepAlive OBJECT-TYPE構文Unsigned32 UNITSの「分」MAX-ACCESSはリード作成しますステータス現在の説明は「長時間の通話通知メッセージを送信するために、分単位で、タイムアウト値を指定します。」

    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 60 }
    ::= { pktcSigEndPntConfigEntry 24 }
        
pktcSigEndPntConfigThist  OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "seconds"
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " Time out period, in seconds, before no response is declared."
    REFERENCE
        "PacketCable NCS Specification"
    DEFVAL { 30 }
    ::= { pktcSigEndPntConfigEntry 25 }
        
pktcSigEndPntConfigStatus     OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " This object contains the Row Status associated with the
          pktcSigEndPntConfigTable.  There are no restrictions or
          dependencies amidst the columnar objects before this
          row can be activated or for modifications of the
          columnar objects when this object is set to a
          value of 'active(1)."
    ::= { pktcSigEndPntConfigEntry 26 }
        
pktcSigEndPntConfigCallWaitingMaxRep     OBJECT-TYPE
    SYNTAX      Unsigned32 (0..10)
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
        " This object contains the default value of the maximum
          number of repetitions of the Call Waiting tone that the
          MTA will play from a single CMS request.  The MTA MUST NOT
          update this object with the information provided in the
          NCS message (if present).  If the value of the object is
          modified by the SNMP Manager application, the MTA MUST use
          the new value as a default only for a new signal
          requested by the NCS message."
    DEFVAL    { 1 }
    ::= { pktcSigEndPntConfigEntry 27 }
        

pktcSigEndPntConfigCallWaitingDelay OBJECT-TYPE SYNTAX Unsigned32 (1..100)

pktcSigEndPntConfigCallWaitingDelayのOBJECT-TYPE構文Unsigned32(1..100)

    UNITS        "seconds"
    MAX-ACCESS   read-create
    STATUS       current
    DESCRIPTION
        " This object contains the delay between repetitions of the
          Call Waiting tone that the MTA will play from a single CMS
          request."
    DEFVAL    { 10 }
    ::= { pktcSigEndPntConfigEntry 28 }
        

pktcSigEndPntStatusCallIpAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION " This object contains the type of Internet address contained in the MIB object 'pktcSigEndPntStatusCallIpAddress'.

pktcSigEndPntStatusCallIpAddressTypeのOBJECT-TYPE構文InetAddressType MAX-ACCESS read-onlyステータス現在の説明は「このオブジェクトは、MIBオブジェクトのpktcSigEndPntStatusCallIpAddress "に含まれているインターネット・アドレスの種類が含まれています。

         Since pktcSigEndPntStatusCallIpAddress is expected to
         contain an IP address, a value of dns(16) is disallowed."
        
    ::= { pktcSigEndPntConfigEntry 29 }
        

pktcSigEndPntStatusCallIpAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION " This MIB object contains the chosen IP address of the CMS currently being used for the corresponding endpoint.

pktcSigEndPntStatusCallIpAddressのOBJECT-TYPE構文InetAddress MAX-ACCESS read-onlyステータス現在の説明は「このMIBオブジェクトは、現在、該当するエンドポイントで使用されているCMSの選択されたIPアドレスが含まれています。

         The device determines the IP address by using DNS to
         resolve the IP address of the CMS from the FQDN stored in
         the MIB object 'pktcSigEndPntConfigCallAgentId'.  The
         processes are outlined in the PacketCable NCS and Security
         specifications, and MUST be followed by the MTA.
        
         The IP address type contained in this MIB object is
         indicated by pktcSigEndPntStatusCallIpAddressType."
    REFERENCE
        "PacketCable NCS Specification;
         PacketCable Security specification, [PKT-SP-SEC]."
::= { pktcSigEndPntConfigEntry 30 }
        
pktcSigEndPntStatusError  OBJECT-TYPE
    SYNTAX INTEGER {
               operational (1),
               noSecurityAssociation (2), disconnected (3)
             }
    MAX-ACCESS   read-only
    STATUS  current
    DESCRIPTION
       " This object contains the error status for this interface.
         The operational status indicates that all operations
         necessary to put the line in service have occurred, and the
         CMS has acknowledged the Restart In Progress (RSIP)
         message successfully.  If pktcMtaDevCmsIpsecCtrl is enabled
         for the associated call agent, the noSecurityAssociation
         status indicates that no Security Association (SA) yet
         exists for this endpoint.  If pktcMtaDevCmsIpsecCtrl is
         disabled for the associated call agent, the
         noSecurityAssociation status is not applicable and should
         not be used by the MTA.  The disconnected status indicates
         one of the following two:
         If pktcMtaDevCmsIpsecCtrl is disabled, then no security
         association is involved with this endpoint.  The NCS
         signaling software is in process of establishing the NCS
         signaling link via an RSIP exchange.
         Otherwise, when pktcMtaDevCmsIpsecCtrl is enabled,
         security Association has been established, and the NCS
         signaling software is in process of establishing the NCS
         signaling link via an RSIP exchange."
    ::= { pktcSigEndPntConfigEntry 31 }
        
pktcSigEndPntConfigMinHookFlash    OBJECT-TYPE
    SYNTAX       Unsigned32 (20..1550)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the minimum time a line needs to be on-hook for a
          valid hook flash.  The value of this object MUST be
          greater than the value of
          pktcSigEndPntConfigPulseDialMaxBreakTime.  The value of
          pktcSigEndPntConfigMinHookFlash MUST be less than
          pktcSigEndPntConfigMaxHookFlash.  This object MUST only be
          set via the MTA configuration during the provisioning
          process.
             Furthermore, given the possibility for the 'pulse dial'
             and 'hook flash' to overlap, the value of this object
             MUST be greater than the value contained by the MIB
             Object 'pktcSigEndPntConfigPulseDialMaxMakeTime'."
    DEFVAL { 300 }
    ::= { pktcSigEndPntConfigEntry 32 }
        
pktcSigEndPntConfigMaxHookFlash    OBJECT-TYPE
    SYNTAX       Unsigned32 (20..1550)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the maximum time a line needs to be on-hook for a
          valid hook flash.  The value of
          pktcSigEndPntConfigMaxHookFlash MUST be greater than
          pktcSigEndPntConfigMinHookFlash.  This object MUST only be
          set via the MTA configuration during the provisioning
          process."
    DEFVAL { 800 }
    ::= { pktcSigEndPntConfigEntry 33 }
        
pktcSigEndPntConfigPulseDialInterdigitTime    OBJECT-TYPE
    SYNTAX       Unsigned32 (100..1500)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the pulse dial inter-digit time out.  This object
          MUST only be set via the MTA configuration during the
          provisioning process."
    DEFVAL { 100 }
    ::= { pktcSigEndPntConfigEntry 34 }
        
pktcSigEndPntConfigPulseDialMinMakeTime    OBJECT-TYPE
    SYNTAX       Unsigned32 (20..200)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the minimum make pulse width for the dial pulse.
          The value of pktcSigEndPntConfigPulseDialMinMakeTime MUST
          be less than pktcSigEndPntConfigPulseDialMaxMakeTime.  This
          object MUST only be set via the MTA configuration during
          the provisioning process."
    DEFVAL { 25 }
    ::= { pktcSigEndPntConfigEntry 35 }
        

pktcSigEndPntConfigPulseDialMaxMakeTime OBJECT-TYPE SYNTAX Unsigned32 (20..200) UNITS "Milliseconds" MAX-ACCESS read-only STATUS current DESCRIPTION " This is the maximum make pulse width for the dial pulse.

pktcSigEndPntConfigPulseDialMaxMakeTimeのOBJECT-TYPE構文Unsigned32(20..200)UNITS「ミリ秒」MAX-ACCESS read-onlyステータス現在の説明は「これは、ダイヤルパルスの最大メイクパルス幅です。

          The value of pktcSigEndPntConfigPulseDialMaxMakeTime MUST
          be greater than pktcSigEndPntConfigPulseDialMinMakeTime.
          This object MUST only be provided via the configuration
          file during the provisioning process.
          Furthermore, given the possibility for the 'pulse dial'
          and 'hook flash' to overlap, the value of this object MUST
          be less than the value contained by the MIB object
          pktcSigEndPntConfigMinHookFlash."
    DEFVAL { 55 }
    ::= { pktcSigEndPntConfigEntry 36 }
        
pktcSigEndPntConfigPulseDialMinBreakTime    OBJECT-TYPE
    SYNTAX       Unsigned32 (20..200)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the minimum break pulse width for the dial pulse.
          The value of pktcSigEndPntConfigPulseDialMinBreakTime MUST
          be less than pktcSigEndPntConfigPulseDialMaxBreakTime.
          This object must only be provided via the configuration
          file during the provisioning process."
    DEFVAL { 45 }
    ::= { pktcSigEndPntConfigEntry 37 }
        
pktcSigEndPntConfigPulseDialMaxBreakTime    OBJECT-TYPE
    SYNTAX       Unsigned32 (20..200)
    UNITS        "Milliseconds"
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        " This is the maximum break pulse width for the dial pulse.
          The value of pktcSigEndPntConfigPulseDialMaxBreakTime MUST
          be greater than pktcSigEndPntConfigPulseDialMinBreakTime.
          This object MUST only be provided via the configuration
          file during the provisioning process."
    DEFVAL { 75 }
    ::= { pktcSigEndPntConfigEntry 38 }
        
--
-- notification group is for future extension.
--
pktcSigNotification  OBJECT IDENTIFIER ::= { pktcIetfSigMib 0 }
pktcSigConformance   OBJECT IDENTIFIER ::= { pktcIetfSigMib 2 }
pktcSigCompliances   OBJECT IDENTIFIER ::= { pktcSigConformance 1 }
pktcSigGroups        OBJECT IDENTIFIER ::= { pktcSigConformance 2 }
        

--

--

-- compliance statements --

- コンプライアンスステートメント -

pktcSigBasicCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION " The compliance statement for MTAs that implement NCS signaling."

pktcSigBasicCompliance MODULE-COMPLIANCEステータス現在の説明「NCSシグナリングを実装するMTAの準拠宣言。」

MODULE -- pktcIetfSigMib

MODULE - pktcIetfSigMib

---
-- Unconditionally mandatory groups for all MTAs
---
        
MANDATORY-GROUPS {
    pktcSigDeviceGroup,
    pktcSigEndpointGroup
}
---
-- Conditionally mandatory groups for MTAs
---
        

GROUP pktcInternationalGroup DESCRIPTION " This group is mandatory only for MTAs implementing international telephony features."

GROUP pktcInternationalGroup DESCRIPTION「このグループは唯一の国際電話機能を実装するためのMTA必須です。」

GROUP pktcLLinePackageGroup DESCRIPTION " This group is mandatory only for MTAs implementing the L line package."

GROUP pktcLLinePackageGroupの説明は「このグループはLラインパッケージを実装するMTAの必須です。」

GROUP pktcELinePackageGroup
    DESCRIPTION
        " This group is mandatory only for MTAs implementing the E
          Line Package."
    ::={ pktcSigCompliances 1 }
        
pktcSigDeviceGroup  OBJECT-GROUP
    OBJECTS {
    pktcSigDevCodecMax,
    pktcSigDevEchoCancellation,
    pktcSigDevSilenceSuppression,
    pktcSigDevR0Cadence,
    pktcSigDevR1Cadence,
    pktcSigDevR2Cadence,
    pktcSigDevR3Cadence, pktcSigDevR4Cadence,
    pktcSigDevR5Cadence,
    pktcSigDevR6Cadence,
    pktcSigDevR7Cadence,
    pktcSigDevRgCadence,
    pktcSigDevRsCadence,
    pktcSigDefCallSigDscp,
    pktcSigDefMediaStreamDscp,
    pktcSigDevVmwiMode,
    pktcSigCapabilityType,
    pktcSigCapabilityVersion,
    pktcSigCapabilityVendorExt,
    pktcSigDefNcsReceiveUdpPort
    }
    STATUS current
    DESCRIPTION
          "Group of MIB objects containing signaling configuration
           information that is applicable per-device."
    ::= { pktcSigGroups 1 }
        
pktcSigEndpointGroup  OBJECT-GROUP
    OBJECTS {
    pktcSigEndPntConfigCallAgentId,
    pktcSigEndPntConfigCallAgentUdpPort,
    pktcSigEndPntConfigPartialDialTO,
    pktcSigEndPntConfigCriticalDialTO,
    pktcSigEndPntConfigBusyToneTO,
    pktcSigEndPntConfigDialToneTO,
    pktcSigEndPntConfigMessageWaitingTO,
    pktcSigEndPntConfigOffHookWarnToneTO,
    pktcSigEndPntConfigRingingTO,
    pktcSigEndPntConfigRingBackTO,
    pktcSigEndPntConfigReorderToneTO,
    pktcSigEndPntConfigStutterDialToneTO,
    pktcSigEndPntConfigTSMax,
    pktcSigEndPntConfigMax1,
    pktcSigEndPntConfigMax2,
    pktcSigEndPntConfigMax1QEnable,
    pktcSigEndPntConfigMax2QEnable,
    pktcSigEndPntConfigMWD,
    pktcSigEndPntConfigTdinit,
    pktcSigEndPntConfigTdmin,
    pktcSigEndPntConfigTdmax,
    pktcSigEndPntConfigRtoMax,
    pktcSigEndPntConfigRtoInit,
    pktcSigEndPntConfigLongDurationKeepAlive,
    pktcSigEndPntConfigThist,
    pktcSigEndPntConfigStatus, pktcSigEndPntConfigCallWaitingMaxRep,
    pktcSigEndPntConfigCallWaitingDelay,
    pktcSigEndPntStatusCallIpAddressType,
    pktcSigEndPntStatusCallIpAddress,
    pktcSigEndPntStatusError
    }
    STATUS current
    DESCRIPTION
          "Group of MIB objects containing signaling configuration
           information that is applicable per-endpoint."
    ::= { pktcSigGroups 2 }
        
pktcInternationalGroup    OBJECT-GROUP
    OBJECTS {
    pktcSigEndPntConfigMinHookFlash,
    pktcSigEndPntConfigMaxHookFlash,
    pktcSigEndPntConfigPulseDialInterdigitTime,
    pktcSigEndPntConfigPulseDialMinMakeTime,
    pktcSigEndPntConfigPulseDialMaxMakeTime,
    pktcSigEndPntConfigPulseDialMinBreakTime,
    pktcSigEndPntConfigPulseDialMaxBreakTime,
    pktcSigDevRingCadence,
    pktcSigDevCidSigProtocol,
    pktcSigDevCidDelayAfterLR,
    pktcSigDevCidDtmfStartCode,
    pktcSigDevCidDtmfEndCode,
    pktcSigDevVmwiSigProtocol,
    pktcSigDevVmwiDelayAfterLR,
    pktcSigDevVmwiDtmfStartCode,
    pktcSigDevVmwiDtmfEndCode,
    pktcSigDevrpAsDtsDuration,
    pktcSigDevCidMode,
    pktcSigDevCidAfterRing,
    pktcSigDevCidAfterDTAS,
    pktcSigDevCidAfterRPAS,
    pktcSigDevRingAfterCID,
    pktcSigDevCidDTASAfterLR,
    pktcSigDevVmwiMode,
    pktcSigDevVmwiAfterDTAS,
    pktcSigDevVmwiAfterRPAS,
    pktcSigDevVmwiDTASAfterLR,
    pktcSigPowerRingFrequency,
    pktcSigPulseSignalFrequency,
    pktcSigPulseSignalDbLevel,
    pktcSigPulseSignalDuration,
    pktcSigPulseSignalPulseInterval,
    pktcSigPulseSignalRepeatCount,
    pktcSigDevToneDbLevel, pktcSigDevToneFreqCounter,
    pktcSigDevToneWholeToneRepeatCount,
    pktcSigDevToneSteady,
    pktcSigDevToneFirstFreqValue,
    pktcSigDevToneSecondFreqValue,
    pktcSigDevToneThirdFreqValue,
    pktcSigDevToneFourthFreqValue,
    pktcSigDevToneFreqMode,
    pktcSigDevToneFreqAmpModePrtg,
    pktcSigDevToneFreqOnDuration,
    pktcSigDevToneFreqOffDuration,
    pktcSigDevToneFreqRepeatCount
    }
    STATUS current
    DESCRIPTION
        " Group of objects that extend the behavior of existing
          objects to support operations in the widest possible set
          of international marketplaces.  Note that many of these
          objects represent a superset of behaviors described in
          other objects within this MIB module."
    ::= { pktcSigGroups 3 }
        
pktcLLinePackageGroup  OBJECT-GROUP
    OBJECTS {
    pktcSigDevR0Cadence,
    pktcSigDevR1Cadence,
    pktcSigDevR2Cadence,
    pktcSigDevR3Cadence,
    pktcSigDevR4Cadence,
    pktcSigDevR5Cadence,
    pktcSigDevR6Cadence,
    pktcSigDevR7Cadence,
    pktcSigDevRgCadence,
    pktcSigDevRsCadence
    }
    STATUS current
    DESCRIPTION
    "Group of Objects to support the L line package."
    ::= { pktcSigGroups 4 }
        
pktcELinePackageGroup  OBJECT-GROUP
    OBJECTS {
    pktcSigDevR0Cadence,
    pktcSigDevR1Cadence,
    pktcSigDevR2Cadence,
    pktcSigDevR3Cadence,
    pktcSigDevR4Cadence,
    pktcSigDevR5Cadence, pktcSigDevR6Cadence,
    pktcSigDevR7Cadence,
    pktcSigDevRgCadence,
    pktcSigDevRsCadence,
    pktcSigPulseSignalFrequency,
    pktcSigPulseSignalDbLevel,
    pktcSigPulseSignalDuration,
    pktcSigPulseSignalPulseInterval,
    pktcSigPulseSignalRepeatCount,
    pktcSigDevRingCadence
    }
    STATUS current
    DESCRIPTION
        "Group of Objects to support the E line package."
    ::= { pktcSigGroups 5 }
        

END

終わり

6. Examples
6.例

This section provides a couple of examples, specifically related to the MIB tables pktcSigDevToneTable and pktcSigDevMultiFreqToneTable.

このセクションでは、MIBテーブルpktcSigDevToneTableとpktcSigDevMultiFreqToneTableに特異的に関連する例をいくつか提供します。

Example A: Call Waiting Tone Defined per [ITU-T E.180]:

例A:[ITU-T E.180]ごとに定義ウェイティングトーンを呼び出します。

1) 400 Hz AM modulated by 16 Hz, on for 500ms at -4 dBm 2) 400 Hz AM modulated by 16 Hz, off for 400ms 3) 400 Hz not AM modulated, on for 50 ms at -4 dBm 4) 400 Hz not AM modulated, off for 450 ms 5) 400 Hz not AM modulated, on for 50 ms at -4 dBm 6) 400 Hz not AM modulated, off for 3450 ms 7) 400 Hz not AM modulated, on for 50 ms at -4 dBm 8) 400 Hz not AM modulated, off for 450 ms 9) 400 Hz not AM modulated, on for 50 ms at -4 dBm 10) 400 Hz not AM modulated, off for 3450 ms 11) not repeated, not continuous

で-4 dBmの4 50msのために、変調されたAMない1)で-4 dBmで2 500msのために、16ヘルツで変調された400 HzのAM)を400msの3オフ16ヘルツで変調400 HzのAM)が400ヘルツ)400ヘルツしないで、50ミリ秒で、3450ミリ秒7)400 Hzの変調AMないためオフ、で-4 dBmで6)400 Hzの変調AMない50ミリ秒で、450ミリ秒5)400 Hzの変調AMないためオフ変調AM - 450ミリ秒9)400 Hzのは、AT -4 dBmで、10〜50ミリ秒のために、変調されたAMないオフ4 dBmの8)400ヘルツ3450ミリ11に対するオフ、AM変調しない400 Hz)で連続的ではなく、繰り返されない)、変調されたAMありません

Assume userDefined1(18) is assigned to this tone:

userDefined1(18)は、このトーンに割り当てられていると仮定します。

   pktcSigDevMultiFreqToneTable:
   ToneType|F-1|F-2|F-3|F-4|F-Mode|ModePrtg|DbL|OnDur|OffDur|Rep-Count
   ===================================================================
   18       400  16  0   0     1     90     -40  500   400      0
   18       400   0  0   0     2      0     -40   50   450      0
   18       400   0  0   0     2      0     -40   50  3450      0
   18       400   0  0   0     2      0     -40   50   450      0
   18       400   0  0   0     2      0     -40   50  3450      0
        
   pktcSigDevToneTable:
   ToneType|ToneFreqGroup|ToneFreqCounter|ToneRep-Count|Steady
   =============================================================
   18          1             5              0       false(2)
        

The single row of the pktcSigDevToneTable defines one multi-frequency group of five rows (ToneFreqCounter) defined in the pktcSigDevMultiFreqToneTable and instructs the MTA to play this group only once (non-repeatable as ToneRep-Count equals 0).

pktcSigDevToneTableの単一の行がpktcSigDevMultiFreqToneTableで定義された5列(ToneFreqCounter)のいずれかのマルチ周波数グループを定義し、一度だけ、このグループを再生するためにMTAを指示する(非反復ToneRep-Countが等しくなるように0)。

Example B - Congestion Tone - congestion(17):

例B - 輻輳トーン - 混雑(17):

Note: This example of an embedded cadence is based on an operator variation.

注:埋め込まれたケイデンスのこの例では、オペレータの変化に基づいています。

1) 400Hz on for 400ms -10 dBm

400msの-10 dBmのための1)400Hzのオン

2) 400Hz off for 350ms

350msの2)400Hzのオフ

3) 400Hz on for 225ms -4 dBm

3)400Hzの上225ms -4 dBmのため

4) 400Hz off for 525ms

525ms 4)400Hzのオフ

5) repeat (1) through (4) 5000 times or T0 time out (whichever is the shortest period)

スルー5)リピート(1)〜(4)の5000倍又はT0のタイムアウト(最短期間である方)

   pktcSigDevMultiFreqToneTable:
   ToneType|F-1|F-2|F-3|F-4|F-Mode|ModePrtg|DbL|OnDur|OffDur|Rep-Count
   ===================================================================
   17       400  0   0   0    2       0    -100  400   350      0
   17       400  0   0   0    2       0     -40  225   525      0
        
   pktcSigDevToneTable:
   ToneType|ToneFreqGroup|ToneFreqCounter|ToneRep-Count|Steady
   =============================================================
   17          1             2              5000        false(2)
        

Example C - Call Waiting Tone - callWaiting1(9):

例C - トーンコールウェイティング - callWaiting1(9):

1) 16 Hz is modulated to carry the 400 Hz signal, ModulationRate within 85%, on for 500msec, at -25 dBm or more but less than -14 dBm

1)16ヘルツは-25dBmで以上未満-14 dBm単位で、500msecのために、85%以内400 Hzの信号、ModulationRateを搬送するために変調されます

2) 16 Hz is modulated to carry the 400 Hz signal, off for 0 ~ 4 secs

2)16 Hzのは0〜4秒間オフ、400 Hzの信号を搬送するように変調されます

3) 400 Hz not modulated, on for 50 ms at -25 dBm or more but less than -14 dBm

3)400ヘルツは-25dBmで以上未満-14 dBm単位で50ミリ秒で、変調されていません

4) 400 Hz not modulated, off for 450ms

4)400ヘルツ450msのためのオフ、変調されません

5) 400 Hz not modulated, on for 50 ms at -25 dBm or more but less than -14 dBm

5)400ヘルツは-25dBmで以上未満-14 dBm単位で50ミリ秒で、変調されていません

6) 400 Hz not modulated, off for 3450ms ([4000 - (50+450+50)])

) - 6)400ヘルツ3450ms([(50 + 450 + 50 4000)]をオフ、変調されません

7) Steps 3 thru 6 are repeated

7)6から3が繰り返されます

   pktcSigDevMultiFreqToneTable:
   ToneType|F-1|F-2|F-3|F-4|F-Mode|ModePrtg|DbL|OnDur|OffDur|Rep-Count
   ===================================================================
   9        1   400 16  0   0     1     85     -25  500  1000      0
   9        2   400  0  0   0     2      0     -25   50   450      0
   9        3   400  0  0   0     2      0     -25   50  3450      0
        
   pktcSigDevToneTable:
   ToneType|ToneFreqGroup|ToneFreqCounter|ToneRep-Count|Steady
   =============================================================
   9           1             1              0       false(2)
   9           2             2              1       false(2)
        

The first row of the pktcSigDevToneTable table instructs the MTA to play one row (ToneFreqCounter) of the pktcSigDevMultiFreqToneTable table only once (non-repeatable as ToneRep-Count equals 0). The second row of the pktcSigDevToneTable table instructs the MTA to play the next two rows (ToneFreqCounter) of the pktcSigDevMultiFreqToneTable table and make this frequency group repeatable (ToneRep-Count is not 0).

pktcSigDevToneTable表の最初の行は、MTAは、一度だけpktcSigDevMultiFreqToneTableテーブルの一つの行(ToneFreqCounter)を再生するように指示する(非反復ToneRep-Countが等しくなるように0)。 pktcSigDevToneTableテーブルの2行目(ToneRep-Countが0ではない)pktcSigDevMultiFreqToneTableテーブルの次の2行(ToneFreqCounter)を再生し、この周波数グループが反復するためにMTAに指示します。

7. Acknowledgments
7.謝辞

The authors would like to thank the members of the IETF IPCDN working group and the CableLabs PacketCable Provisioning focus team for their contributions, comments, and suggestions.

作者は彼らの貢献、コメント、および提案のためのIETF IPCDNワーキンググループのメンバーとCableLabsのPacketCableのプロビジョニングフォーカスチームに感謝したいと思います。

Specifically, the following individuals are recognized:

具体的には、以下の個人が認識されます。

       Angela Lyda            Arris Interactive
       Romascanu, Dan         Avaya
       Chad Griffiths         Broadcom Corp.
       Eugene Nechamkin       Broadcom Corp.
       Jean-Francois Mule     CableLabs
       Matt A. Osman          CableLabs
       Klaus Hermanns         Cisco Systems, Inc.
       Rich Woundy            Comcast Corp.
       Bert Wijnen            Alcatel-Lucent
       Randy Presuhn          Mindspring
       Phillip Freyman        Motorola, Inc.
       Rick Vetter            Motorola, Inc.
       Sasha Medvinsky        Motorola, Inc.
       Wim De Ketelaere       tComLabs
       David De Reu           tComLabs
       Kristof Sercu          tComLabs
       Roy Spitzer            Telogy Networks, Inc.
       Itay Sherman           Texas Instruments, Inc.
       Mauricio Sanchez       Texas Instruments, Inc.
       Shivakumar Thangapandi Texas Instruments, Inc.
       Mike Heard             Consultant
        

The current editor (Sumanth Channabasappa) would like to recognize Phillip Freyman and Eugene Nechamkin for their contributions towards the international objects, and Stephane Bortzmeyer for assistance with the ABNF.

現在のエディタ(スーマンスChannabasappa)はABNFの支援のためにフィリップFreymanとユージンNechamkin国際オブジェクトへの彼らの貢献のため、そしてステファンBortzmeyerを認識したいと思います。

The editor also extends appreciation to the IPCDN co-chairs (Jean-Francois Mule, Rich Woundy) and Dan Romascanu for the numerous reviews and valuable comments. Special appreciation is extended to Bert Wijnen, as the MIB doctor, for his ever-useful and constructive comments.

エディタはまた、多くのレビューと貴重なコメントについてIPCDNの共同議長(ジャン=フランソワラバ、リッチWoundy)とダンRomascanuに感謝の意を拡張します。特別な感謝は彼のますます便利かつ建設的なコメントのために、MIB医師として、バートWijnenに拡張されます。

8. Security Considerations
8.セキュリティの考慮事項

There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations.

読み書きおよび/またはリード作成のMAX-ACCESS句でこのMIBモジュールで定義された管理オブジェクトの数があります。そのようなオブジェクトは、いくつかのネットワーク環境に敏感又は脆弱と考えることができます。適切な保護のない非安全な環境におけるSET操作のサポートはネットワーク操作のときにマイナスの影響を与える可能性があります。

The following Differentiated Services Code Point (DSCP) and mask objects are used to differentiate between various types of traffic in the service provider network:

下記の差別化サービスコードポイント(DSCP)とマスクオブジェクトは、サービスプロバイダーネットワーク内のトラフィックの様々な種類を区別するために使用されています。

        pktcSigDefCallSigDscp
        pktcSigDefMediaStreamDscp
        

These objects may contain information that may be sensitive from a business perspective. For example, they may represent a customer's service contract that a service provider chooses to apply to a customer's ingress or egress traffic. If these objects are SET maliciously, it may permit unmarked or inappropriately marked signaling and media traffic to enter the service provider network, resulting in unauthorized levels of service for customers.

これらのオブジェクトは、ビジネスの観点から、感受性がある可能性がある情報が含まれていてもよいです。例えば、彼らは、サービスプロバイダが顧客の入力または出力トラフィックに適用することを選択した顧客のサービス契約を表すことができます。これらのオブジェクトは悪意を持って設定されている場合、それは顧客のためのサービスの不正なレベルで、その結果、サービスプロバイダのネットワークを入力する覆面または不適切にマークさシグナリングおよびメディアトラフィックを許可することができます。

The following objects determine ring cadence, repeatable characteristics, signal duration, and caller id subscriber line protocol for telephony operation:

次のオブジェクトは、電話操作のための呼び出し音、反復特性、信号の持続時間、および発信者ID、加入者回線プロトコルを決定します。

        pktcSigDevR0Cadence
        pktcSigDevR1Cadence
        pktcSigDevR2Cadence
        pktcSigDevR3Cadence
        pktcSigDevR4Cadence
        pktcSigDevR5Cadence
        pktcSigDevR6Cadence
        pktcSigDevR7Cadence
        pktcSigDevRgCadence
        pktcSigDevRsCadence
        pktcSigDevCidSigProtocol
        pktcSigDevVmwiSigProtocol
        pktcSigPulseSignalDuration
        pktcSigPulseSignalPauseDuration
        

If these objects are SET maliciously, it may result in unwanted operation, or a failure to obtain telephony service from client (MTA) devices.

これらのオブジェクトは悪意を持って設定されている場合は、不要な操作、またはクライアント(MTA)のデバイスから電話サービスを得られない場合があります。

The objects in the pktcSigEndPntConfigTable are used for endpoint signaling. The pktcSigEndPntConfigCallAgentId object contains the name of the call agent, which includes the call agent Fully Qualified Domain Name (FQDN). If this object is SET maliciously, the MTA will not be able to communicate with the call agent, resulting in a disruption of telephony service. The pktcSigEndPntConfigCallAgentUdpPort object identifies the UDP port for NCS traffic. If this object is SET maliciously, the call agent will not receive NCS traffic from the MTA, also resulting in a disruption of telephony service.

pktcSigEndPntConfigTable内のオブジェクトは、エンドポイント・シグナリングのために使用されます。 pktcSigEndPntConfigCallAgentIdオブジェクトは、コールエージェント完全修飾ドメイン名(FQDN)を含んコールエージェントの名前が含まれています。このオブジェクトが悪意を持って設定されている場合は、MTAは、電話サービスの中断が生じ、コールエージェントと通信することができません。 pktcSigEndPntConfigCallAgentUdpPortオブジェクトは、NCSトラフィック用のUDPポートを識別します。このオブジェクトが悪意を持って設定されている場合は、コールエージェントはまた、電話サービスの中断が生じ、MTAからNCSトラフィックを受信しません。

Some of the readable objects in this MIB module (i.e., objects with a MAX-ACCESS other than not-accessible) may be considered sensitive or vulnerable in some network environments. It is thus important to control even GET and/or NOTIFY access to these objects and possibly to even encrypt the values of these objects when sending them over the network via SNMP. The most sensitive is pktcSigEndPntStatusCallIpAddress within pktcSigEndPntConfigTable. This information itself may be valuable to would-be attackers. Other MIB Objects of similar sensitivity include pktcSigEndPntStatusError, which can provide useful information to MTA impersonators, and pktcSigDevCodecMax, which can provide useful information for planning Denial of Service (DoS) attacks on MTAs.

このMIBモジュールで読み取り可能なオブジェクトの一部(すなわち、アクセス可能ではない以外MAX-ACCESS持つオブジェクト)は、いくつかのネットワーク環境に敏感又は脆弱と考えることができます。 GETおよび/またはこれらのオブジェクトへのアクセスを通知し、おそらくSNMPを通してネットワークの上にそれらを送信する場合でも、これらのオブジェクトの値を暗号化するためにも、制御することが重要です。最も敏感にpktcSigEndPntConfigTable内pktcSigEndPntStatusCallIpAddressです。この情報自体は-になり、攻撃者に価値があります。同様の感度の他のMIBオブジェクトは、MTAの上のサービス拒否(DoS)攻撃を計画するための有用な情報を提供することができMTAなりすましに有用な情報を提供することができpktcSigEndPntStatusError、およびpktcSigDevCodecMaxが含まれます。

SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPsec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module.

SNMPv3の前のSNMPバージョンは十分なセキュリティを含んでいませんでした。ネットワーク自体が(IPsecを使って、例えば)安全であっても、その後も、安全なネットワーク上で/ SETにアクセスし、GETだれに許容されているかのように何の制御(読み取り/変更/作成/削除)この内のオブジェクトが存在しませんMIBモジュール。

It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see [RFC3410], section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy).

実装がSNMPv3フレームワークで提供するようにセキュリティ機能を考えることが推奨される(認証とプライバシーのために)SNMPv3の暗号化メカニズムの完全なサポートを含む、([RFC3410]セクション8を参照)。

Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them.

さらに、SNMPv3の前のSNMPバージョンの展開はお勧めしません。代わりに、SNMPv3を展開すると、暗号化セキュリティを有効にすることをお勧めします。このMIBモジュールのインスタンスへのアクセスを与えるSNMP実体が適切にのみプリンシパル(ユーザ)にオブジェクトへのアクセスを提供するように設定されていることを確認するために、顧客/オペレータ責任実際にGETまたはSET(変化への正当な権利を有することです/)/削除、それらを作成します。

9. IANA Considerations
9. IANAの考慮事項

The MIB module in this document uses the following IANA-assigned OBJECT IDENTIFIER value recorded in the SMI Numbers registry:

この文書に記載されているMIBモジュールはSMI番号のレジストリに記録されている以下のIANAによって割り当てられたオブジェクト識別子の値を使用しています。

   Descriptor     OBJECT IDENTIFIER Value
   ----------     -----------------------
   pktcIetfSigMib     { mib-2 169 }
        
10. References
10.参考文献
10.1. Normative References
10.1. 引用規格

[PKT-SP-MIB-SIG-1.0] PacketCable(TM) 1.0 Signaling MIB Specification, Issued, PKT-SP-MIB-SIG-I09-050812, August 2005. http://www.packetcable.com/specifications/ http://www.cablelabs.com/specifications/archives

[PKT-SP-MIB-SIG-1.0]のPacketCable(TM)1.0シグナリングMIB仕様、発行、PKT-SP-MIB-SIG-I09-050812、2005年8月http://www.packetcable.com/specifications/ HTTP ://www.cablelabs.com/specifications/archives

[PKT-SP-MIB-SIG-1.5] PacketCable(TM) 1.5 Signaling MIB Specification, Issued, PKT-SP-MIB-SIG1.5-I01-050128, January 2005. http://www.packetcable.com/specifications/ http://www.cablelabs.com/specifications/archives

[PKT-SP-MIB-SIG1.5]のPacketCable(商標)1.5シグナリングMIB仕様、発行、PKT-SP-MIB-SIG1.5-I01-050128、2005年1月http://www.packetcable.com/specifications / http://www.cablelabs.com/specifications/archives

[PKT-SP-SEC] PacketCable Security Specification, Issued, PKT-SP-SEC-I12-050812, August 2005. http://www.packetcable.com/specifications/ http://www.cablelabs.com/specifications/archives

[PKT-SP-SEC] PacketCableのセキュリティ仕様書、発行、PKT-SP-SEC-I12-050812、2005年8月http://www.packetcable.com/specifications/ http://www.cablelabs.com/specifications/アーカイブ

[ITU-T-J169] IPCablecom Network Call Signaling (NCS) MIB requirements, J.169, ITU-T, March, 2001.

[ITU-T-J169] IPCablecomネットワークコールシグナリング(NCS)MIBの要件、J.169、ITU-T、2001年3月。

[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, March 1997.

[RFC2119]ブラドナーの、S.、 "要件レベルを示すためにRFCsにおける使用のためのキーワード"、BCP 14、RFC 2119、1997年3月。

[RFC2578] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Structure of Management Information Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

[RFC2578] McCloghrie、K.、パーキンス、D.、およびJ. Schoenwaelder、STD 58、RFC 2578、1999年4月 "管理情報バージョン2(SMIv2)の構造"。

[RFC2579] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Textual Conventions for SMIv2", STD 58, RFC 2579, April 1999.

[RFC2579] McCloghrie、K.、パーキンス、D.、およびJ. Schoenwaelder、 "SMIv2のためのテキストの表記法"、STD 58、RFC 2579、1999年4月。

[RFC2580] McCloghrie, K., Perkins, D., and J. Schoenwaelder, "Conformance Statements for SMIv2", STD 58, RFC 2580, April 1999.

[RFC2580] McCloghrie、K.、パーキンス、D.、およびJ. Schoenwaelder、 "SMIv2のための適合性宣言"、STD 58、RFC 2580、1999年4月。

[RFC3289] Baker, F., Chan, K., and A. Smith, "Management Information Base for the Differentiated Services Architecture", RFC 3289, May 2002.

[RFC3289]ベイカー、F.、チャン、K.、およびA.スミス、 "差別化サービスアーキテクチャのための管理情報ベース"、RFC 3289、2002年5月。

[RFC4001] Daniele, M., Haberman, B., Routhier, S., and J. Schoenwaelder, "Textual Conventions for Internet Network Addresses", RFC 4001, February 2005.

[RFC4001]ダニエル、M.、ハーバーマン、B.、Routhier、S.、およびJ. Schoenwaelder、 "インターネットネットワークアドレスのためのテキストの表記法"、RFC 4001、2005年2月。

[RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks", STD 62, RFC 3411, December 2002.

[RFC3411]ハリントン、D.、Presuhn、R.、およびB. Wijnenの、 "簡易ネットワーク管理プロトコル(SNMP)管理フレームワークを記述するためのアーキテクチャ"、STD 62、RFC 3411、2002年12月。

[RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB", RFC 2863, June 2000.

[RFC2863] McCloghrie、K.およびF. Kastenholzと、 "インターフェイスグループMIB"、RFC 2863、2000年6月。

[PKT-SP-CODEC] PacketCable Audio/Video Codecs Specification PKT-SP-CODEC-IO5-040113.

[PKT-SP-CODEC] PacketCableのオーディオ/ビデオコーデック仕様PKT-SP-CODEC-IO5-040113。

[PKT-SP-MGCP] PacketCable Network-Based Call Signaling Protocol Specification PKT-SP-EC-MGCP-I10-040402.

[PKT-SP-MGCP] PacketCableのネットワークベースのコールシグナリングプロトコル仕様PKT-SP-EC-MGCP-I10-040402。

[PKT-SP-PROV] PacketCable MTA Device Provisioning Specification PKT-SP-PROV-I10-040730.

[PKT-SP-PROV]のPacketCable MTAデバイスプロビジョニング仕様PKT-SP-PROV-I10-040730。

10.2. Informative References
10.2. 参考文献

[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart, "Introduction and Applicability Statements for Internet-Standard Management Framework", RFC 3410, December 2002.

[RFC3410]ケース、J.、マンディ、R.、パーテイン、D.、およびB.スチュワート、 "インターネット標準の管理フレームワークのための序論と適用性声明"、RFC 3410、2002年12月。

[RFC3435] Andreasen, F. and B. Foster, "Media Gateway Control Protocol (MGCP) Version 1.0", RFC 3435, January 2003.

[RFC3435]アンドレア、F.およびB.フォスター、 "メディアゲートウェイコントロールプロトコル(MGCP)バージョン1.0"、RFC 3435、2003年1月。

[RFC5234] Crocker, D., Ed., and P. Overell, "Augmented BNF for Syntax Specifications: ABNF", STD 68, RFC 5234, January 2008.

"構文仕様のための増大しているBNF:ABNF" [RFC5234]クロッカー、D.、エド、およびP. Overell、。、STD 68、RFC 5234、2008年1月。

[RFC4682] Nechamkin, E. and J-F. Mule, "Multimedia Terminal Adapter (MTA) Management Information Base for PacketCable- and IPCablecom-Compliant Devices", RFC 4682, December 2006.

[RFC4682] Nechamkin、E及びJ-F。ミュール、「PacketCable-のためのマルチメディア端末アダプタ(MTA)管理情報ベースとIPCablecom準拠デバイス」、RFC 4682、2006年12月。

[ETSI-TS-101-909-4] ETSI TS 101 909-4:"Access and Terminals (AT); Digital Broadband Cable Access to the Public Telecommunications Network; IP Multimedia Time Critical Services; Part 4: Network Call Signaling Protocol".

[ETSI-TS-101-909-4] ETSI TS 101 909-4:「アクセスおよびターミナル(AT);公衆電気通信網へのデジタルブロードバンドケーブルアクセス、IPマルチメディアタイムクリティカルサービス;パート4:ネットワークコール・シグナリング・プロトコル」 。

[ETSI-TS-101-909-9] ETSI TS 101 909-9:"Access and Terminals (AT); Digital Broadband Cable Access to the Public Telecommunications Network; IP Multimedia Time Critical Services; Part 9: IPCablecom Network Call Signalling (NCS) MIB Requirements".

[ETSI-TS-101-909-9] ETSI TS 101 909から9:「アクセスおよびターミナル(AT);公衆電気通信網へのデジタルブロードバンドケーブルアクセス、IPマルチメディアタイムクリティカルサービス;パート9:IPCablecomネットワークコールシグナリング( NCS)MIBの要件」。

[ETSI-EN-300-001] ETSI EN 300-001 V1.5.1 (1998-10):"European Standard (Telecommunications series) Attachments to Public Switched Telephone Network (PSTN); General technical requirements for equipment connected to an analogue subscriber interface in the PSTN; Chapter 3: Ringing signal characteristics (national deviations are in Table 3.1.1)".

[ETSI-EN-300から001] ETSI EN 300から001 V1.5.1(1998年から1910年):「欧州規格(電気通信シリーズ)添付公衆への交換電話網(PSTN)、アナログ加入者に接続された機器のための一般的な技術要件PSTNにおけるインタフェース;第3章:リンギング信号特性(国立偏差が表3.1.1です)」。

[ETSI-EN-300-324-1] ETSI EN 300 324-1 V2.1.1 (2000-04):"V Interfaces at the digital Loop Exchange (LE); V5.1 interface for the support of Access Network (AN); Part 1: V5.1 interface specification".

[ETSI-EN-300-324-1] ETSI EN 300 324-1 V2.1.1(2000-04):デジタルループ交換(LE)の「Vインタフェース、アクセスネットワークをサポートするためのV5.1インタフェース(AN );パート1:V5.1インタフェース仕様」。

[ETSI-EN-300-659-1] ETSI EN 300 659-1: "Public Switched Telephone Network (PSTN); Subscriber line protocol over the local loop for display (and related) services; Part 1: On hook data transmission".

[ETSI-EN-300-659-1] ETSI EN 300 659から1:「は:フックデータ伝送に部分1;表示(および関連する)サービスのためのローカルループ上加入者線プロトコル公衆交換電話網(PSTN)」 。

[ITU-T-E.180] ITU-T E.180: "Various Tones Used in National Networks, Supplement 2 to Recommendation E.180".

[ITU-T-E.180] ITU-T E.180: "ナショナル・ネットワークで使用される様々なトーン、勧告E.180補足2"。

[ETSI-TR-101-183] ETSI TR-101-183: "Public Switched Telephone Network (PSTN) Analogue Ringing Signals".

[ETSI-TR-101から183] ETSI TR-101から183: "公衆交換電話網(PSTN)アナログリンギング信号をスイッチ"。

Authors' Addresses

著者のアドレス

Gordon Beacham Motorola, Inc. 6450 Sequence Drive, Bldg. 1 San Diego, CA 92121, USA

ゴードン・ビーチャムモトローラ社6450シーケンスドライブ、ビル。 1サンディエゴ、CA 92121、USA

Phone: +1 858-404-2334 EMail: gordon.beacham@motorola.com

電話:+1 858-404-2334電子メール:gordon.beacham@motorola.com

Satish Kumar Mudugere Eswaraiah Texas Instruments India (P) Ltd., Golf view, Wind Tunnel Road Murugesh Palya Bangalore 560 017, INDIA

サティシュ・クマールMudugere Eswaraiahテキサス・インスツルメンツインド(P)有限公司、ゴルフビュー、風洞道路Murugesh Palyaバンガロール560 017、インド

Phone: +91 80 5269451 EMail: satish.kumar@ti.com

電話:+91 80 5269451 Eメール:satish.kumar@ti.com

Sumanth Channabasappa Cable Television Laboratories, Inc. 858 Coal Creek Circle, Louisville, CO 80027, USA

スーマンスChannabasappaケーブルテレビラボラトリーズ社858コールクリークサークル、ルイビル、CO 80027、USA

Phone: +1 303-661-3307 EMail: Sumanth@cablelabs.com

電話:+1 303-661-3307電子メール:Sumanth@cablelabs.com

Full Copyright Statement

完全な著作権声明

Copyright (C) The IETF Trust (2008).

著作権(C)IETFトラスト(2008)。

This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights.

この文書では、BCP 78に含まれる権利と許可と制限の適用を受けており、その中の記載を除いて、作者は彼らのすべての権利を保有します。

This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY, THE IETF TRUST AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

この文書とここに含まれている情報は、基礎とCONTRIBUTOR「そのまま」、ORGANIZATION HE / SHEが表すまたはインターネットSOCIETY、(もしあれば)を後援し、IETF TRUST ANDインターネットエンジニアリングタスクフォース放棄ALLに設けられています。保証は、明示または黙示、この情報の利用および特定目的に対する権利または商品性または適合性の黙示の保証を侵害しない任意の保証がこれらに限定されません。

Intellectual Property

知的財産

The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79.

IETFは、本書またはそのような権限下で、ライセンスがたりないかもしれない程度に記載された技術の実装や使用に関係すると主張される可能性があります任意の知的財産権やその他の権利の有効性または範囲に関していかなる位置を取りません利用可能です。またそれは、それがどのような権利を確認する独自の取り組みを行ったことを示すものでもありません。 RFC文書の権利に関する手続きの情報は、BCP 78およびBCP 79に記載されています。

Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr.

IPRの開示のコピーが利用できるようにIETF事務局とライセンスの保証に行われた、または本仕様の実装者または利用者がそのような所有権の使用のための一般的なライセンスまたは許可を取得するために作られた試みの結果を得ることができますhttp://www.ietf.org/iprのIETFのオンラインIPRリポジトリから。

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf-ipr@ietf.org.

IETFは、その注意にこの標準を実装するために必要とされる技術をカバーすることができる任意の著作権、特許または特許出願、またはその他の所有権を持ってすべての利害関係者を招待します。 ietf-ipr@ietf.orgのIETFに情報を記述してください。